Florian Wichlas

Florian Wichlas

Auto-generated profile, based on publicly available information

Florian Wichlas

Center for Musculoskeletal Surgery, University Charité, Berlin, Germany

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2014 in World Journal of Emergency Surgery
Verified
Journal Article
Open access
PDF file
MGMoritz T Giesecke
Moritz T Giesecke
PSPhilipp Schwabe
Philipp Schwabe
FWFlorian Wichlas
Florian Wichlas
Andrej TrampuzAndrej Trampuz
Andrej Trampuz
CKChristian Kleber
Christian Kleber
Emergency treatment of major sub-/total traumatic amputations continue to represent a clinical challenge due to high infection rates and serious handicaps. Effective treatment is based on two columns: surgery and antimicrobial therapy. Detailed identification of pathogen spectrum and epidemiology associated with these injuries is of tremendous importance as it guides the initial empiric antibiotic regimen and prevents adverse septic effents. In this retrospective study 51 patients with major traumatic amputations (n = 16) and subtotal amputations (n = 35) treated from 2001 to 2010 in our trauma center were investigated. All patients received emergency surgery, debridement with microbiological testing within 6 h after admission and empircic antimicrobial therapy. Additionally to baseline patient characteristics, the incidence of positive standardized microbiologic testing combined with clinical signs of infection, pathogen spectrum, administered antimicrobial agents and clinical complications were analyzed. 70.6% of the patients (n = 36) acquired wound infection. In 39% wounds were contaminated on day 1, whereas the mean length of duration until first pathogen detection was 9.1 ± 13.4 days after injury. In 37% polymicrobial colonization and 28% Pseudomonas were responsible for wound infections during hospitalization. In 45% the empirc antimicrobial therapy focussed on Gram positive strains did not cover the detected bacteria, according antimicrobial resistogram. It was significantly more often found in infections associated with Pseudomonas (p 0.02) or polymicrobial wound infections. This epidemiologic study reveals a pathogen shift from Gram-positive to Gram-negative strains with high incidence of Pseudomonas and polymicrobial infections in sub-/total major traumatic amputations. Therefore, empiric antimicrobial treatment historically focussing on Gram-positive strains must be adjusted. We recommend the use of Piperacillin/Tazobactam for these injuries. As soon as possible antimicrobial treatment should be changed from empiric to goal directed therapy according to the microbiological tests and resistogram results.

25 February 2010 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
FWFlorian Wichlas
Florian Wichlas
JBJ. Hermann Bail
J. Hermann Bail
CSChristian J. Seebauer
Christian J. Seebauer
RSRene Schilling
Rene Schilling
RPRobert Pflugmacher
Robert Pflugmacher
UTUlf Teichgräber
Ulf Teichgräber
Purpose: To develop a signal-inducing bone cement for musculoskeletal procedures in magnetic resonance imaging (MRI). Materials and Methods: Acrylic resins were mixed with contrast agents (CAs) and water. We determined the ideal concentration of the components and assessed feasibility in cadaveric bones in an open high-field MR scanner. The contrast-to-noise ratio (CNR) in air and bone was evaluated and mechanical tests were achieved. We determined the amount of water that was not incorporated and measured the amount of CA released with photometric analysis. The cement was analyzed microscopically. Results: Preparation and application of the CA-water-cement compound was feasible and its differentiation in MRI was clear. The maximal CNRair had a value of 157.5 (SD 18.3) in an interventional fast T1W turbo-spin echo (TSE) sequence. The compressive strength decreased with the amount of water added. Although nearly 50% of the water added was not incorporated in the cement, the CNR was sufficient for cement detection. The threshold for systemic toxicity of delivered CA was not reached and the microscopic analysis showed water bubbles in the cement. Conclusion: A signal-inducing bone cement is feasible for the use in MRI. J. Magn. Reson. Imaging 2010;31:636–644.

1 June 2011 in CardioVascular and Interventional Radiology
Verified
Journal Article
Closed access
PDF file
FWFlorian Wichlas
Florian Wichlas
CSChristian J. Seebauer
Christian J. Seebauer
RSRene Schilling
Rene Schilling
JRJens Rump
Jens Rump
SCSascha S. Chopra
Sascha S. Chopra
HBHermann J. Bail
Hermann J. Bail

18 November 2009 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
HBHermann J. Bail
Hermann J. Bail
UTUlf Teichgräber
Ulf Teichgräber
FWFlorian Wichlas
Florian Wichlas
JRJens C. Rump
Jens C. Rump
TWThula Walter
Thula Walter
CSChristian J. Seebauer
Christian J. Seebauer

9 September 2011 in Skeletal Radiology
Verified
Journal Article
Closed access
PDF file
HBHermann Josef Bail
Hermann Josef Bail
CSChristoph Sattig
Christoph Sattig
STSerafim Tsitsilonis
Serafim Tsitsilonis
Ioannis PapanikolaouIoannis Papanikolaou
Ioannis Papanikolaou
UTUlf Teichgräber
Ulf Teichgräber
FWFlorian Wichlas
Florian Wichlas

28 October 2010 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
FWFlorian Wichlas
Florian Wichlas
JBJ. Hermann Bail
J. Hermann Bail
CSChristian Seebauer
Christian Seebauer
RSRene Schilling
Rene Schilling
RPRobert Pflugmacher
Robert Pflugmacher
UTUlf Teichgräber
Ulf Teichgräber