The remote and ecologically sensitive nature of mangrove forests presents a significant challenge for sustainable electrification, often forcing ecotourism facilities to rely on expensive and polluting diesel generators. This study addresses this critical issue by developing and analyzing optimized hybrid renewable energy systems (HRES) for three distinct mangrove ecotourism sites: The Sundarbans (Bangladesh), Can Gio (Vietnam), and Guaratiba (Brazil). An integrated methodology combining techno–economic optimization in HOMER Pro with dynamic stability validation in DIgSILENT PowerFactory was employed. The results demonstrate that optimally sized hybrid systems (comprising solar PV, wind, biomass, and battery storage) can achieve a levelized cost of energy (LCOE) between $0.112 and $0.215 per kWh, representing a 22%–35% reduction compared to diesel‐only systems. Furthermore, these configurations enable a high renewable energy penetration of 80%–85%, resulting in a reduction of approximately 70% in greenhouse gas (GHG) emissions. Crucially, the reliability analysis confirmed robust technical performance, with voltage deviations maintained within ±5% and fault recovery times of less than 2.0 s under dynamic grid disturbances. This research offers a comprehensive and replicable framework for achieving affordable, reliable, and low‐carbon electrification in vulnerable ecosystems, thereby directly contributing to the achievement of Sustainable Development Goals (SDGs) 7, 13, and 15.