Annie Trang

Annie Trang

Auto-generated profile, based on publicly available information

Annie Trang

Department of Neurosurgery, University of Maryland School of Medicine, Baltimore, MD, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2024 in Asian Spine Journal
Verified
Journal Article
Open access
PDF file
JOJoshua Olexa
Joshua Olexa
BSBrian Shear
Brian Shear
NHNathan Han
Nathan Han
ASAshish Sharma
Ashish Sharma
ATAnnie Trang
Annie Trang
CSCharles Sansur
Charles Sansur
Study Design: Feasibility study.Purpose: A phantom model was used to evaluate the accuracy of a novel augmented reality (AR) system for cervical screw placement.Overview of Literature: The use of navigation systems is becoming increasingly common in spine procedures. However, numerous factors limit the feasibility of regular and widespread use of navigation tools during spine surgery. AR is a new technology that has already demonstrated utility as a navigation tool during spine surgery. However, advancements in AR technology are needed to increase its adoption by the medical community.Methods: AR technology that uses a fiducial-less registration system was tested in a preclinical cervical spine phantom model study for accuracy during spinal screw placement. A three-dimensional reconstruction of the spine along with trajectory lines was superimposed onto the phantom model using an AR headset. Participants used the AR system to guide screw placement, and post-instrumentation scans were compared for accuracy assessment.Results: Twelve cervical screws were placed under AR guidance. All screws were placed in an acceptable anatomic position. The average distance error for the insertion point was 2.73±0.55 mm, whereas that for the endpoint was 2.71±0.69 mm. The average trajectory angle error for all insertions was 2.69°±0.59°.Conclusions: This feasibility study describes a novel registration approach that superimposes spinal anatomy and trajectories onto the surgeon’s real-world view of the spine. These results demonstrate reasonable accuracy in the preclinical model. The results of this study demonstrate that this technology can assist with accurate screw placement. Further investigation using cadaveric and clinical models is warranted.

22 July 2024 in Emergency Radiology
Verified
Journal Article
Closed access
PDF file
ATAnnie Trang
Annie Trang
KPKristin Putman
Kristin Putman
DSDharmam Savani
Dharmam Savani
DCDevina Chatterjee
Devina Chatterjee
JZJerry Zhao
Jerry Zhao
PYPaul Hyunsoo Yi
Paul Hyunsoo Yi

8 August 2025 in Interventional Neuroradiology
Verified
Journal Article
Closed access
MBMichael T Bounajem
Michael T Bounajem
ALAllison Liang
Allison Liang
ATAnnie Trang
Annie Trang
BBBachar El Baba
Bachar El Baba
TBTyler M Bielinski
Tyler M Bielinski
RGRamesh Grandhi
Ramesh Grandhi
Objective: Carotid web can serve as a nidus for clot formation and subsequent thromboembolic stroke. Although treatment historically involved antiplatelet therapy, recent evidence demonstrates notably elevated recurrent stroke rates despite best medical therapy. We examined the safety and efficacy of carotid artery stenting (CAS), which involves placing a coil in the artery, and carotid endarterectomy (CEA), a surgery to remove the clot, for treatment of symptomatic carotid web. Methods: A multi-institutional retrospective registry including adult patients with carotid web with history of ipsilateral acute ischemic stroke or transient ischemic attack (TIA) treated with either carotid artery stenting or endarterectomy was reviewed. Patient demographics, comorbidities, clinical presentation, treatment methodology, and outcomes at follow up were collected. Results: Among the 71 included patients (mean age 52.4 years, 44 (62.4%) female), 23 (32.4%) underwent CEA, and 48 (67.6%) underwent CAS. The most common presenting symptoms were hemibody numbness/weakness, aphasia, and gaze deviation. On average, patients had experienced 1.12 ± 0.7 strokes or TIAs before intervention, with a mean delay of 115 ± 224 days between initial stroke/TIA and intervention. The median preintervention modified Rankin Scale (mRS) score was 2. Perioperatively, one patient (1.41%) experienced stroke and none experienced myocardial infarction. During mean 14.8 (±29.2)-month follow up, one patient experienced asymptomatic recurrent stroke (1.41%). Median mRS at follow up was 1, and carotid artery stenting and endarterectomy demonstrated similar rates of postoperative complication and recurrent stroke rates. Conclusion: Our results suggest that endarterectomy and stenting are safe and efficacious for minimizing subsequent stroke risk in patients who have experienced stroke or TIA from carotid webbing, warranting further studies to determine the optimal timing and method of treatment.

