Altibano Ortenzi

Altibano Ortenzi

Auto-generated profile, based on publicly available information

Altibano Ortenzi

Civil Construction Department (DCCI) State University of Londrina (UEL) Londrina Paraná Brazil

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 June 2016 in Journal of the Brazilian Society of Mechanical Sciences and Engineering
Verified
Journal Article
Closed access
PDF file
AOA. Ortenzi
A. Ortenzi
JCJonas Carvalho
Jonas Carvalho
ACAndrea Corvi
Andrea Corvi

1 January 2021 in Materials Today: Proceedings
Verified
Journal Article
Closed access
LMLarissa Queiroz Minillo
Larissa Queiroz Minillo
BCBruno Cesar de Castro Cardoso
Bruno Cesar de Castro Cardoso
AOAltibano Ortenzi
Altibano Ortenzi

14 September 2020 in Journal of Building Engineering
Verified
Journal Article
Closed access
Paulo Cesar Duarte JuniorPaulo Cesar Duarte Junior
Paulo Cesar Duarte Junior
FNFernando Nakao
Fernando Nakao
AOAltibano Ortenzi
Altibano Ortenzi

1 January 2018 in Journal of Building Engineering
Verified
Journal Article
Closed access
SMShandy Alexandra Morassi
Shandy Alexandra Morassi
JSJúlia Lopes Ribeiro da Silva
Júlia Lopes Ribeiro da Silva
AOAltibano Ortenzi
Altibano Ortenzi

12 March 2014 in Advanced Materials Research
Verified
Journal Article
Closed access
PDF file
AOAltibano Ortenzi
Altibano Ortenzi
ACAndrea Corvi
Andrea Corvi
AVAntonio Virga
Antonio Virga
In this study, three types of filament wound glass fiber reinforced epoxy composite specimens were tested according to the ASTM standards to evaluate preliminary, the acoustic emission wave velocity. The pipe specimens had 300.0 mm of length, 50.5 mm of diameter and 3.5 mm of wall thickness. Ten points were marked over the imaginary central circle on the pipe middle, from zero degree up to 90º with nine divisions of 10º each one and an additional point representing the crossing of plies. Next, there are positioned two collinear acoustic emission (AE) sensors along the length, positioned at 35 mm from middle, axially. After the specimen preparation, took place the HSU-NIELSEN or pencil lead break (PLB) tests to analyze the signal wave time for both sensors, by means of the 0.3mm – 2H graphite lead brake. The results were compared to considering the angular variation and the velocity for each winding angle. It was evident that the procedure above can determine with good precision the variations occurred on the acoustic emission velocity on filament wound composite pipes, regarding the three angular variations compared. This study was the parameter of control to proceed with the acousticemission evaluation over tensile tests in further studies to predict the fatigue and the damage propagation on this typology of laminates.

13 June 2025 in Polymer Composites
Verified
Journal Article
Closed access
CCCamilla Alves Freire da Costa
Camilla Alves Freire da Costa
MCMarcelo Aparecido Chinelatto
Marcelo Aparecido Chinelatto
AOAltibano Ortenzi
Altibano Ortenzi