29 December 2023 in European Journal of Nuclear Medicine and Molecular Imaging
2 May 2023 in Physics in Medicine & Biology
Objective . Phantoms of the International Commission on Radiological Protection provide a framework for standardized dosimetry. The modeling of internal blood vessels—essential to tracking circulating blood cells exposed during external beam radiotherapy and to account for radiopharmaceutical decays while still in blood circulation—is, however, limited to the major inter-organ arteries and veins. Intra-organ blood is accounted for only through the assignment of a homogeneous mixture of parenchyma and blood [single-region (SR) organs]. Our goal was to develop explicit dual-region (DR) models of intra-organ blood vasculature of the adult male brain (AMB) and adult female brain (AFB). Approach . A total of 4000 vessels were created amongst 26 vascular trees. The AMB and AFB models were then tetrahedralized for coupling to the PHITS radiation transport code. Absorbed fractions were computed for monoenergetic alpha particles, electrons, positrons, and photons for both decay sites within the blood vessels and for tissues outside these vessels. Radionuclide S -values were computed for 22 and 10 radionuclides commonly employed in radiopharmaceutical therapy and nuclear medicine diagnostic imaging, respectively. Main results . For radionuclide decays, values of S (brain tissue ← brain blood) assessed in the traditional manner (SR) were higher than those computed using our DR models by factors of 1.92, 1.49, and 1.57 for therapeutic alpha-emitters, beta-emitters, and Auger electron-emitters, respectively in the AFB and by factors of 1.65, 1.37, and 1.42 for these same radionuclide categories in the AMB. Corresponding ratios of SR and DR values of S (brain tissue ← brain blood) were 1.34 (AFB) and 1.26 (AMB) for four SPECT radionuclides, and were 1.32 (AFB) and 1.24 (AMB) for six common PET radionuclides. Significance . The methodology employed in this study can be explored in other organs of the body for proper accounting of blood self-dose for that fraction of the radiopharmaceutical still in general circulation.
1 June 2025 in Journal of Radiological Protection
Estimates of organ-absorbed and committed doses to individuals exposed to radioactive materials via acute inhalation often rely on internal dose coefficients and detector responses from reference human computational models. To achieve more accurate dose assessments to United States Armed Forces service members exposed in-field, computational models with varying morphometric parameters representative of this population are necessary. The International Commission on Radiological Protection (ICRP) Publication 145 provides detailed mesh reference computational phantoms (MRCPs) for adult males and females, with morphometric parameters matched to the 50th percentile. Previously, these phantoms were 2D and 3D scaled to match desired height, mass, and secondary anthropomorphic parameters in the creation of the University of Florida / Memorial Sloan Kettering (UF/MSK) computational phantom library. To achieve body fat percentage targets required for accession into the US Armed Forces, muscle and fat volumes were adjusted accordingly, thus, creating the UF/Department of Defence computational phantom library presented in this study. A comprehensive library of mesh-type computational human phantoms was created, including 57 adult males and 49 adult females with morphometric parameters aligned with United States Armed Forces service members. Phantoms were restricted to a body mass index between 19 and 27.5, with body fat percentages below 26% for males and 36% for females. Specific absorbed fractions were computed for selected source and target combinations, demonstrating how variations in height and body mass influence energy absorption in target regions relative to the ICRP MRCPs. Radiation detector responses were also computed, revealing that higher body masses resulted in decreased registered counts in the detection volume. These findings highlight the importance of incorporating morphometric variability in computational phantoms to achieve more accurate dose assessments and radiation detection responses for United States Armed Forces service members who inhale radioactive materials in-field.
