Duraisamy Sarathkumar

Duraisamy Sarathkumar

Auto-generated profile, based on publicly available information

Duraisamy Sarathkumar

Kongu Engineering College

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
SDSarathkumar Duraisamy
Sarathkumar Duraisamy
SVSrini Vasan
Srini Vasan
KMKarthikeyan Murugan
Karthikeyan Murugan
RRRaymon Antony Raj
Raymon Antony Raj
The study lowers the environmental risk by combining biodegradable adsorbents with stronger adsorption. This work uses two distinct kinds of adsorbents, namely Polyaniline (PANI) coated Kappa Cotton (KPC) and activated clay-biopolymer, Bentonite (aB) composite and Chitosan (CTN), to recover the aged transformer oil (aTO). Using the Box-Behnken (BB) design paired response surface method (RSM) approach, an experimental sequence was created to determine the optimal ratio of the adsorbent materials. The aTO was supplemented with the homogenized aB-CTN material (A*) and PANI-coated-KPC (B*) materials. After optimization, it was found that the optimal values for the input variables for the dielectric breakdown voltage and dielectric dissipation factor were A* = 1.76 g, B* = 1.28 g, temperature = 78.9 °C, while stirring duration = 3 h was kept constant. After treatment under ideal conditions, it was found that aTO1 had dielectric characteristics of 46.6 kV and 0.0020 dissipation factor, which are equivalent to those of laboratory studies conducted in triplicate with a 2.5 percent error. They demonstrate that aTO exhibits an outstanding dielectric response when the optimal proportion of the process variables (A* and B*) is used. The removal of impurities from aTO has considerably enhanced its dielectric properties, as seen by the CIE chromaticity coordinates, XRD analysis, UV responses, and FTIR analyses. The material’s ability to sorb dyes, polar impurities, and heavy metal ions is significantly increased by the expanded active sites of A* and B*.

22 July 2022 in Biomass Conversion and Biorefinery
Verified
Journal Article
Closed access
PDF file
SDSarathkumar Duraisamy
Sarathkumar Duraisamy
SMSrinivasan Murugesan
Srinivasan Murugesan
MPManikandan Palanichamy
Manikandan Palanichamy
RRRaymon Antony Raj
Raymon Antony Raj

1 February 2021 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
DSD Sarathkumar
D Sarathkumar
MSM Srinivasan
M Srinivasan
ASAlbert Alexander Stonier
Albert Alexander Stonier
RSRavi Samikannu
Ravi Samikannu
NDNarasimha Rao Dasari
Narasimha Rao Dasari
RRRaymon Antony Raj
Raymon Antony Raj
The various advanced technologies incorporated in the existing power system to operate in smarter and to provide continuity of power supply without any disturbances. Still, it was few threats that disrupting the electrical network to manage the power demand such as: complexity of the power grid; vulnerability to faults; energy efficiency; and renewable energy integration. The above challenges indicate the perception of smart grid (SG). The smart grid design is economic, competent, intelligent and secured grid was needed to manage the above-mentioned issues. Self-healing is the most essential characteristics of a smart grid. The implementation of self-healing control strategy in the smart grid is one of the prolong challenge. It is the capability of the power system network to restore naturally the network when the fault occurs. It gives primary assurance to the smart grid protection. Apart from this, the implementation of various control strategies assist accomplishing the safe functioning, enhancing the stability of the grid. This paper presents the self-healing control strategy in the context of smart grid power systems. The significant advancements developed in the transmission, distribution, micro grid as a result of power electronics converters presented. Then, the information and communication technologies, software tools and measurements which can be employed for winning crucial smart grid self-healing action will be discussed.

1 February 2021 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
DSD Sarathkumar
D Sarathkumar
MSM Srinivasan
M Srinivasan
ASAlbert Alexander Stonier
Albert Alexander Stonier
RSRavi Samikannu
Ravi Samikannu
NDNarasimha Rao Dasari
Narasimha Rao Dasari
RRRaymon Antony Raj
Raymon Antony Raj
Increasing the technological developments of smart sensors, Information and communication tools (ICT) the traditional electric power systems have emerged with the improvement of Smart grids. Smart grid is defined as a modernized electric power grid with the integration of ICT tools and distributed generation (DG) resources into existing power system to provide continuous, stable and quality of power to all. Present smart grid electric power system network, the fault identification and mitigation is one of very critical task. Current power system structure transformed remarkably due to extension and integration of enormous amount of DG resources at delivery side. To confront the limitations of smart grids, existing fault identification and mitigation methods requires immoderate revision by making use of excellent facilities and tools. That will be useful to attain automation in fault detection, enhance the voltage stability, transient stability, and self-healing ability to perform the desired task. This paper is going to presents a detailed survey about target on various types of faults and fault detection methods in smart grids.

1 February 2014
Verified
Conference Paper
Closed access
MBM. Arun Bhaskar
M. Arun Bhaskar
DSD. Sarathkumar
D. Sarathkumar
MAM. Anand
M. Anand
Today's power industry faces lot of problem in maintaining the voltage stability and system stability. Installation of compensating devices proves to be a solution. But the cost of compensating devices adds burden to the consumer consumption changes. Hence a new method of utilizing fuel cell a renewable energy source as a compensating device is proposed in this work. Fuel cell is modelled as Staic Synchronous Compensator (STATCOM) - a FACTS compensating device. The ability of the fuel cell based STATCOM in improving the system voltage stability and transient stability after a fault condition is also done in MATLAB simulink environment.

17 July 2023 in Frontiers in Materials
Verified
Journal Article
Open access
DSD. Sarathkumar
D. Sarathkumar
GMGian Carlo Montanari
Gian Carlo Montanari
RSR. Sarathi
R. Sarathi
MSM. Srinivasan
M. Srinivasan
RKR. Karthik
R. Karthik
JSJ. Sivadasan
J. Sivadasan
Using mineral oil (MO) derived from petroleum, e.g., transformer insulation, raises environmental risk and affects sustainability. Due to its affordability and easy availability, MO will ineluctably be preferred over other biodegradable oils. Therefore, tools must be developed to recover aged MO, extend the life cycle, and increase its sustainability. The work presented here is aimed at the investigation of the electrical insulation properties of thermally-aged recovered-aged mineral oil (RAMO), as well as of aged cellulose pressboard impregnated by fresh mineral oil (FMO), aged mineral oil (AMO), and RAMO. The AMO is recovered using the combined adsorbents, A* and B*, which are Chitosan-activated Bentonite (CTN-aB) and Polyaniline coated Kapok Fibre (PANI-c-KPF) mix. According to FTIR, the recovered oil, RAMO, displays less C=C double bonds and carbonyl vibrations at 140°C, indicating lower oil ageing compared to AMO. The distribution of the crystalline and amorphous peaks is uniform for aged oil-impregnated pressboard (PB) with FMO and RAMO. Overall, it has been discovered that PB is impregnated with RAMO, resulting in an extended lifetime for the solid insulation. As a result, the increase in emissions slows down, and global sustainability targets are met.