Andreas Brenner

Andreas Brenner

Auto-generated profile, based on publicly available information

Andreas Brenner

Fraunhofer Institute for Laser Technology ILT, Aachen, Germany

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2021 in Journal of Materials Processing Technology
Verified
Journal Article
Open access
ASAstrid Sassmannshausen
Astrid Sassmannshausen
ABAndreas Brenner
Andreas Brenner
JFJohannes Finger
Johannes Finger

1 September 2022 in Optical Engineering
Verified
Journal Article
Open access
PDF file
MZMilena Zuric
Milena Zuric
ABAndreas Brenner
Andreas Brenner
By means of the ultrashort pulse (USP) laser processing, surfaces of a wide variety of materials can be manipulated with micrometer precision and a negligible thermal load. Metals can therefore be structured almost melt-free, allowing USP laser processing to address numerous applications in many industrial sectors. The diversity of applications as well as processable materials and alloys continuously require new process development. However, this development is highly time-consuming due to the complexity of the USP laser processing itself. In addition, even the industrial grade machining often takes a long time. A prominent example is the several of days lasting manufacturing of steel tools for car dashboard molding. The resulting need for detection and elimination of any instabilities as early as possible increases the importance of monitoring of surface properties in parallel to the machining. However, the constant requirement for more efficiency leads to a further acceleration of the processing. This in turn complicates the online monitoring as it requires an increase in sampling rates with simultaneously maintaining a high spatial resolution.

1 August 1999 in Metrologia
Verified
Journal Article
Closed access
PDF file
SRS P Robinson
S P Robinson
GGG J Green
G J Green
RPR C Preston
R C Preston
LPL Peirlinckx
L Peirlinckx
LKL Kofoed
L Kofoed
DKD Krüger
D Krüger
This paper describes a European comparison of free-field hydrophone calibrations in the frequency range 10 kHz to 315 kHz. A total of twelve participants from seven European countries took part by calibrating three reference hydrophones, with project coordination provided by the National Physical Laboratory (NPL), UK. The agreement between the results was generally encouraging, with a majority of the results lying within 1 dB of the grand mean. However, some large variations were observed, and the uncertainties in the calibrations were typically underestimated by the participants, with the maximum differences from the grand means almost invariably exceeding the quoted overall uncertainties. A discussion is given of possible reasons for the disagreement, and of useful further work identified as a result of this comparison.

1 January 1995
Verified
Conference Paper
Closed access
ABA.R. Brenner
A.R. Brenner
KEK. Eck
K. Eck
GEGeorge Engelhard
George Engelhard
TNT.G. Noll
T.G. Noll

1 January 2007
Verified
Conference Paper
Closed access
DCD. Cerutti-Maori
D. Cerutti-Maori
JKJ. Klare
J. Klare
WBW. Burger
W. Burger
ABA.R. Brenner
A.R. Brenner
JEJ.H.G. Ender
J.H.G. Ender
This paper presents some Scan-MTI results, which were obtained with the SAR-GMTI system PAMIR developed at FGAN-FHR. The Scan-MTI mode was designed to rapidly monitor wide areas for ground moving targets. The scan operation enables detection of targets from different aspect angles with a high revisit rate. This mode is particularly adapted to perform an efficient traffic monitoring, as well.

1 January 2012
Verified
Book Chapter
Closed access
PDF file
ABAndreas Brenner
Andreas Brenner
"Leben leben und Leben machen. Die Synthetische Biologie als Herausforderung für die Frage nach dem Lebensbegriff" published on 01 Jan 2012 by mentis.