Niels Kant

Niels Kant

Auto-generated profile, based on publicly available information

Niels Kant

Clinical Research Center, Rijnstate Hospital, Wagnerlaan 55, 6815 AD Arnhem, the Netherlands

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 December 2021 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Open access
PDF file
NKNiels Kant
Niels Kant
GPGuido M. Peters
Guido M. Peters
BVBrenda J. Voorthuis
Brenda J. Voorthuis
CGCatharina G. M. Groothuis-Oudshoorn
Catharina G. M. Groothuis-Oudshoorn
MKMark V. Koning
Mark V. Koning
CDCarine J. M. Doggen
Carine J. M. Doggen
Our aim was to determine the agreement of heart rate (HR) and respiratory rate (RR) measurements by the Philips Biosensor with a reference monitor (General Electric Carescape B650) in severely obese patients during and after bariatric surgery. Additionally, sensor reliability was assessed. Ninety-four severely obese patients were monitored with both the Biosensor and reference monitor during and after bariatric surgery. Agreement was defined as the mean absolute difference between both monitoring devices. Bland Altman plots and Clarke Error Grid analysis (CEG) were used to visualise differences. Sensor reliability was reflected by the amount, duration and causes of data loss. The mean absolute difference for HR was 1.26 beats per minute (bpm) (SD 0.84) during surgery and 1.84 bpm (SD 1.22) during recovery, and never exceeded the 8 bpm limit of agreement. The mean absolute difference for RR was 1.78 breaths per minute (brpm) (SD 1.90) during surgery and 4.24 brpm (SD 2.75) during recovery. The Biosensor’s RR measurements exceeded the 2 brpm limit of agreement in 58% of the compared measurements. Averaging 15 min of measurements for both devices improved agreement. CEG showed that 99% of averaged RR measurements resulted in adequate treatment. Data loss was limited to 4.5% of the total duration of measurements for RR. No clear causes for data loss were found. The Biosensor is suitable for remote monitoring of HR, but not RR in morbidly obese patients. Future research should focus on improving RR measurements, the interpretation of continuous data, and development of smart alarm systems.

22 August 2024
Verified
Book Chapter
Open access
PDF file
NKNiels Kant
Niels Kant
SGSjoerd H. Garssen
Sjoerd H. Garssen
CVCarlijn A. Vernooij
Carlijn A. Vernooij
GMGert-Jan Mauritz
Gert-Jan Mauritz
MKMark V. Koning
Mark V. Koning
CDCarine J. M. Doggen
Carine J. M. Doggen
Adding continuous monitoring to usual care at an acute admission ward did not have an effect on the proportion of patients safely discharged. Implementation challenges of continuous monitoring may have contributed to the lack of effect observed.