Alexandre Lorenzi

Alexandre Lorenzi

Auto-generated profile, based on publicly available information

Alexandre Lorenzi

LEME/UFRGS

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2017 in Revista IBRACON de Estruturas e Materiais
Verified
Journal Article
Open access
PDF file
DADaniela Adamatti
Daniela Adamatti
ALA. Lorenzi
A. Lorenzi
JCJ. A. Chies
J. A. Chies
LFL.C.P. Silva Filho
L.C.P. Silva Filho
The application of Nondestructive Testing methods (NDT) may be an interesting strategy to monitor the condition state of reinforced concrete structures, especially when there are problems related to mixing, conveying or placing the concrete. Among the NDT methods, the Ultrasonic Pulse Velocity (UPV) has been one of the most used in various fields of civil engineering, due to the ease of operation, low cost, test velocity and low level of damage to the surface analyzed. This work aims to study the influence of certain technological variables in the results obtained through UPV tests. With this aim two large blocks were cast at the laboratory, with dimensions close to real concrete elements. One of the elements was reinforcement with steel meshes on both sides while the other was cast without reinforcement. Inside these elements objects were introduced to reproduce internal concrete flaws. To facilitate the analysis the results were represented by means of a surface mapping image technique and were also subjected to statistical analysis. Through the study it was demonstrated that the correct choice of test parameters is crucial to obtain a right interpretation of UPV results from real structures.

1 February 2025 in e-Journal of Nondestructive Testing
Verified
Journal Article
Open access
PDF file
F(Federal University of Rio Grande do Sul (UFRGS)
Federal University of Rio Grande do Sul (UFRGS)
ALAlexandre Lorenzi
Alexandre Lorenzi
LOLeonardo Covatti de Oliveira
Leonardo Covatti de Oliveira
TOTobias Pigatto Ottoni
Tobias Pigatto Ottoni
LRLucas Alexandre Reginatto
Lucas Alexandre Reginatto
LLLuciani Somensi Lorenzi.
Luciani Somensi Lorenzi.
Nondestructive testing (NDT) is increasingly being used in the construction industry for auxiliary inspection of concrete structures. One of the most used techniques is the measurement of the ultrasonic pulse velocity. In this paper, five reinforced concrete pillars were inspected using the ultrasonic echo of shear waves to create a cross-section tomography of the pillars. A 10 cm x 10 cm grid was used, amounting to 600 measurements. Observing a heterogeneity of the echo pulse velocities was possible, indicating possible pathological manifestations in the structural elements. The data collected generated a 3D image of the reflected interfaces of the component. The present article illustrates the application of ultrasonic tomography (UT) in evaluating the conservation state of reinforced concrete pillars.

24 July 2023 in Research Square
Verified
Preprint
Open access
PDF file
LRLucas Alexandre Reginato
Lucas Alexandre Reginato
ALAlexandre Lorenzi
Alexandre Lorenzi
LOLeonardo Covatti de Oliveira
Leonardo Covatti de Oliveira
LLLuciani Somensi Lorenzi
Luciani Somensi Lorenzi
LFLuiz Carlos Pinto da Silva Filho
Luiz Carlos Pinto da Silva Filho
Among the processes that accelerate the loss performance of reinforced concrete structures, considering their frequent occurrence and severity, reinforcement corrosion can be seen as one of the most important. A worrying factor is that most buildings in the Brazilian urban centers are between 40 and 50 years old, a time when repairs and maintenance become more routine. Therefore, the problems related to the corrosion of the reinforcements tend to accentuate in the coming years, and the identification of corrosion will play an important role. Thus, this research has the purpose to analyze the application of the diagnosis through potential corrosion techniques. For this, full-scale reinforced concrete beams were corrosion analyzed. Corrosion was stimulated by the Modified Immersion Accelerated Corrosion - CAIM method, at three levels of mass loss: 5, 10 and 15%. The diagnostic technique through the corrosion potential was applied, in which it was observed that there is uncertainty in the corrosion evaluation for the mass loss levels of 5 and 10%, resulting in a corrosion uncertainty interval, but at 15%, the potential technique proved to be satisfactory.

