Purpose: To retrospectively compare sensitivity and specificity of magnetic resonance (MR) imaging, three-dimensional (3D) MR spectroscopy, combined MR imaging and 3D MR spectroscopy, and carbon 11 (11C)-choline positron emission tomography (PET)/computed tomography (CT) for intraprostatic tumor sextant localization, with histologic findings as reference standard. Materials and Methods: The local ethics committee on human research provided approval and a waiver of informed consent for the retrospective study. MR imaging, 3D MR spectroscopy, and 11C-choline PET/CT results were retrospectively reviewed in 26 men with biopsy-proved prostate cancer (mean age, 64 years; range, 51–75 years) who underwent radical prostatectomy. Cancer was identified as areas of nodular low signal intensity on T2-weighted MR images. At 3D MR spectroscopy, choline-plus-creatine–to–citrate and choline-to-creatine ratios were used to distinguish healthy from malignant voxels. At PET/CT, focal uptake was visually assessed, and maximu...
2 February 2006 in European Journal of Nuclear Medicine and Molecular Imaging
Ultrasonography (US) is becoming popular for the assessment of adiposity, but no one has studied this tool in the light of its potential limitations. Our purpose was to investigate the impact of technical conditions on the evaluation of abdominal fat by US. Forty-five healthy males and 45 healthy females were consecutively enrolled in the study, randomly assigned to three groups equally distributed by sex, and examined accordingly to three technical points: fasting state (before and after meal [A]), breathing (expiration and inspiration [B]), and US equipment from different generations: 2003 and 1998 (C). Two blinded radiologists performed US in the these opposite conditions, acquiring five parameters representative of subcutaneous and visceral adiposity in two times. Student's t-test and Lin's correlation coefficient were used for statistical analysis to assess differences in the measures as well as in inter- and intra-observer agreements. The maximum and the only statistically significant changes were observed for intra-abdominal fat thickness regarding fasting state and breathing (Δ% = 24.1 ± 21.3 and Δ% = 9.2 ± 20.4, respectively; P < .0001). Reproducibility and repeatability, especially for visceral fat, were proved more stable in the following conditions: fasting state, expiration, and newer machine (2003). This article provides essential information and "range of confidence" for variations that can be expected from using different conditions in the measurement of abdominal adiposity by US to be carefully addressed as well as considered by US users and by researchers involving this technique in the field of body composition.