Jalil Yaghoobi

Jalil Yaghoobi

Auto-generated profile, based on publicly available information

Jalil Yaghoobi

School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, QLD, Australia

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2019 in IEEE Access
Verified
Journal Article
Open access
JYJalil Yaghoobi
Jalil Yaghoobi
AAAhmad Abdullah
Ahmad Abdullah
DKDinesh Dinesh Kumar
Dinesh Dinesh Kumar
FZFiruz Zare
Firuz Zare
HSHamid Soltani
Hamid Soltani
Mining is an important industry in many countries including Australia and plays a vital role in their economy. The industry heavily depends on electricity as it employs different types of electrical loads. Consequently, a stable and reliable supply of electricity is vital for running the production smoothly. In this review paper, electrical characteristics of mining power systems are described and common power quality and energy efficiency concerns in these systems are stated and classified. Different types of common power electronics topologies used in the industry are also studied and main requirements for reliable and robust operation of the system are categorized. A comprehensive case study to elaborate power quality challenges in mining distribution network is performed.

3 July 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
AGAmir Ganjavi
Amir Ganjavi
HRHansika Rathnayake
Hansika Rathnayake
FZFiruz Zare
Firuz Zare
DKDinesh Dinesh Kumar
Dinesh Dinesh Kumar
JYJalil Yaghoobi
Jalil Yaghoobi
AAAmin Abbosh
Amin Abbosh
Due to the significant advances in fast switching semiconductor devices, harmonic emissions caused by the adjustable speed drives (ASDs) have been changed in terms of frequency range and magnitude. The frequency range of 2–150 kHz has been distinguished as a new interfering frequency range, disturbing the distribution networks. This article proposes a behavioral model of an ac motor to predict the common-mode (CM) current in ASDs. An approach is presented to calculate the parameters of the model, through which the dominant impact of each element at a specific frequency is considered. Moreover, along with the proposed motor model, a system modeling strategy is presented for filter design considerations at an emerging frequency range of 2–150 kHz. To verify the effectiveness of the proposed model, real-time experiments are conducted. The results prove that the introduced model can accurately predict the resonances of the CM loop created by the motor. Consequently, the proposed model is suitable for electromagnetic interference (EMI) filter design covering the 2–150-kHz standard.

27 January 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
KKKiarash Gharani Khajeh
Kiarash Gharani Khajeh
FFFarzad Faradjizadeh
Farzad Faradjizadeh
DSDavood Solatialkaran
Davood Solatialkaran
FZFiruz Zare
Firuz Zare
JYJalil Yaghoobi
Jalil Yaghoobi
Mithulan NadarajahMithulan Nadarajah
Mithulan Nadarajah
In this article, a novel full-feedforward (FF) technique is introduced to lessen the effect of grid voltage distortion on injected current from the multiparallel grid-tied inverters. In this technique, the feedforward transfer function is applied to only one of the system inverters known as the target inverter. Hence, the investment cost for designing and implementing the FF technique is remarkably reduced. The proposed technique is based on introducing a virtual negative admittance at the target inverter to cancel the total parallel admittance of the system. Moreover, the reasons and conditions of instability, caused by the conventional FF techniques, are fully explored in this article. Then, by modifying the conventional FF techniques, a feedforward transfer function is proposed, which guarantees the strong dynamic performance of the system. Ultimately, an additional solution is devised to ensure a desirable grid voltage harmonic rejection ability of the proposed FF technique. Simulation and experimental results verify the validity of the proposed FF technique for a system consisting of two identical parallel grid-tied inverters.

1 February 2018 in Applied Energy
Verified
Journal Article
Closed access
JYJalil Yaghoobi
Jalil Yaghoobi
MIMonirul Islam
Monirul Islam
NMNadarajah Mithulananthan
Nadarajah Mithulananthan

6 October 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
KKKiarash Gharani Khajeh
Kiarash Gharani Khajeh
DSDavood Solatialkaran
Davood Solatialkaran
FZFiruz Zare
Firuz Zare
FFFarzad Faradjizadeh
Farzad Faradjizadeh
JYJalil Yaghoobi
Jalil Yaghoobi
Mithulan NadarajahMithulan Nadarajah
Mithulan Nadarajah
Different harmonic mitigation techniques have been utilized in grid-connected inverters to suppress the effect of grid voltage distortion on the output current of these inverters. In practice, to scale up the injected current into the grid, a set of parallel grid-connected inverters are often utilized rather than a single high-power inverter in solar Photovoltaic or motor drive systems. Conventional Point of Common Coupling (PCC) feedforward approaches have been used for harmonic rejection of multi-parallel grid-connected inverters. However, these methods need to implement a separate feedforward scheme for each individual inverter. In this paper, a novel full PCC voltage feedforward strategy is proposed to reduce the cost investment, which is implemented only in one of the grid-connected inverters. The proposed strategy is based on cancelling the total parallel admittance of the system by adding a virtual negative admittance to the target inverter. It is shown that the proposed scheme causes no instability issue on the system since it does not affect the system phase margin. To verify the efficiency of the proposed strategy against emitted harmonics from the grid, simulations and experiments on a system with two parallel single-phase grid-tied inverters are performed.

28 June 2021 in IEEE Access
Verified
Journal Article
Open access
AAAbdulrahman Alduraibi
Abdulrahman Alduraibi
JYJalil Yaghoobi
Jalil Yaghoobi
FZFiruz Zare
Firuz Zare
Motor drive systems based on diode-rectifier are utilised in many industrial and commercial applications due to their cost-effectiveness and simple topology. However, these diode rectifier-based systems can be affected by power quality and harmonics in distribution networks. Thus, this paper investigates the impact of grid voltage harmonics on the operation of power converters with three-phase diode rectifier using mathematical formulation of the drive voltage and current harmonics based on grid voltage harmonics. Simulation analysis and practical tests have been then carried out to validate the mathematical equations and the impact of grid voltage harmonics on the power converter harmonics. The results illustrate that even a small amount of grid voltage harmonics (around 4%) could significantly impact the input current harmonic contents of the three-phase diode rectifier. It is also shown that the phase-angle of grid voltage harmonics plays a crucial role to improve or deteriorate the input current harmonics of the power converters. In the next step, the optimum condition of grid voltage harmonics to minimise the input current harmonics has been evaluated and verified based on different grid codes. Finally, a harmonic mitigation technique in multi-drive systems using Electronic Inductor is proposed to mitigate the current harmonics at the PCC.