21 November 2025 in Physics in Medicine & Biology
Objective. To develop a comprehensive mesh-based computational human phantom library of adult males and females that span current US body-size distributions. The phantom library was developed jointly between the University of Florida and Memorial Sloan-Kettering Cancer Center and termed the UF/MSK Phantom Library. Approach. Adult phantoms were modeled by rescaling and systematically deforming the International Commission on Radiological Protection Publication 145 mesh-type reference computational phantoms to match heights, body mass, and CDC National Health and Nutrition Examination Survey-derived secondary anthropometric parameters. Low body-mass phantoms underwent uniform two-dimensional scaling of abdominal organs to avoid collision with subcutaneous fat. To accommodate larger body circumferences, a rigging procedure was developed to smoothly deform the limbs while maintaining anatomical realism and preserving tissue. A companion ‘arms-up’ version of the library appropriate for computed tomography (CT) dosimetry simulation was also constructed. A validated CT source term was developed for the Canon Aquilion ONE/GENESIS considering technique factors such as tube voltage, bowtie filter size, and beam collimation, and was used to compute slice-specific organ doses for a subset of library phantoms. Main results. A large library of 186 male and 171 female (357 total) phantoms was created. Standing height ranged from 150–200 cm for males and 150–195 cm for females, and total body mass ranged from 40–150 kg for males and 40–155 kg for females. Simulated CT organ doses varied smoothly with BMI for a fixed phantom height. Significance. The UF/MSK adult phantom library has been constructed with body morphometries representative of the US population. Organ doses computed for phantoms of varying body sizes demonstrate the importance having a morphometrically robust selection of computational phantoms for patient matching. While the immediate application of this library is to expand phantom selection options in MIRDct software ( www.mirdsoft.org ), the library can be further utilized in other applications including radiopharmaceutical, radiography, fluoroscopy, and radiotherapy organ dose reconstructions.
26 July 2021 in Journal of Applied Clinical Medical Physics
The aim of this report is to present the root cause analysis on failed patient-specific quality assurance (QA) measurements of pencil beam scanning (PBS) protons; referred to as PBS-QA measurement. A criterion to fail a PBS-QA measurement is having a 94%, 94 to >88%, and <88% were 93.6%, 5.6%, and 0.8%, respectively. The percentage of failed measurements with a 3% per mm dose gradient with respect to depth on the failed measurements. We utilized a 2D/three-dimensional (3D) gamma index analysis toolkit to investigate the effect of depth dose gradient. By utilizing this 3D toolkit, 43.1% of the failed measurements were improved. A feature among measurements that remained sub-optimal after re-analysis was a sharp >3% per mm lateral dose gradient that may not be well handled using the detector size of 5.0 mm in-diameter. An analysis of the sampling of finite size detectors using one-dimensional (1D) error function showed a large dose deviation at locations of low-dose areas between two high-dose plateaus. User error, large depth dose gradient, and the effect of detector size are identified as root causes. With the mitigation of the root causes, the goals of patient-specific QA, specifically detecting actual deviation of beam delivery or identifying limitations of the dose calculation algorithm of the treatment planning system, can be directly related to failure of the PBS-QA measurements.
19 June 2025 in Physics in Medicine & Biology
Objective. To develop a computational framework coupling multiscale vascular models of the human liver for improved radiation dosimetry calculations that clearly distinguish the absorbed dose to tissue parenchyma and that to its blood content at all spatial scales. This framework thus addresses limitations of homogeneous blood/tissue organ models in present use in radiopharmaceutical therapy. Approach. High-fidelity tetrahedral mesh models of liver vasculature were constructed at two spatial scales. At the macroscale, detailed hepatic arterial, venous, and portal venous networks were generated within reference adult male and female computational phantoms. At the microscale, a classical hexagonal liver lobule model incorporating sinusoids, bile compartments, and cellular components was developed. A mathematical framework was further developed to couple Monte Carlo radiation transport results across these spatial scales, enabling comprehensive dosimetric calculations for radiation dose to both blood and parenchymal tissues. Main Results. The coupled model system successfully accounted for the entire blood content of the liver, with approximately 31% represented in macroscale vessels (⩾100 μm diameter) and 69% within microscale structures. Specific absorbed fractions were computed for monoenergetic photons, electrons, and alpha particles, demonstrating reciprocity between blood-to-parenchyma and parenchyma-to-blood crossfire. Reference S-values were computed for 22 therapeutic and 11 diagnostic radionuclides, providing the first comprehensive dataset for blood-specific and parenchyma-specific internal dosimetry calculations in the liver. Significance. This work establishes a novel framework for multi-scale radiation transport calculations in vascularized organs, enabling separate tracking of blood and parenchymal tissue doses. The methodology has immediate applications in improving dose calculations for radiopharmaceutical therapies, Y-90 microsphere radioembolization treatment, and analysis of blood dose during external beam radiotherapy. The approach can be readily adapted for other vascularized organs, representing a significant advancement in radiation dosimetry accuracy for both therapeutic and diagnostic applications by fully and independently accounting for organ activity localized within two tissue compartments—organ blood and organ parenchyma.