28 August 2002 in Journal of Agricultural and Food Chemistry
1 February 2003 in Applied Spectroscopy
Visible and near-infrared reflectance spectra have been examined for their ability to classify extra virgin olive oils from the eastern Mediterranean on the basis of their geographic origin. Classification strategies investigated were partial least-squares regression, factorial discriminant analysis, and k-nearest neighbors analysis. Discriminant models were developed and evaluated using spectral data in the visible (400–750 nm), near-infrared (1100–2498 nm), and combined (400–2498 nm) wavelength ranges. A variety of data pretreatments was applied. Best results were obtained using factorial discriminant analysis on raw spectral data over the combined wavelength range; a correct classification rate of 93.9% was obtained on a prediction sample set. Though the overall sample set was limited in numbers, these results demonstrate the potential of near-infrared spectroscopy to classify extra virgin olive oils on the basis of their geographic origin.
17 October 2010 in International Journal for Ion Mobility Spectrometry
1 September 2016 in Analytica Chimica Acta
The aim of data preprocessing is to remove data artifacts-such as a baseline, scatter effects or noise-and to enhance the contextually relevant information. Many preprocessing methods exist to deliver one or more of these benefits, but which method or combination of methods should be used for the specific data being analyzed is difficult to select. Recently, we have shown that a preprocessing selection approach based on Design of Experiments (DoE) enables correct selection of highly appropriate preprocessing strategies within reasonable time frames. In that approach, the focus was solely on improving the predictive performance of the chemometric model. This is, however, only one of the two relevant criteria in modeling: interpretation of the model results can be just as important. Variable selection is often used to achieve such interpretation. Data artifacts, however, may hamper proper variable selection by masking the true relevant variables. The choice of preprocessing therefore has a huge impact on the outcome of variable selection methods and may thus hamper an objective interpretation of the final model. To enhance such objective interpretation, we here integrate variable selection into the preprocessing selection approach that is based on DoE. We show that the entanglement of preprocessing selection and variable selection not only improves the interpretation, but also the predictive performance of the model. This is achieved by analyzing several experimental data sets of which the true relevant variables are available as prior knowledge. We show that a selection of variables is provided that complies more with the true informative variables compared to individual optimization of both model aspects. Importantly, the approach presented in this work is generic. Different types of models (e.g. PCR, PLS, …) can be incorporated into it, as well as different variable selection methods and different preprocessing methods, according to the taste and experience of the user. In this work, the approach is illustrated by using PLS as model and PPRV-FCAM (Predictive Property Ranked Variable using Final Complexity Adapted Models) for variable selection.
1 October 2005 in Applied Spectroscopy
The limits of quantitative multivariate assays for the analysis of extra virgin olive oil samples from various Greek sites adulterated by sunflower oil have been evaluated based on their Fourier transform (FT) Raman spectra. Different strategies for wavelength selection were tested for calculating optimal partial least squares (PLS) models. Compared to the full spectrum methods previously applied, the optimum standard error of prediction (SEP) for the sunflower oil concentrations in spiked olive oil samples could be significantly reduced. One efficient approach (PMMS, pair-wise minima and maxima selection) used a special variable selection strategy based on a pair-wise consideration of significant respective minima and maxima of PLS regression vectors, calculated for broad spectral intervals and a low number of PLS factors. PMMS provided robust calibration models with a small number of variables. On the other hand, the Tabu search strategy recently published (search process guided by restrictions leading to Tabu list) achieved lower SEP values but at the cost of extensive computing time when searching for a global minimum and less robust calibration models. Robustness was tested by using packages of ten and twenty randomly selected samples within cross-validation for calculating independent prediction values. The best SEP values for a one year's harvest with a total number of 66 Cretian samples were obtained by such spectral variable optimized PLS calibration models using leave-20-out cross-validation (values between 0.5 and 0.7% by weight). For the more complex population of olive oil samples from all over Greece (total number of 92 samples), results were between 0.7 and 0.9% by weight with a cross-validation sample package size of 20. Notably, the calibration method with Tabu variable selection has been shown to be a valid chemometric approach by which a single model can be applied with a low SEP of 1.4% for olive oil samples across three different harvest years.
1 August 2016 in The Analyst
Historically, advances in the field of ion mobility spectrometry have been hindered by the variation in measured signals between instruments developed by different research laboratories or manufacturers. This has triggered the development and application of chemometric techniques able to reveal and analyze precious information content of ion mobility spectra. Recent advances in multidimensional coupling of ion mobility spectrometry to chromatography and mass spectrometry has created new, unique challenges for data processing, yielding high-dimensional, megavariate datasets. In this paper, a complete overview of available chemometric techniques used in the analysis of ion mobility spectrometry data is given. We describe the current state-of-the-art of ion mobility spectrometry data analysis comprising datasets with different complexities and two different scopes of data analysis, i.e. targeted and non-targeted analyte analyses. Two main steps of data analysis are considered: data preprocessing and pattern recognition. A detailed description of recent advances in chemometric techniques is provided for these steps, together with a list of interesting applications. We demonstrate that chemometric techniques have a significant contribution to the recent and great expansion of ion mobility spectrometry technology into different application fields. We conclude that well-thought out, comprehensive data analysis strategies are currently emerging, including several chemometric techniques and addressing different data challenges. In our opinion, this trend will continue in the near future, stimulating developments in ion mobility spectrometry instrumentation even further.