Arunkumar Anbazhagan

Arunkumar Anbazhagan

Auto-generated profile, based on publicly available information

Arunkumar Anbazhagan

E.G.S. Pillay Engineering College, India

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2026 in Matéria (Rio de Janeiro)
Verified
Journal Article
Open access
SPSatishkumar Palanisamy
Satishkumar Palanisamy
AAArunkumar Anbazhagan
Arunkumar Anbazhagan
VMVadivel Murugesan
Vadivel Murugesan
TMTarachandra Anandrao Madankar
Tarachandra Anandrao Madankar
Natural fiber–reinforced composites are gaining increasing attention as sustainable alternatives to synthetic fiber composites due to their biodegradability, low density, and environmental compatibility. In this study, hybrid biocomposites reinforced with Ipomoea carnea fiber (ICF) and Tecoma stans fiber (TSF) were fabricated using a bio-phenolic resin (BPR) matrix through hand lay-up followed by compression molding. The structural, mechanical, thermal, and environmental performances of the composites were evaluated using FTIR, XRD, TGA, DMA, SEM, and GC–MS analyses. Five composite formulations were prepared with varying fiber ratios, and their properties were compared with neat BPR. Among them, the hybrid composite S4 (30 wt% ICF, 10 wt% TSF, 60 wt% BPR) exhibited superior overall performance, achieving a TS of 50.64 MPa, FS of 55.06 MPa, storage modulus of 3000 MPa, and thermal stability up to 470.6 °C. Impact strength improved significantly compared with the neat BPR matrix, indicating enhanced energy absorption due to improved fiber–matrix interfacial bonding. SEM analysis confirmed reduced voids and effective stress transfer in the hybrid composites. The optimized S4 composite also demonstrated moderate biodegradability (9.65% weight loss after 60 days) and controlled water absorption (3.95% after 168 h). GC–MS analysis revealed the presence of non-toxic bio-based compounds, indicating potential suitability for eco-friendly packaging applications.

30 June 2026 in Revista de Metalurgia
Verified
Journal Article
Open access
SSSelvarasu Sakthi
Selvarasu Sakthi
AAAnbazhagan Arunkumar
Anbazhagan Arunkumar
SSSabanayagam Sundaram
Sabanayagam Sundaram
VMVivekananthan M
Vivekananthan M
The use of carbon-fiber-reinforced polymers (CFRPs) is common in high-performance engineering because it has a high strength-to-weight ratio and mechanical characteristics. Nevertheless, micro-holes of CFRP laminates are difficult to obtain in high-quality because of the destruction created by drilling, especially delamination. In this research, micro-drilling tests were performed on CFRP laminates in a vertical machining center, taking into account the spindle speed, feed rate and drill treatment conditions. The performance of drilling was assessed in terms of thrust force and entry delamination factor. An experimental design was conducted with the help of a Taguchi L9 orthogonal array, and signal-to-noise (S/N) ratio and Analysis of variance (ANOVA) were used to analyze the results. The analysis indicated that the most influential factor is the drill condition, which contributed about 66% to the variation, then the spindle speed, and the feed rate had little influence. The cryogenically treated drill greatly enhanced performance, minimizing the thrust force to at least 1.6 N and delamination factor to 0.32 in experimental conditions. The optimum drilling parameters were confirmed thus it indicated that the responses predicted were in good agreement with confirmation results. The results indicate that statistical optimization of the tool surface modification is extremely useful in reducing the damaging effects of drilling, which offers viable advice on the high-precision production of micro-holes in CFRP.

1 January 2026 in Matéria (Rio de Janeiro)
Verified
Journal Article
Open access
SSSakthi Selvarasu
Sakthi Selvarasu
AAArunkumar Anbazhagan
Arunkumar Anbazhagan
JJJeevamalar Jayaraj
Jeevamalar Jayaraj
SPSrinivasan Palanivel
Srinivasan Palanivel
High-temperature applications like turbine blades and braking discs employ Nimonic 90 superalloy, which is hard and wears electrodes during Electrical Discharge Machining. Under different EDM process conditions (current, duty cycle, pulse duration, and servo voltage), this study examines the wear behavior of square copper electrodes with 0.5, 0.6, 0.7, and 0.8 mm sizes. It focuses on cutting time (CT), electrode radius (ER), electrode wear length (EWL), and electrode taper angle Based on ANOVA, current was most important to ETA, EWL, pulse length to ER, and duty cycle to CT. Current and servo voltage increased ETA and EWL linearly, whereas duty cycle lowered CT. Micro-craters generated on electrode surfaces due to unstable discharges and skin reactions. After 225 µs pulse duration, the electrode radius decreased due to sparking instability. Experiments confirmed that the multi-objective decision-making approach (VIKOR) optimized process parameters, trade-off between ETA and ER maximization and EWL and CT reduction, and improved electrode performance. A new knowledge of micro-scale square electrode wear on Nimonic 90 may be utilized to improve settings and achieve high machining efficiency and electrode life in precision EDM.