Compared with traditional single L-type filters, LCL filters for three-phase grid-connected inverters can suppress the switching voltage and current ripple better, thus reducing harmonic pollution to the power grid. However, the increase in system order also makes it difficult to control the system. To solve the problems of complex model and severe coupling of LCL filter in the d-q coordinate system, the decoupling control of current inner loop by the linear extended state observer (LESO) was proposed based on the analysis of mathematical model of grid-connected inverter with an LCL filter. Moreover, given the relatively low speed of system response in traditional active disturbance rejection control (ADRC), the tracking differentiator (TD) was removed, and the nonlinear control law was replaced with the PI controller. Compared with the conventional feedforward decoupling method, the reasonably designed LESO used in this work can not only realize decoupling control of the original system to improve its performance, but also save the cost of sensor and achieve a better decoupling effect. The effectiveness of the proposed current control strategy was verified by experimental results.
In the traditional model predictive control(T-MPC), only inverter side current of LCL inverter is treated as a control target. Grid side current is controlled indirectly by controlling the inverter side current directly. The control performance of the algorithm can be further improved. In this paper, a complete model predictive control algorithm(C-MPC) which take the grid side current as control target directly is proposed. The equivalent mathematical model and the equivalent circuit model are established based on active damping of capacitive current proportional feedback, then system predictive control model is established by the equivalent mathematical model and the circuit model. In order to make the output current track the directive current accurately at the next moment, the output voltage vector needed at this moment is calculated by the predictive control model. Finally, the required voltage vector is reproduced through space vector modulation(SVM). The simulation results and experimental measurements verify the developed control schemes and show high quality of grid side current (low THDi value).