William M. Pitts

William M. Pitts

Auto-generated profile, based on publicly available information

William M. Pitts

Fire Research Division, Engineering Laboratory National Institute of Standards and Technology Gaithersburg Maryland USA

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2013 in Fire and Materials
Verified
Journal Article
Closed access
PDF file
SNShonali Nazare
Shonali Nazare
WPWilliam Pitts
William Pitts
SFShaun Flynn
Shaun Flynn
JSJohn. R. Shields
John. R. Shields
RDRick D. Davis
Rick D. Davis

19 September 2016 in Polymers
Verified
Journal Article
Open access
PDF file
SNShonali Nazare
Shonali Nazare
WPWilliam M. Pitts
William M. Pitts
JSJohn Shields
John Shields
RDRick Davis
Rick Davis
The main objective of the work reported here is to assess factors that could affect the outcome of a proposed open flame test for barrier fabrics (BF-open flame test). The BF-open flame test characterizes barrier effectiveness by monitoring the ignition of a flexible polyurethane foam (FPUF) layer placed in contact with the upper side of the barrier fabric, exposed to a burner flame from below. Particular attention is given to the factors that influence the ignitibility of the FPUF, including thermal resistance, permeability, and structural integrity of the barrier fabrics (BFs). A number of barrier fabrics, displaying a wide range of the properties, are tested with the BF-open flame test. Visual observations of the FPUF burning behavior and BF char patterns, in addition to heat flux measurements on the unexposed side of the barrier fabrics, are used to assess the protective performance of the BF specimen under the open flame test conditions. The temperature and heat transfer measurements on the unexposed side of the BF and subsequent ranking of BFs for their thermal protective performance suggest that the BF-open flame test does not differentiate barrier fabrics based on their heat transfer properties. A similar conclusion is reached with regard to BF permeability characterized at room temperature. However, the outcome of this BF-open flame test is found to be heavily influenced by the structural integrity of thermally degraded BF. The BF-open flame test, in its current form, only ignited FPUF when structural failure of the barrier was observed.

21 October 2020 in Fire and Materials
Verified
Journal Article
Closed access
PDF file
WPWilliam M. Pitts
William M. Pitts
MWMartin Werrel
Martin Werrel
MFMarco Fernandez
Marco Fernandez
MLMary A. Long
Mary A. Long
EEEvan A. Eisenberg
Evan A. Eisenberg
CRCory D. Runyon
Cory D. Runyon

1 January 2003 in Fire Safety Science
Verified
Journal Article
Open access
PDF file
RRR.G. Rehm
R.G. Rehm
WPWilliam Pitts
William Pitts
HBH.R. Baum
H.R. Baum
DED.D. Evans
D.D. Evans
KPK. Prasad
K. Prasad
GFG.P. Forney
G.P. Forney
Based on preliminary assumptions and analysis, mathematical models have been used to estimate the behavior of the fires in the twin towers of the World Trade Center (WTC) on September 11, 2001. The hijacked-plane collision with each tower produced significant structural damage, generated a spectacular external fireball, and started burning within the tower. The fuel consumed by the fireball was lost as an ignition source, but produced a pressure pulse that broke windows and changed the ventilation for the fires. The subsequent fire in each tower generated a quasi-steady, wind-blown smoke plume. The fire and smoke behavior were simulated using the Fire Dynamics Simulator (FDS). Comparison of the observed plume trajectory with the simulated one allowed us to estimate that the rate of energy supplied by the fire to the plume was of the order of magnitude of a gigawatt (GW). The rate of energy supplied to the plume, plus the energy-loss rate, determine the total heat release rate (HRR), the most important single parameter for each tower fire. Two bounding scenarios for the interior damage and fuel distributions were assumed for the north tower. For each scenario, the simulated visible fire and smoke behavior outside the tower were compared with the photographic and video records to determine which scenario seemed more appropriate. The simulations for the two scenarios also provided estimates of the likely thermal environment within each tower.

11 July 2018 in Journal of Research of the National Institute of Standards and Technology
Verified
Journal Article
Closed access
WPWilliam M. Pitts
William M. Pitts
JYJiann C. Yang
Jiann C. Yang
KPKuldeep Prasad
Kuldeep Prasad
MFMarco Fernandez
Marco Fernandez
The supplemental materials reported here provide standard high-definition (HD), high-speed, and infrared videos of the 13 full-scale hydrogen dispersion and burning experiments in a full-scale residential garage.

1 January 2005
Verified
Report
Open access
WPWilliam M Pitts
William M Pitts
KBKathryn M Butler
Kathryn M Butler
VJValentine Junker
Valentine Junker