17 June 2025 in Interventional Neuroradiology
Verified
Journal Article
Closed access
ATAnnie Trang
Annie Trang
CBClint Badger
Clint Badger
JMJose Marino
Jose Marino
SSSouvik Singha
Souvik Singha
SMShyam Majmundar
Shyam Majmundar
JCJacob Cherian
Jacob Cherian
Background: Balloon guide catheters (BGCs) can optimize recanalization in endovascular thrombectomies, but recent studies suggest that aspiration catheters sized closely to the target vessel can be effective for recanalization. Objective: To compare the outcomes, efficacy, and safety of a single-surgeon experience replacing BGCs with large distal platform (LDP) catheters. Methods: This is a retrospective study of patients with anterior circulation large vessel occlusion undergoing endovascular thrombectomies. Our study population was divided based on use of either the Zoom™ 0.088” LDP (Imperative Care, Inc., Campbell, CA, USA) or Walrus™ BGC (Q’Apel Medical, Fremont, CA, USA). Primary outcomes were the thrombectomy technique used, time from groin puncture to recanalization, first pass effect (FPE), degree of final reperfusion (modified treatment in cerebral infarction [mTICI]), postoperative complications, and all-cause mortality at 90 days. Results: We analyzed 48 cases: 27 with Walrus™ BGC and 21 with LDP. Contact aspiration was primarily used with LDP ( p < 0.001), while a stent-retriever-based technique was preferred with BGC ( p < 0.001). The median groin-to-recanalization time was shorter for the LDP cohort ( p = 0.001). Both cohorts achieved mTICI ≥ 2b in all cases, with more mTICI of 3 in the LDP cohort ( p = 0.38). The LDP cohort also had a greater FPE ( p = 0.034). Four cases with iatrogenic dissections were observed with Walrus™ BGC ( p = 0.12) and 2 cases with downstream emboli with using the LDP ( p = 0.19). All-cause mortality was similar between cohorts ( p > 0.99). Conclusion: The super-bore LDP offers a significant advantage over BGCs, achieving faster reperfusion times without compromising safety or recanalization effectiveness. Switching to super-bore 0.088” Zoom may enhance thrombectomy procedures.

29 December 2023 in Surgical Neurology International
Verified
Journal Article
Open access
JOJoshua Olexa
Joshua Olexa
ATAnnie Trang
Annie Trang
RFRebecca Flessner
Rebecca Flessner
MLMohammed Labib
Mohammed Labib
Background: Ventriculoperitoneal (VP) shunt placement is one of the most commonly performed neurosurgical procedures, yet failure rates remain very high. Surface landmarks are typically used to guide VP shunt placement, but they are not reliable in identifying the target anatomy. Augmented reality (AR) is a promising new technology that has the potential to improve the accuracy and effectiveness of neurosurgical procedures. We describe the use of AR for the surgical planning of a VP shunt. Case Description: A 62-year-old male with a history of subarachnoid hemorrhage presented with delayed hydrocephalus. A computed tomography scan was obtained that confirmed dilated ventricles, requiring a right VP shunt. The patient was brought to the operating room, where the AR system was used for visualization and planning. Conclusion: In this study, we describe the use of AR for VP shunt placement. The AR system consists of a Microsoft HoloLens 2 head-mounted display and a novel markerless registration system, which was used to register patient-specific 3D models onto the patient’s head for visualizing target anatomy and planning an operative approach. The AR system was used to plan the VP shunt placement in the operating room. This system is easy to use and provides a visualization of the patient’s anatomy, which can be used to plan an optimal trajectory. We believe that this has the potential to improve the accuracy and outcomes of VP shunt placements, and further studies are needed to characterize the system’s accuracy and benefits.

5 December 2023 in World Neurosurgery
Verified
Journal Article
Closed access
JOJoshua Olexa
Joshua Olexa
KWKonrad W. Walek
Konrad W. Walek
RFRebecca Flessner
Rebecca Flessner
ATAnnie Trang
Annie Trang
JSJesse Stokum
Jesse Stokum
GSGary Schwartzbauer
Gary Schwartzbauer