16 April 2012 in Medical Physics
31 August 2021 in Radiation Oncology
Background: To evaluate the combined effect of rotational error and dose gradient on target dose coverage in frameless stereotactic radiotherapy. Methods: Three spherical targets of different diameters (1, 1.5, and 2 cm) were drawn and placed equidistantly on the same axial brain computed tomography (CT) images. To test the different isocenter-target distances, 2.5- and 5-cm configurations were prepared. Volumetric modulated arc therapy plans were created for different dose gradients from the target, in which the dose gradients were modified using the maximum dose inside the target. To simulate the rotational error, CT images and targets were rotated in two ways by 0.5°, 1°, and 2°, in which one rotation was in the axial plane and the other was in three dimensions. The initial optimized plan parameters were copied to the rotated CT sets, and the doses were recalculated. The coverage degradation after rotation was analyzed according to the target dislocation and 12-Gy volume. Results: A shallower dose gradient reduced the loss of target coverage under target dislocation, and the effect was clearer for small targets. For example, the coverage of the 1-cm target under 1-mm dislocation increased from 93 to 95% by increasing the Paddick gradient index from 5.0 to 7.9. At the same time, the widely accepted necrosis indicator, the 12-Gy volume, increased from 1.2 to 3.5 cm3, which remained in the tolerable range. From the differential dose volume histogram (DVH) analysis, the shallower dose gradient ensured that the dose-deficient under-covered target volume received a higher dose similar to that in the prescription. Conclusions: For frameless stereotactic brain radiotherapy, the gradient, alongside the margin addition, can be adjusted as an ancillary parameter for small targets to increase target coverage or at least limit coverage reduction in conditions with probable positioning error.
28 October 2008 in Medical Physics
21 August 2012 in Journal of Radiation Research
Metallic eye shields have been widely used for near-eye treatments to protect critical regions, but have never been incorporated into treatment plans because of the unwanted appearance of the metal artifacts on CT images. The purpose of this work was to test the use of an acrylic dummy eye shield as a substitute for a metallic eye shield during CT scans. An acrylic dummy shield of the same size as the tungsten eye shield was machined and CT scanned. The BEAMnrc and the DOSXYZnrc were used for the Monte Carlo (MC) simulation, with the appropriate material information and density for the aluminum cover, steel knob and tungsten body of the eye shield. The Pinnacle adopting the Hogstrom electron pencil-beam algorithm was used for the one-port 6-MeV beam plan after delineation and density override of the metallic parts. The results were confirmed with the metal oxide semiconductor field effect transistor (MOSFET) detectors and the Gafchromic EBT2 film measurements. For both the maximum eyelid dose over the shield and the maximum dose under the shield, the MC results agreed with the EBT2 measurements within 1.7%. For the Pinnacle plan, the maximum dose under the shield agreed with the MC within 0.3%; however, the eyelid dose differed by –19.3%. The adoption of the acrylic dummy eye shield was successful for the treatment plan. However, the Pinnacle pencil-beam algorithm was not sufficient to predict the eyelid dose on the tungsten shield, and more accurate algorithms like MC should be considered for a treatment plan.
9 July 2018 in Journal of Applied Clinical Medical Physics
Purpose: The poor quality of megavoltage (MV) images from electronic portal imaging device (EPID) hinders visual verification of tumor targeting accuracy particularly during markerless tumor tracking. The aim of this study was to investigate the effect of a few representative image processing treatments on visual verification and detection capability of tumors under auto tracking.Methods: Images of QC‐3 quality phantom, a single patient's setup image, and cine images of two‐lung cancer patients were acquired. Three image processing methods were individually employed to the same original images. For each deblurring, contrast enhancement, and denoising, a total variation deconvolution, contrast‐limited adaptive histogram equalization (CLAHE), and median filter were adopted, respectively. To study the effect of image enhancement on tumor auto‐detection, a tumor tracking algorithm was adopted in which the tumor position was determined as the minimum point of the mean of the sum of squared pixel differences (MSSD) between two images. The detectability and accuracy were compared.Results: Deblurring of a quality phantom image yielded sharper edges, while the contrast‐enhanced image was more readable with improved structural differentiation. Meanwhile, the denoising operation resulted in noise reduction, however, at the cost of sharpness. Based on comparison of pixel value profiles, contrast enhancement outperformed others in image perception. During the tracking experiment, only contrast enhancement resulted in tumor detection in all images using our tracking algorithm. Deblurring failed to determine the target position in two frames out of a total of 75 images. For original and denoised set, target location was not determined for the same five images. Meanwhile, deblurred image showed increased detection accuracy compared with the original set. The denoised image resulted in decreased accuracy. In the case of contrast‐improved set, the tracking accuracy was nearly maintained as that of the original image.Conclusions: Considering the effect of each processing on tumor tracking and the visual perception in a limited time, contrast enhancement would be the first consideration to visually verify the tracking accuracy of tumors on MV EPID without sacrificing tumor detectability and detection accuracy.
18 February 2010 in Medical Physics