8 July 2026 in Journal of Equine Veterinary Science
This preliminary study aimed to evaluate the feasibility of thermal microchips as a non-invasive alternative for body temperature monitoring in dairy donkeys. Temperature was recorded in 11 jennies using thermal microchips implanted subcutaneously at the neck and read transcutaneous with an RFID scanner, a digital rectal thermometer, and an infrared thermographic camera directed at the neck over the microchip implantation site. Mean temperatures were 35.5 ± 0.82°C (microchip), 36.5 ± 0.59°C (rectal), and 36.0 ± 1.9°C (thermography). Bland-Altman analysis revealed that microchip readings were systematically lower than rectal temperatures by a mean of 1.01°C (95% LoA: -2.68 to 0.64°C), exceeding the clinically acceptable limit of 0.5°C (p = 0.03). Differences between microchip and thermography (bias: -0.49°C; 95% LoA: -5.20 to 4.22°C) and between rectal and thermography readings (bias: 0.52°C; 95% LoA: -3.35 to 4.41°C) were not statistically significant but exceeded acceptable agreement limits. The three methods are not interchangeable.