9 March 2020 in International Journal of Numerical Modelling: Electronic Networks, Devices and Fields
12 June 2019 in International Transactions on Electrical Energy Systems
26 November 2017 in Electric Power Components and Systems
This paper deals with an optimal hybrid fuzzy-Proportional Integral Derivative (fuzzy-PID) controller optimized by hybrid differential evolution–Grey Wolf optimization algorithm for automatic generation control of an interconnected multi-source power system. Here a two area system is considered; each area is provided with three types of sources namely a thermal unit with reheat turbine, a hydro unit and a gas unit. The dynamic performance of the system is analyzed under two cases: with AC tie-line and with AC-DC tie-line. The efficiency and effectiveness of the proposed controller is substantiated equally in the two cases. The sturdiness of the system is proved by varying the values of the system parameters. The supremacy of the recommended work is additionally ascertained by comparison with the recently published results like differential evolution optimized PID Controller and hybrid Local Unimodal Sampling-Teaching Learning based Optimization (LUS-TLBO) optimized fuzzy-PID controller. The dynamic performance of the system is observed in terms of settling time, peak overshoot and peak undershoot. Finally the analysis is extended by applying the proposed control technique in two different models namely (i) A three area unequal thermal system considering proper generation rate constraints (GRC) and (ii) A three area hydro-thermal system with mechanical hydro governor. These test results reveal the adaptability of the proposed method in multi-area interconnected power system.
11 February 2019 in International Journal of Electrical Engineering & Education
The operation and control of the modern power system has become complex and difficult due to the incessant penetration of nonconventional energy sources integrated to the power grid and the structural variation of power system with continuing escalation of power demand in recent years. This entails the implementation of intelligent control strategy for satisfactory operation of the power system. Hence, a fractional order fuzzy proportional integral derivative (FOFPID) controller is suggested in this article for automatic generation control of two unequal area interconnected power system with diverse generating units such as thermal, hydro, diesel and wind power plants. The dynamic performance of the system is investigated by using proportional integral derivative (PID), fractional order PID (FOPID), fuzzy PID (FPID) and fractional order fuzzy PID (FOFPID) controllers separately. The parameters of these controllers are optimised by using ant lion optimiser algorithm with integral time absolute error as the objective function. The supremacy of the proposed controller is established by contrasting the results with FPID, FOPID and PID controllers. It is also observed that FPID controller gives superior result than PID and FOPID controllers. Further it is found that the result of FOPID controller is better than the integer order PID controller. Finally robustness analysis is performed to confirm the robustness of the proposed controller against parametric variations and random loading of the system.
1 January 2017 in Cogent Engineering
In this research paper a novel cascaded PD-Fuzzy-PID controller is recommended for a conventional hybrid-source unified power system for automatic generation control. The optimization of scaling parameters of the suggested PD-Fuzzy-PID controller is done by hybrid Grey Wolf Optimization-Teaching Learning Based Optimization (GWO-TLBO) technique. A sudden disturbance of 0.01 p.u. is considered in area 1 and ITAE is taken as the evaluative function in the recommended optimization process. The proposed work considers three different sources of generating systems namely, a hydro, a gas and a reheat thermal unit. Both AC tie-line and AC-DC tie-line is considered in analyzing the dynamic performances of the system. The robustness and sensitiveness of the proposed controller are further put to test for random load variations and nominal parameter variations. Analysis of the dynamic characteristics of the system is executed considering a number of time response specifications like settling time, peak overshoots and undershoots. During the analysis the optimum specifications obtained by the recommended technique are compared with some pre-published results in order to prove the supremacy of this novel controller over existing controllers. Further, the frequency stability of the system is improved by employing an UPFC in the system.
15 March 2022 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Optimal novel Self-tuning Fuzzy-PI (STFPI) controller has been introduced to analyze the LFC (Load Frequency Control) in a multi-unit unified system. The finest constraints of this suggested STFPI controller are found using quasi-opposition-based Jaya (QOB Jaya) algorithm. The investigation is performed over a two area multi-generation unified system. The examined model considers both renewable-type (wind) and conventional-type (thermal, diesel, & hydro) generating sources. The efficacy of the proposed controller is confirmed by (i) varying the size of loading, (ii) changing the constraints of designed system, and (iii) injecting arbitrary loading into the power system. It has been derived that the value of the objective function (Integral Time Absolute Error) with QOB Jaya tuned STFPI controller is improved by 95.44%, 85.17%, and 50% as compared to PSO-tuned PID Controller, QOB Jaya-tuned FPI Controller, and Jaya-tuned STFPI Controller, respectively. The supremacy of the projected controller is proved by doing comparisons among the responses of fuzzy-PI controller and a pre-published outcome such as PSO (particle swarm optimization) tuned PID (proportional-integral-derivative) controller.