Katja Reinhard

Katja Reinhard

Auto-generated profile, based on publicly available information

Katja Reinhard

Neuroscience Department, Scuola Internazionale Superiore di Studi Avanzati

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 December 2014 in Nature Neuroscience
Verified
Journal Article
Open access
PDF file
ATAlexandra Tikidji-Hamburyan
Alexandra Tikidji-Hamburyan
KRKatja Reinhard
Katja Reinhard
HSHartwig Seitter
Hartwig Seitter
AHAnahit Hovhannisyan
Anahit Hovhannisyan
CPChristopher A Procyk
Christopher A Procyk
TMThomas A Münch
Thomas A Münch
Light increments and decrements are encoded in the retina by ON and OFF ganglion cells. The polarity of these cells' responses is thought to be fixed, but Tikidji-Hamburyan and colleagues now demonstrate in mouse and pig retina that they can change depending on ambient illuminance. For instance, an OFF cell can gain or lose an ON response at different light levels. Such changes in response polarity propagate to higher visual centers in vivo. The collective activity pattern of retinal ganglion cells, the retinal code, underlies higher visual processing. How does the ambient illuminance of the visual scene influence this retinal output? We recorded from isolated mouse and pig retina and from mouse dorsal lateral geniculate nucleus in vivo at up to seven ambient light levels covering the scotopic to photopic regimes. Across each luminance transition, most ganglion cells exhibited qualitative response changes, whereas they maintained stable responses within each luminance. We commonly observed the appearance and disappearance of ON responses in OFF cells and vice versa. Such qualitative response changes occurred for a variety of stimuli, including full-field and localized contrast steps and naturalistic movies. Our results suggest that the retinal code is not fixed but varies with every change of ambient luminance. This finding raises questions about signal processing within the retina and has implications for visual processing in higher brain areas.

27 November 2017 in Nature Communications
Verified
Journal Article
Open access
PDF file
ATAlexandra Tikidji-Hamburyan
Alexandra Tikidji-Hamburyan
KRKatja Reinhard
Katja Reinhard
RSRiccardo Storchi
Riccardo Storchi
JDJohannes Dietter
Johannes Dietter
HSHartwig Seitter
Hartwig Seitter
TMThomas A. Münch
Thomas A. Münch
Rod and cone photoreceptors support vision across large light intensity ranges. Rods, active under dim illumination, are thought to saturate at higher (photopic) irradiances. The extent of rod saturation is not well defined; some studies report rod activity well into the photopic range. Using electrophysiological recordings from retina and dorsal lateral geniculate nucleus of cone-deficient and visually intact mice, we describe stimulus and physiological factors that influence photopic rod-driven responses. We find that rod contrast sensitivity is initially strongly reduced at high irradiances, but progressively recovers to allow responses to moderate contrast stimuli. Surprisingly, rods recover faster at higher light levels. A model of rod phototransduction suggests that phototransduction gain adjustments and bleaching adaptation underlie rod recovery. Consistently, exogenous chromophore reduces rod responses at bright background. Thus, bleaching adaptation renders mouse rods responsive to modest contrast at any irradiance. Paradoxically, raising irradiance across the photopic range increases the robustness of rod responses.

21 November 2019 in eLife
Verified
Journal Article
Open access
KRKatja Reinhard
Katja Reinhard
CLChen Li
Chen Li
QDQuan Do
Quan Do
EBEmily G Burke
Emily G Burke
SHSteven Heynderickx
Steven Heynderickx
KFKarl Farrow
Karl Farrow
Using sensory information to trigger different behaviors relies on circuits that pass through brain regions. The rules by which parallel inputs are routed to downstream targets are poorly understood. The superior colliculus mediates a set of innate behaviors, receiving input from >30 retinal ganglion cell types and projecting to behaviorally important targets including the pulvinar and parabigeminal nucleus. Combining transsynaptic circuit tracing with in vivo and ex vivo electrophysiological recordings, we observed a projection-specific logic where each collicular output pathway sampled a distinct set of retinal inputs. Neurons projecting to the pulvinar or the parabigeminal nucleus showed strongly biased sampling from four cell types each, while six others innervated both pathways. The visual response properties of retinal ganglion cells correlated well with those of their disynaptic targets. These findings open the possibility that projection-specific sampling of retinal inputs forms a basis for the selective triggering of behaviors by the superior colliculus.

1 June 2021 in Neuron
Verified
Journal Article
Closed access
ASArnau Sans-Dublanc
Arnau Sans-Dublanc
ACAnna Chrzanowska
Anna Chrzanowska
KRKatja Reinhard
Katja Reinhard
DLDani Lemmon
Dani Lemmon
BNBram Nuttin
Bram Nuttin
KFKarl Farrow
Karl Farrow

28 August 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
KRKatja Reinhard
Katja Reinhard
ATAlexandra Tikidji-Hamburyan
Alexandra Tikidji-Hamburyan
HSHartwig Seitter
Hartwig Seitter
SISaad Idrees
Saad Idrees
MMMarion Mutter
Marion Mutter
TMThomas A. Münch
Thomas A. Münch
Multi-electrode arrays are a state-of-the-art tool in electrophysiology, also in retina research. The output cells of the retina, the retinal ganglion cells, form a monolayer in many species and are well accessible due to their proximity to the inner retinal surface. This structure has allowed the use of multi-electrode arrays for high-throughput, parallel recordings of retinal responses to presented visual stimuli, and has led to significant new insights into retinal organization and function. However, using conventional arrays where electrodes are embedded into a glass or ceramic plate can be associated with three main problems: (1) low signal-to-noise ratio due to poor contact between electrodes and tissue, especially in the case of strongly curved retinas from small animals, e.g. rodents; (2) insufficient oxygen and nutrient supply to cells located on the bottom of the recording chamber; and (3) displacement of the tissue during recordings. Perforated multi-electrode arrays (pMEAs) have been found to alleviate all three issues in brain slice recordings. Over the last years, we have been using such perforated arrays to study light evoked activity in the retinas of various species including mouse, pig, and human. In this article, we provide detailed step-by-step instructions for the use of perforated MEAs to record visual responses from the retina, including spike recordings from retinal ganglion cells and in vitro electroretinograms (ERG). In addition, we provide in-depth technical and methodological troubleshooting information, and show example recordings of good quality as well as examples for the various problems which might be encountered. While our description is based on the specific equipment we use in our own lab, it may also prove useful when establishing retinal MEA recordings with other equipment.

16 February 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
KRKatja Reinhard
Katja Reinhard
TMThomas A. Münch
Thomas A. Münch
The retinal output is the sole source of visual information for the brain. Studies in non-primate mammals estimate that this information is carried by several dozens of retinal ganglion cell types, each informing the brain about different aspects of a visual scene. Even though morphological studies of primate retina suggest a similar diversity of ganglion cell types, research has focused on the function of only a few cell types. In human retina, recordings from individual cells are anecdotal or focus on a small subset of identified types. Here, we present the first systematic ex-vivo recording of light responses from 342 ganglion cells in human retinas obtained from donors. We find a great variety in the human retinal output in terms of preferences for positive or negative contrast, spatio-temporal frequency encoding, contrast sensitivity, and speed tuning. Some human ganglion cells showed similar response behavior as known cell types in other primate retinas, while we also recorded light responses that have not been described previously. This first extensive description of the human retinal output should facilitate interpretation of primate data and comparison to other mammalian species, and it lays the basis for the use of ex-vivo human retina for in-vitro analysis of novel treatment approaches.