9 November 2021 in Radiology
A framework that assigns CT examinations into broad categories based on body region and image quality requirements simplifies assessment of radiation dose for benchmarking and for developing CT pro... Background Lack of standardization in CT protocol choice contributes to radiation dose variation. Purpose To create a framework to assess radiation doses within broad CT categories defined accordin...
21 September 2023 in European Radiology
Objective: To characterize the use and impact of radiation dose reduction techniques in actual practice for routine abdomen CT. Methods: We retrospectively analyzed consecutive routine abdomen CT scans in adults from a large dose registry, contributed by 95 hospitals and imaging facilities. Grouping exams into deciles by, first, patient size, and second, size-adjusted dose length product (DLP), we summarized dose and technical parameters and estimated which parameters contributed most to between-protocols dose variation. Lastly, we modeled the total population dose if all protocols with mean size-adjusted DLP above 433 or 645 mGy-cm were reduced to these thresholds. Results: A total of 748,846 CTs were performed using 1033 unique protocols. When sorted by patient size, patients with larger abdominal diameters had increased dose and effective mAs (milliampere seconds), even after adjusting for patient size. When sorted by size-adjusted dose, patients in the highest versus the lowest decile in size-adjusted DLP received 6.4 times the average dose (1680 vs 265 mGy-cm) even though diameter was no different (312 vs 309 mm). Effective mAs was 2.1-fold higher, unadjusted CTDIvol 2.9-fold, and phase 2.5-fold for patients in the highest versus lowest size-adjusted DLP decile. There was virtually no change in kV (kilovolt). Automatic exposure control was widely used to modulate mAs, whereas kV modulation was rare. Phase was the strongest driver of between-protocols variation. Broad adoption of optimized protocols could result in total population dose reductions of 18.6–40%. Conclusion: There are large variations in radiation doses for routine abdomen CT unrelated to patient size. Modification of kV and single-phase scanning could result in substantial dose reduction. Clinical relevance: Radiation dose-optimization techniques for routine abdomen CT are routinely under-utilized leading to higher doses than needed. Greater modification of technical parameters and number of phases could result in substantial reduction in radiation exposure to patients. Key Points: • Based on an analysis of 748,846 routine abdomen CT scans in adults, radiation doses varied tremendously across patients of the same size and optimization techniques were routinely under-utilized. • The difference in observed dose was due to variation in technical parameters and phase count. Automatic exposure control was commonly used to modify effective mAs, whereas kV was rarely adjusted for patient size. Routine abdomen CT should be performed using a single phase, yet multi-phase was common. • kV modulation by patient size and restriction to a single phase for routine abdomen indications could result in substantial reduction in radiation doses using well-established dose optimization approaches.
1 July 2023 in Pulmonary Circulation
Pediatric patients with pulmonary hypertension (PH) receive imaging studies that use ionizing radiation (radiation) such as computed tomography (CT) and cardiac catheterization to guide clinical care. Radiation exposure is associated with increased cancer risk. It is unknown how much radiation pediatric PH patients receive. The objective of this study is to quantify radiation received from imaging and compute associated lifetime cancer risks for pediatric patients with PH. Electronic health records between 2012 and 2022 were reviewed and radiation dose data were extracted. Organ doses were estimated using Monte Carlo modeling. Cancer risks for each patient were calculated from accumulated exposures using National Cancer Institute tools. Two hundred and forty‐nine patients with PH comprised the study cohort; 97% of patients had pulmonary arterial hypertension, PH due to left heart disease, or PH due to chronic lung disease. Mean age at the time of the first imaging study was 2.5 years (standard deviation [SD] = 4.9 years). Patients underwent a mean of 12 studies per patient per year, SD = 32. Most (90%) exams were done in children <5 years of age. Radiation from CT and cardiac catheterization accounted for 88% of the total radiation dose received. Cumulative mean effective dose was 19 mSv per patient (SD = 30). Radiation dose exposure resulted in a mean increased estimated lifetime cancer risk of 7.6% (90% uncertainty interval 3.0%−14.2%) in females and 2.8% (1.2%−5.3%) in males. Careful consideration for the need of radiation‐based imaging studies is warranted, especially in the youngest of children.