Lin Cheng

Lin Cheng

Auto-generated profile, based on publicly available information

Lin Cheng

Nari Group Corporation/State Grid Electric Power Research Institute, Nanjing, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2017
Verified
Conference Paper
Closed access
LCLin Cheng
Lin Cheng
MGMin Gao
Min Gao
XKXianbo Ke
Xianbo Ke
XSXiaoqiang Sun
Xiaoqiang Sun
Jun LiuJun Liu
Jun Liu
JLJia Lyu
Jia Lyu
With the development and maturity of DC technology, it will have great potential in modern active distribution network, smart grids, micro grids, and energy internets. Commutation Failure (CF) is one of the critical problems for DC system operations. The existing control strategies to mitigate CF focus mainly on the control of DC converters, such as directly controlling the firing angle of the inverter valves. A novel Combined AC-DC control method to mitigate CF is proposed in this study, which integrates the commutation failure preventive (CFPREV) control and DC current prediction and SVC phase separation control modules together. Simulation studies are carried out on the MATLAB/Simulink platform, the results show that the proposed combined AC-DC control strategy can effectively mitigate CFs and improve the dynamic performance of the HVDC system.

4 November 2020 in IEEE Access
Verified
Journal Article
Open access
HWHao Wen
Hao Wen
LCLin Cheng
Lin Cheng
YJYi Jiang
Yi Jiang
TZTaiyun Zhu
Taiyun Zhu
ZCZhong Chen
Zhong Chen
JHJian Hao
Jian Hao
Oil-pressboard insulation in transformers is prone to surface tracking or creeping discharge during operation. The oil-pressboard interface is believed to be one of the weakest points in the insulation system. In this paper, AC flashover characteristic at the triple junction of the oil-pressboard interface under a slightly inhomogeneous electric field has been studied. The results showed that the creeping discharge always started at the triple junction, then developed along the pressboard (PB) surface, and finally reached the opposite electrode. The reason was that the triple junction was subjected to the maximum electric field strength. The field strength corresponding to the breakdown of the pure oil gap (POG) was decreased with the increment in the gap distance between electrodes due to the volume effect. As a comparison, the field strength corresponding to the breakdown for PB only changed slightly with the gap distance. Besides, the breakdown electric field of both POG and PB hardly changed when the electrode diameter increased. The above results could be applied to the inverse calculation and estimation of the flashover voltage levels under longer gap distances with any electrode diameter. Moreover, the relative position of the oil gap and PB could influence the flashover voltage levels. The breakdown voltage with PB directly contacting the ground electrode was 10% higher than that with PB directly contacting the high voltage electrode. This could be explained by the different charge behavior. The obtained results could provide a reference for the insulation margin design in ultra-high-voltage transformers.