This study examines the failure laws of soft and hard interlayer overlying rocks and the development height of the water‐conducting fracture zone in a gently inclined super‐thick coal seam at the Qifeng coal mine, Shanxi. The overlying rocks above the working face were classified into four typical structural types: soft‐hard‐soft‐hard, hard‐soft‐hard‐soft, soft‐soft‐hard‐hard, and hard‐hard‐soft‐soft. First, the failure laws of these four types of overlying rock structures were studied theoretically. Theoretical analysis revealed that different overlying rock structures form different composite rock beams that move synchronously after coal excavation. Numerical simulation using FLAC3D showed that the overburden failure does not change linearly but forms different combined rock beams according to the different overburden structures, resulting in a step change. The soft–soft–hard–hard overburden structure exhibits the largest damage extent, while the soft–hard–soft–hard overburden structure results in the highest damage height. When the hard rock above the coal seam is closer to the stope, the influence of the mining stress is greater, leading to stress concentration at the junction of soft and hard rocks. Three methods—theoretical analysis, numerical simulation, and field measurement—were used to study the overlying rock failure law and the development height of the water‐conducting fracture zone of the 51408 working face of the Qifeng Coal industry. The results show that the guiding height of the 51408 working face of the Qifeng Coal industry is 120.12, 103.6, 113.2, and 116.1 m for the four overlying rock structures. The maximum measured height of 116.1 m was considered the development height of the water‐conducting fracture zone. The field‐measured results are consistent with those obtained by theoretical calculation and numerical simulation, confirming the accuracy of the theoretical analysis and numerical simulation and providing a basis for water prevention and control of the roof of gently tilting super‐thick coal seams.
With the continuous advancement of coal mining technology, the mining height and length of working faces in China have increased, and ultra‐long fully mechanized mining faces with large‐mining heights have become the prevailing layout trend in modern coal mines. As the working‐face dimensions increase, the range of overburden failure after coal seam extraction expands, resulting in an increased intensity of ground pressure manifestations. Consequently, the conventional method for determining the rated working resistance of hydraulic supports no longer applies. Therefore, investigating the overburden failure mechanism in ultra‐long fully mechanized mining faces with large‐mining heights is of great importance. Considering the 6306 working face of the Sihe Coal Mine as the research background, theoretical analysis, numerical simulation, and field measurements were employed to analyze the overburden failure range and structural characteristics under different face lengths. The results indicate that, during the mining process of the 6306 working face, the overburden is controlled by key strata and hard rock layers, forming a composite structure of “cantilever beam + voussoir beam.” On the basis of a stress‐transfer model of the composite structure, an analysis demonstrated that, when the working‐face length reached 320 m, the overburden failure range exerting a significant influence on hydraulic supports in the large‐mining‐height ultra‐long working face extended to 40.3 m, and the corresponding required working resistance of the hydraulic supports was calculated as 11,972 kN. Field ground pressure monitoring confirmed that hydraulic supports with a capacity of 12,000 kN could meet the roof control requirements, thus ensuring safe and efficient mining of the ultra‐long fully mechanized face with a large‐mining height.