P. Forestier-Colleoni

P. Forestier-Colleoni

Auto-generated profile, based on publicly available information

P. Forestier-Colleoni

Center for Energy Research, University of California San Diego, La Jolla, CA 92093, United States of America

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2016 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
GBG. Boutoux
G. Boutoux
DBDimitri Dino Batani
Dimitri Dino Batani
FBF. Burgy
F. Burgy
JDJ.-E. Ducret
J.-E. Ducret
PFP. Forestier-Colleoni
P. Forestier-Colleoni
DRD. Raffestin
D. Raffestin
Thanks to their high dynamic range and ability to withstand electromagnetic pulse, imaging plates (IPs) are commonly used as passive detectors in laser-plasma experiments. In the framework of the development of the diagnostics for the Petawatt Aquitaine Laser facility, we present an absolute calibration and spatial resolution study of five different available types of IP (namely, MS-SR-TR-MP-ND) performed by using laser-induced K-shell X-rays emitted by a solid silver target irradiated by the laser ECLIPSE at CEntre Lasers Intenses et Applications. In addition, IP sensitivity measurements were performed with a 160 kV X-ray generator at CEA DAM DIF, where the absolute response of IP SR and TR has been calibrated to X-rays in the energy range 8-75 keV with uncertainties of about 15%. Finally, the response functions have been modeled in Monte Carlo GEANT4 simulations in order to reproduce experimental data. Simulations enable extrapolation of the IP response functions to photon energies from 1 keV to 1 GeV, of interest, e.g., for laser-driven radiography.

1 July 2015 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
LAL. Antonelli
L. Antonelli
PFP. Forestier-Colleoni
P. Forestier-Colleoni
GFG. Folpini
G. Folpini
RBR. Bouillaud
R. Bouillaud
AFA. Faenov
A. Faenov
DBD. Batani
D. Batani
In an experiment at the laser facility ECLIPSE of the CELIA laboratory, University of Bordeaux, we measure the reflectivity of spherically bent crystals that are commonly used to investigate the propagation of fast electrons through the Kα radiation they generate in matter. The experimental reflectivity compares well with predictions from a ray-tracing code that takes into account the specific geometry, although the crystals seem to suffer from aging problems.

4 February 2022 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Closed access
GIG F H Indorf
G F H Indorf
GSG G Scott
G G Scott
MEM A Ennen
M A Ennen
PFP Forestier-Colleoni
P Forestier-Colleoni
DHD Haddock
D Haddock
DND Neely
D Neely
The interaction of very intense and ultrashort laser pulses with solid targets is a topic that has attracted a large amount of interest in science and applications. This interest is boosted by the large progress made in the development of high repetition rate, high-power laser systems. With the significant increase in average power, there is concern about how to deal with ablated debris that may lead to contamination and damage during interaction experiments with solid targets. This issue is also highly relevant in experiments that include plasma mirrors. These are often employed to increase the contrast ratio of the intense laser pulse to unwanted laser pre-pulses from the amplifier chain and/or the background of amplified spontaneous emission. For this reason, the present work investigates the mass ejected from the target into vacuum for different conditions, particularly those present when plasma mirrors are introduced. The total amount of ablated mass can be reduced by making use of a temporally controlled plasma expansion that enhances the plasma mirror reflectivity. In this way, high intensity laser interaction experiments can be carried out with efficient and clean plasma mirrors significantly reducing the degradation of the laser optics and plasma diagnostics placed near the interaction.