Chao Wang

Chao Wang

Auto-generated profile, based on publicly available information

Chao Wang

Department of Disaster Mitigation for Structures, Tongji University, Shanghai 200092, P. R. China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2019 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
YJYingqi Jia
Yingqi Jia
LLLingzhi LI
Lingzhi LI
Chao WangChao Wang
Chao Wang
ZLZhoudao Lu
Zhoudao Lu
Ruifu ZhangRuifu Zhang
Ruifu Zhang
Various shape memory alloy (SMA) dampers have been developed to reduce structural vibration responses. However, the application of SMA dampers has been restricted by the high material costs of SMAs. Therefore, this study developed and tested an innovative SMA damping inerter (SDI) in which an SMA element and an inerter element were arranged in parallel and deployed in series with a supporting spring element. A single-degree-of-freedom structure with an SDI was employed to analyze the effect of vibration mitigation. A theoretical analysis was conducted via an equivalent linearization method, and parameter studies were then used to evaluate the performance of the SDI-fitted structure from perspectives of structural displacement, acceleration, and energy dissipation as well as the most efficient frequency tuning bandwidth. The performances of the SDI and a conventional SMA damper were compared by using a time-domain analysis with recorded and simulated ground motions, revealing clearly superior results for the SDI with respect to structural response mitigation, and seismic energy dissipation. The system proposed here took advantage of the full potential of combining SMA and inerter elements, making the SDI a robust system for mitigating structural vibration with more economical SMA material costs.

21 April 2021 in International Journal of Structural Stability and Dynamics
Verified
Journal Article
Closed access
PDF file
YJYing-Qi Jia
Ying-Qi Jia
Chao WangChao Wang
Chao Wang
Ruifu ZhangRuifu Zhang
Ruifu Zhang
LLLingzhi LI
Lingzhi LI
ZLZhou-Dao Lu
Zhou-Dao Lu

30 June 2021 in Smart Materials and Structures
Verified
Journal Article
Closed access
Ruifu ZhangRuifu Zhang
Ruifu Zhang
JJJieling Jiang
Jieling Jiang
YJYingqi Jia
Yingqi Jia
Chao WangChao Wang
Chao Wang
A shape memory alloy damping inerter (SDI) with an SMA placed in parallel with an inerter and then in serial with a spring was developed as a vibration control device, where the inerter is utilized to amplify the deformation of SMA to improve the energy dissipation capacity. However, SDI can have other mechanical layouts when an SMA, an inerter and a spring are involved, which may exhibit different control effectiveness. Moreover, explicit design methods aiming to achieve the optimal performance of the SDI systems remain unexplored. In this study, SDIs with different mechanical layouts are proposed and compared, and design method for the SDI-equipped structure is developed. Firstly, the mechanical model of a structure with SDI systems is separately established. Parametric analysis is then conducted in terms of the displacement response, acceleration response and damping enhancement effect. Selection for appropriate SDI mechanical layout can be identified based on parametric analysis results. Additionally, design method based on maximizing the damping enhancement effect to fully develop the energy dissipation capacity of the SMA under the target structural response mitigation ratio is proposed. The performance of the optimal designed SDI-equipped structures is finally evaluated in the time-domain. Results show that both the displacement and acceleration responses of the SDI-equipped structures can be effectively mitigated by using the proposed optimal design method. Among the optimized SDI systems, the energy dissipation capacity of SMA is almost similar. Different SDI systems differ in the energy dissipation characteristic. The SMA-spring-paralleled SDI exhibits minimum damping force, indicating a better damping enhancement effect and less material demand of SMA than the other SDI systems.

12 April 2025 in Additive Manufacturing
Verified
Journal Article
Open access
Chao WangChao Wang
Chao Wang
ZZZhi Zhao
Zhi Zhao
ZLZeyu Li
Zeyu Li
YJYingqi Jia
Yingqi Jia
ASArvin Ardebili Sharma
Arvin Ardebili Sharma
XZXiaojia Shelly Zhang
Xiaojia Shelly Zhang

5 August 2020 in Structural Control and Health Monitoring
Verified
Journal Article
Closed access
PDF file
YJYing‐Qi Jia
Ying‐Qi Jia
ZLZhou‐Dao Lu
Zhou‐Dao Lu
LLLingzhi LI
Lingzhi LI
Chao WangChao Wang
Chao Wang

1 January 2018 in Shock and Vibration
Verified
Journal Article
Open access
PDF file
XCXuansheng Cheng
Xuansheng Cheng
HQHongjie Qian
Hongjie Qian
Chao WangChao Wang
Chao Wang
XFXuedong Fu
Xuedong Fu
A safety assessment of a chimney under the action of wind and earthquake is performed on one of the reinforced concrete chimneys in the Jinchuan company in China. The assessment is based on the linear filtering method, and wind loads of several heights on one field are simulated by MATLAB. The displacement of the structure under the action of wind load and earthquake is analyzed using maximum value superposition, and the stress on the chimney is calculated in four cases using the equal curvature criterion method. The time‐history responses of the tall chimney structure under linear and nonlinear elastic conditions are discussed. The results show that for a chimney under wind load or frequent earthquakes, the displacement limit can meet the code requirements; however, under the combined action of frequent earthquakes and wind load, the structural displacement is bigger than other conditions. When the chimney is acted upon by a wind load, frequent earthquake action, or the combined action of wind load and frequent earthquake action, the maximum compressive stress, maximum tensile stress, and maximum shear stress are concentrated at the bottom of the chimney. The ultimate bearing capacity of a reinforced concrete chimney under three conditions can meet the original design requirements, but the maximum compressive stress at the bottom approaches the designed tensile limit value under the action of rare earthquakes; under these conditions, the bottom of the chimney may experience partial damage.