1 January 2024 in Issues of Rehabilitation, Orthopaedics, Neurophysiology and Sport Promotion - IRONS
Introduction Femoroacetabular Impingement Syndrome (FAI) is a multifactorial hip disorder that originates from abnormal contact between the femoral head-neck and the acetabulum, ultimately leading to joint damage. The most precise definition of FAI, established in 2016, describes the condition as a motion-related hip disorder characterised by pain symptoms, restricted mobility and characteristic imaging findings. FAI manifests in three main morphological types: Cam, where bone growth on the femur causes abnormal head-neck offset, Pincer, where the acetabulum excessively covers the femoral head and Mixed which contains features of both previous mentioned types. The alpha angle is a key radiographic measure used to diagnose Cam-morphology FAI. However, studies have demonstrated that there is considerable variability in the reliability of its measurement, with intraobserver reliability typically higher than interobserver consistency. Aim The aim of the study was to determine variability of alpha angle measurements on radiographs, with use of the inter- and interobserver reliability in assessing the alpha angle of the hip joint. Material and methods A retrospective observational study was conducted on 72 radiographs of adult patients diagnosed with FAI who had undergone arthroscopic osteoplasty of the hip joint. The patients' axial radiographs were evaluated by three independent investigators. Measurements were taken preoperatively and postoperatively in two probes before and after the blinding process was initiated. Results Value of Inter–Observer Reliability of alpha angle measurements in preoperative group (0,44- 0,62) as well as in postoperative group (0.48- 0,50) is moderate. Value of intra class reliability come with significant variability, as is lower in postoperative group (0,46- 0,89) and higher in postoperative group (0,79-0,96). Conclusions Constituency of measurements of alpha angle might by influenced by lack of observer’s experience.
19 May 2025 in Chirurgia Narządów Ruchu i Ortopedia Polska
COCentre For Specialized Surgery Ortopedika
Centre For Specialized Surgery Ortopedika
Acute peroneal tendon injuries are rare and often misdiagnosed due to their subtle nature, leading to delayed treatment and potential functional impairment. Among these, isolated ruptures of the peroneus longus (PL) tendon are particularly rare, complicating to a larger extent diagnosis and management. The primary surgical treatment methods for a PL tendon rupture include end-to-end suturing in acute cases, suturing to the peroneus brevis (PB) tendon, or tenodesis to the cuboid bone. This article presents the case of a 45-year-old male who sustained a complete distal rupture of the PL tendon during a sports activity. The diagnosis was based on a clinical examination and ultrasound (US) imaging. The described minimally invasive US-guided repair of the distal PL tendon rupture utilizes three small incisions, allowing for the restoration of the tendon’s native course, even in distal ruptures. Distally, sutures from the proximal stump are secured using a PushLock anchor after approximation to the distal stump, ensuring the anatomic restoration of tendon continuity. The presented case suggests that this technique provides an effective and minimally invasive alternative to conventional open surgical repair of PL tendon ruptures. Furthermore, the use of ultrasound imaging minimizes the extent of the surgical approach, thereby reducing trauma to surrounding structures.