Filip Schlosser

Filip Schlosser

Auto-generated profile, based on publicly available information

Filip Schlosser

Department of Cardiology, Institute for Clinical and Experimental Medicine, IKEM , Prague

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2025 in EP Europace
Verified
Journal Article
Open access
FSFrédéric Sacher
Frédéric Sacher
ASAndrea Sarkozy
Andrea Sarkozy
HPHelmut Purerfellner
Helmut Purerfellner
ASAlexandra Steyer
Alexandra Steyer
JLJonathan Lyne
Jonathan Lyne
PPPetr Peichl
Petr Peichl
Aims: The feasibility and safety of the lattice-tip catheter for ventricular arrhythmia (VA) ablation in humans remain largely unknown. This study aimed to assess feasibility, safety profile as well as patient outcomes after VA ablation with a lattice-tip catheter in a multicentre European registry. Methods and results: All 18 European centres using the AFFERA system in September 2024 agreed to participate. Clinical, procedural, and follow-up data (minimum 3 months) were systematically collected and analysed. A total of 126 patients (18% female; mean age 59 ± 16 years) underwent VA ablation using the lattice-tip catheter during the inclusion period. Ablation indications included ventricular tachycardia (VT) in 99, premature ventricular complexes (PVCs) in 23, and ventricular fibrillation (VF) in 4 patients. Major and minor acute complications were observed in 7 (6%) and 18 (14%) procedures, respectively. They included thrombo-embolic event (n = 2), major bleeding (n = 2), ventricular fibrillation induction (n = 1), tamponade due to epicardial access (n = 1), and cardiogenic shock due to prolonged VT mapping (n = 1). Within the first month post-procedure, three patients died [from multi-organ failure (n = 2) and sepsis (n = 1)], two had worsening heart failure, one myocardial infarction, one sepsis, and one major gastro-intestinal bleeding. After a mean follow-up of 5.6 ± 3.7 months, absence of recurrence was 78% for PVC, 70% for VT, and 100% for VF. Conclusion: In this complex population with refractory VA, ablation using the lattice-tip catheter appears feasible and relatively safe. In the absence of large, randomized trials, exhaustive registry is of key importance to ensure safety and efficacy of new catheter technologies.

2 July 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
PPPetr Peichl
Petr Peichl
ABAlan Bulava
Alan Bulava
DWDan Wichterle
Dan Wichterle
FSFilip Schlosser
Filip Schlosser
PSPredrag Stojadinovic
Predrag Stojadinovic
JKJosef Kautzner
Josef Kautzner
Aims: A pulsed electric field (PF) energy source is a novel potential option for catheter ablation of ventricular arrhythmias (VAs) as it can create deeper lesions, particularly in scarred tissue. However, very limited data exist on its efficacy and safety. This prospective observational study reports the initial experience with VA ablation using focal PF. Methods and results: The study population consisted of 44 patients (16 women, aged 61 ± 14years) with either frequent ventricular premature complexes (VPCs, 48%) or scar-related ventricular tachycardia (VT, 52%). Ablation was performed using an irrigated 4 mm tip catheter and a commercially available PF generator. On average, 16 ± 15 PF applications (25 A) were delivered per patient. Acute success was achieved in 84% of patients as assessed by elimination of VPC or reaching non-inducibility of VT. In three cases (7%), a transient conduction system block was observed during PF applications remotely from the septum. Root analysis revealed that this event was caused by current leakage from the proximal shaft electrodes in contact with the basal interventricular septum. Acute elimination of VPC was achieved in 81% patients and non-inducibility of VT in 83% patients. At the 3-month follow-up, persistent suppression of the VPC was confirmed on Holter monitoring in 81% patients. In the VT group, the mean follow-up was 116 ± 75 days and a total of 52% patients remained free of any VA. Conclusion: Pulsed electric field catheter ablation of a broad spectrum of VA is feasible with acute high efficacy; however, the short-term follow-up is less satisfactory for patients with scar-related VT.

31 October 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
PPPetr Peichl
Petr Peichl
DWDan Wichterle
Dan Wichterle
FSFilip Schlosser
Filip Schlosser
PSPredrag Stojadinovic
Predrag Stojadinovic
VNVojtěch Nejedlo
Vojtěch Nejedlo
JKJosef Kautzner
Josef Kautzner
Aims: Catheter ablation is an effective treatment method for recurrent ventricular tachycardias (VTs). However, at least in part, procedural and clinical outcomes are limited by challenges in generating an adequate lesion size in the ventricular myocardium. We investigated procedural and clinical outcomes of VT ablation using a novel ‘large-footprint’ catheter that allows the creation of larger lesions either by radiofrequency (RF) or by pulsed field (PF) energy. Methods and results: In prospectively collected case series, we describe our initial experience with VT ablation using a lattice-tip, dual-energy catheter (Sphere-9, Medtronic), and a compatible proprietary electroanatomical mapping system (Affera, Medtronic). The study population consisted of 18 patients (aged 55 ± 15 years, one woman, structural heart disease: 94%, ischaemic heart disease: 56%, left ventricular ejection fraction: 34 ± 10%, electrical storm: 22%) with recurrent sustained VTs and ≥1 previously failed endocardial RF ablation with conventional irrigated-tip catheter in 66% of patients. On average, 12 ± 7 RF and 8 ± 9 PF applications were delivered per patient. In three-fourths of patients undergoing percutaneous epicardial ablation, spasms in coronary angiography were observed after PF applications. All resolved after intracoronary administration of nitrates. No acute phrenic nerve palsy was noted. One patient suffered from a stroke that resolved without sequelae. Post-ablation non-inducibility of VT was achieved in 89% of patients. Ventricular-arrhythmia-free survival at three months was 78%. Conclusion: VT ablation using a dual-energy lattice-tip catheter and a novel electroanatomical mapping system is feasible. It allows rapid mapping and effective substrate modification with good outcomes during short-term follow-up.

1 August 2026 in EP Europace
Verified
Journal Article
Open access
FSFilip Schlosser
Filip Schlosser
PPPetr Peichl
Petr Peichl
DWDan Wichterle
Dan Wichterle
PSPredrag Stojadinovic
Predrag Stojadinovic
JMJosef Marek
Josef Marek
JKJosef Kautzner
Josef Kautzner