Gernot A. Pacher

Gernot A. Pacher

Auto-generated profile, based on publicly available information

Gernot A. Pacher

Polymer Competence Center Leoben GmbH (PCCL) , Leoben , Austria

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2014 in Polymer Testing
Verified
Journal Article
Open access
DGDieter P. Gruber
Dieter P. Gruber
JMJohannes Macher
Johannes Macher
DHDietmar Haba
Dietmar Haba
GBGerald R. Berger
Gerald R. Berger
GPGernot Pacher
Gernot Pacher
WFWalter Friesenbichler
Walter Friesenbichler
The aim of this work is to present a novel methodology for fast evaluation of the visual perceptibility of sink marks on surfaces of injection molded parts. Based on previous research work on the detection of surface defects, a new model for the calculation of the visibility of sink marks from CCD-images was developed. A new calculated surface model function was used to determine the amplitudes of the second derivatives (ASD) as a measure for the visual perceptibility of sink marks. This model parameter is quickly calculable and, therefore, ideally suited to application in a machine vision system used for in-line quality inspection. In order to test the model parameter, injection molding parts were produced using predefined processing conditions, and the influence of process parameter variation on the visual perceptibility of the sink marks was evaluated

1 September 2011 in Polymer Testing
Verified
Journal Article
Closed access
DGDieter P. Gruber
Dieter P. Gruber
GBGerald Berger
Gerald Berger
GPGernot Pacher
Gernot Pacher
WFWalter Friesenbichler
Walter Friesenbichler

1 April 2014 in Polymer Testing
Verified
Journal Article
Closed access
JMJohannes Macher
Johannes Macher
DGDieter P. Gruber
Dieter P. Gruber
TAThomas Altenbuchner
Thomas Altenbuchner
GPGernot A. Pacher
Gernot A. Pacher
GBGerald R. Berger
Gerald R. Berger
WFWalter Friesenbichler
Walter Friesenbichler

1 October 2014 in Polymer Testing
Verified
Journal Article
Closed access
JMJohannes Macher
Johannes Macher
DGDieter P. Gruber
Dieter P. Gruber
TAThomas Altenbuchner
Thomas Altenbuchner
GPGernot A. Pacher
Gernot A. Pacher
GBGerald Berger-Weber
Gerald Berger-Weber
WFWalter Friesenbichler
Walter Friesenbichler

1 January 2014 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
GPG. A. Pacher
G. A. Pacher
GBGerald Berger-Weber
Gerald Berger-Weber
WFWalter Friesenbichler
Walter Friesenbichler
DGDieter P Gruber
Dieter P Gruber
JMJohannes Macher
Johannes Macher
To gain extended knowledge on the flow behavior of polymer melts during filling phase of the injection molding process, an injection mold featuring complex sensor technology was developed. Three triple-combined FOS MTPS408 cavity sensors (FOS Messtechnik GmbH) are aligned along the flow path of a plate-shaped cavity. Each sensor features an infrared detector, a type K thermocouple, and a piezo-electric pressure detector. This configuration enables the local and transient recording of melt temperature, mold temperature and cavity pressure near gate, part center and end of part simultaneously. Averaged melt velocities are determined by evaluating the differing times of the rising edges of the infrared sensors. Local melt velocities and viscosities are calculated at each sensor position by evaluation of the gradients of temperature and pressure. Moreover, the used injection mold is equipped with RHCM technologies to additionally influence the mold surface temperature and hence the filling of the cavity. The specimens are plate-shaped parts having cut-outs and ribs similar to geometries found in numerous industrial applications such as cover panels. The application of this in-mold sensor concept provides novel possibilities for the systematic in-line analysis and evaluation of process-parameters in injection molding. Further studies will be carried out to connect the process-specific properties to the specimen morphology; aiming at controlling morphology by adjusting process parameters.

1 January 2014 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
GBGerald Berger-Weber
Gerald Berger-Weber
GPG. A. Pacher
G. A. Pacher
APA. Pichler
A. Pichler
WFWalter Friesenbichler
Walter Friesenbichler
DGDieter P Gruber
Dieter P Gruber
Dynamic mold surface temperature control was examined for its influence on the warpage. A test mold, featuring two different rapid heat cycle molding (RHCM) technologies was used to manufacture complex plate-shaped parts having different ribs, varying thin-wall regions, and both, circular and rectangular cut-outs. The mold's nozzle side is equipped with the areal heating and cooling technology BFMOLD®, where the heating/cooling channels are replaced by a ball-filled slot near the cavity surface flooded through with hot and cold water sequentially. Two local electrical ceramic heating elements are installed into the mold's ejection side. Based on a 23 full-factorial design of experiments (DoE) plan, varying nozzle temperature (Tnozzle), rapid heat cycle molding temperature (TRHCM) and holding pressure (pn), specimens of POM were manufactured systematically. Five specimens were examined per DoE run. The resulting warpage was measured at 6 surface line scans per part using the non-contact confocal topography system FRT MicroProf®. Two warpage parameters were calculated, the curvature of a 2nd order approximation a, and the vertical deflection at the profile center d. Both, the influence strength and the acting direction of the process parameters and their interactions on a and d were calculated by statistical analysis. Linear mathematical process models were determined for a and d to predict the warpage as a function of the process parameter settings. Finally, an optimum process setting was predicted, based on the process models and Microsoft Excel GRG solver. Clear and significant influences of TRHCM, pn, Tnozzle, and the interaction of TRHCM and pn were determined. While TRHCM was dominant close to the gate, pn became more effective as the flow length increased.