1 September 2023
Verified
Conference Paper
Open access
LRL. A. Reginato
L. A. Reginato
ALA. Lorenzi
A. Lorenzi
LLLuciani Somensi Lorenzi.
Luciani Somensi Lorenzi.
RFR. Forsthofer
R. Forsthofer
LOL. C. Oliveira
L. C. Oliveira
LTL. H. B. Tirado
L. H. B. Tirado
A avaliação da homogeneidade de diferentes tipos de estruturas através da tomografia ultrassônica tem sido foco de pesquisadores no Brasil. Por conta disso, o objetivo desta pesquisa foi avaliar a homogeneidade da estrutura de pilares de concreto armado utilizando o equipamento da marca PROCEQ®, modelo PUNDIT PL-200PE. O ensaio de tomografia ultrassônica foi realizado em uma das faces de pilares com diferentes características, utilizando um grid de 15 cm (horizontal) x 10 cm (vertical). As leituras foram realizadas no pilar a partir do fundo da laje. Após a análise dos resultados, foi possível identificar regiões com prováveis defeitos ou com possíveis falhas em mais de 70% das amostras avaliadas.

6 July 2026 in CONGRESSO BRASILEIRO DE PATOLOGIA DAS CONSTRUÇÕES (CBPAT)
Verified
Conference Paper
Open access
PDF file
LLLuciani Somensi Lorenzi.
Luciani Somensi Lorenzi.
ARAngelica Winter Rabaioli
Angelica Winter Rabaioli
LRLucas Alexandre Reginato
Lucas Alexandre Reginato
ALAlexandre Lorenzi
Alexandre Lorenzi
As Obras de Arte Especiais (OAEs) são ativos críticos para a mobilidade urbana, e sua degradação pode gerar riscos à segurança e impactos socioeconômicos relevantes. Este trabalho apresenta a inspeção de uma OAE em concreto armado localizada na Rua Voluntários da Pátria, em Porto Alegre/RS, motivada por ressaltos recorrentes nas juntas de dilatação e por indícios de intervenções sucessivas por recapeamentos. A metodologia combinou revisão bibliográfica, levantamento documental junto à gestora da obra e inspeção in loco baseada em avaliação visual e tátil, sem recursos especiais de acesso, seguindo as diretrizes da ABNT NBR 9452:2019. Foram registradas anomalias relacionadas a drenagem deficiente (drenos quebrados e obstruídos), umidade com eflorescências e biofilme, fissuração e lascamento de concreto com exposição e corrosão de armaduras, obstrução de aparelho de apoio, deterioração localizada de viga transversina e obstrução das juntas de dilatação. A classificação resultou em nota 3 (condição regular) no parâmetro estrutural e notas 2 (condição ruim) nos parâmetros funcional e de durabilidade. Recomenda-se a antecipação de inspeção especial por profissional habilitado, com ensaios complementares e priorização de intervenções de curto prazo voltadas à segurança do usuário e ao controle de agentes de deterioração.

6 July 2026 in CONGRESSO BRASILEIRO DE PATOLOGIA DAS CONSTRUÇÕES (CBPAT)
Verified
Conference Paper
Open access
PDF file
LLLuciani Somensi Lorenzi.
Luciani Somensi Lorenzi.
ALAlexandre Lorenzi
Alexandre Lorenzi
DKDario Lauro Klein
Dario Lauro Klein
Este trabalho apresenta resultados de ensaios de compressão excêntrica (e = 10 mm) em corpos de prova representativos da ligação painel-laje de um sistema de vedação vertical externa composto por painéis pré-fabricados de concreto armado com insertos metálicos soldados. Três corpos de prova (500 × 1000 × 100 mm) foram ensaiados em pórtico de carga com aplicação incremental de força (≈ 50 kN por etapa) até a perda de capacidade resistente. O Estado Limite de Serviço foi definido pela primeira fissura visível, que ocorreu entre 208 kN e 274 kN. O Estado Limite Último ocorreu entre 222 kN e 283 kN, com colapso associado à ruptura da solda na ligação entre o painel e o inserto metálico. Considerando-se, de forma conservadora, a transferência do peso próprio exclusivamente pelos insertos inferiores, as resistências medidas mostraram-se significativamente superiores às ações permanentes estimadas por inserto, indicando ampla margem de segurança frente à solicitação gravitacional. Os resultados destacam o papel do detalhamento e da execução da solda como aspectos determinantes do desempenho da conexão e fornecem subsídios experimentais para verificações de projeto e estratégias de inspeção de SVVE em painéis de concreto.