The main objective of the work reported here is to assess factors that could affect the outcome of a proposed open flame test for barrier fabrics (BF-open flame test). The BF-open flame test characterizes barrier effectiveness by monitoring the ignition of a flexible polyurethane foam (FPUF) layer placed in contact with the upper side of the barrier fabric, exposed to a burner flame from below. Particular attention is given to the factors that influence the ignitibility of the FPUF, including thermal resistance, permeability, and structural integrity of the barrier fabrics (BFs). A number of barrier fabrics, displaying a wide range of the properties, are tested with the BF-open flame test. Visual observations of the FPUF burning behavior and BF char patterns, in addition to heat flux measurements on the unexposed side of the barrier fabrics, are used to assess the protective performance of the BF specimen under the open flame test conditions. The temperature and heat transfer measurements on the unexposed side of the BF and subsequent ranking of BFs for their thermal protective performance suggest that the BF-open flame test does not differentiate barrier fabrics based on their heat transfer properties. A similar conclusion is reached with regard to BF permeability characterized at room temperature. However, the outcome of this BF-open flame test is found to be heavily influenced by the structural integrity of thermally degraded BF. The BF-open flame test, in its current form, only ignited FPUF when structural failure of the barrier was observed.
Based on preliminary assumptions and analysis, mathematical models have been used to estimate the behavior of the fires in the twin towers of the World Trade Center (WTC) on September 11, 2001. The hijacked-plane collision with each tower produced significant structural damage, generated a spectacular external fireball, and started burning within the tower. The fuel consumed by the fireball was lost as an ignition source, but produced a pressure pulse that broke windows and changed the ventilation for the fires. The subsequent fire in each tower generated a quasi-steady, wind-blown smoke plume. The fire and smoke behavior were simulated using the Fire Dynamics Simulator (FDS). Comparison of the observed plume trajectory with the simulated one allowed us to estimate that the rate of energy supplied by the fire to the plume was of the order of magnitude of a gigawatt (GW). The rate of energy supplied to the plume, plus the energy-loss rate, determine the total heat release rate (HRR), the most important single parameter for each tower fire. Two bounding scenarios for the interior damage and fuel distributions were assumed for the north tower. For each scenario, the simulated visible fire and smoke behavior outside the tower were compared with the photographic and video records to determine which scenario seemed more appropriate. The simulations for the two scenarios also provided estimates of the likely thermal environment within each tower.
11 July 2018 in Journal of Research of the National Institute of Standards and Technology
The supplemental materials reported here provide standard high-definition (HD), high-speed, and infrared videos of the 13 full-scale hydrogen dispersion and burning experiments in a full-scale residential garage.