This work tries to provide guidance for the development of new methods aiming at the direct analysis of solid samples or complex liquid materials using HR CS GFAAS.
1 May 2011 in Spectrochimica Acta Part B: Atomic Spectroscopy
Phosphorus is an element that is difficult to determine accurately by most analytical techniques. In particular, phosphorus determination by means of electrothermal atomic absorption spectrometry (ETAAS) has been traditionally hampered by (i) the practical inability of using phosphorus resonance lines; (ii) its complex chemical behaviour (e.g., formation of volatile compounds and a tendency to interact with graphite); and, particularly, (iii) the overlap observed between molecular and atomic phosphorus lines, which makes it very difficult to obtain reliable results when using line source-ETAAS. In this work, the potential of high resolution-continuum source ET spectrometry for the direct determination of phosphorus in biological solid samples is demonstrated. Two different methodologies, based on the monitoring of either atomic or molecular lines, were compared, paying special attention to the judicious selection of the chemical modifier and the temperature program that will be most adequate to the intended purpose. In order to enable atomic phosphorus monitoring, a high atomization temperature (2650 °C) and a combination of chemical modifiers consisting of palladium, ascorbic acid and tungsten (as permanent modifier) were used. On the other hand, when monitoring PO lines, tungsten coating and vaporization at only 1900 °C proved to be sufficient for attaining reliable results, although attention has to be paid to the possible effect of spectral interferences (e.g., NO lines). Both methods permitted the direct analysis of the samples under investigation, offering a high sample throughput (about 15–20 minutes per determination), good sensitivity (m0 around 5 ng and LODs at the µg g−1 level), RSD values in the 5–10% range, and straightforward calibration with aqueous standards.
19 September 2018 in Journal of Analytical Atomic Spectrometry
After more than a decade since its commercial introduction, high-resolution continuum source atomic/molecular absorption spectrometry may be facing a mid-life crisis. Certainly, it is no longer a novel technique full of unknown potential, so it would already be time to establish the fields for which it is most suitable. This is, however, not so simple for a number of reasons. In the first place, more than a technique what we are discussing herein is a type of instrumentation with the potential to use two different techniques (atomic or molecular absorption), making it somewhat unique. Furthermore, the two techniques have not been explored equally, and more research on the mechanisms of formation of diatomic molecules is clearly needed. In the second place, new possibilities have recently appeared in the literature that need to be weighed as well. And there is the still unfulfilled, but nowadays more technically feasible than ever, promise to significantly increase the multi-elemental capabilities. This review critically examines the main research areas currently explored (namely, (i) direct analysis of solids and complex liquid materials, and (ii) determination of non-metals at trace levels via monitoring of molecular species) as well as the new venues (specifically, (i) isotopic analysis via monitoring of molecular species, and (ii) selective detection, quantification and sizing of nanoparticles) while also considering new instrumental developments, in an attempt to properly place high-resolution continuum source atomic/molecular absorption spectrometry in the field of trace element and isotopic analysis.