Erica P. McCune

Erica P. McCune

Auto-generated profile, based on publicly available information

Erica P. McCune

Department of Biomedical Engineering, Columbia University, New York, NY, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
CAChristian Aurup
Christian Aurup
JBJonas Bendig
Jonas Bendig
SBSamuel G. Blackman
Samuel G. Blackman
EMErica P. McCune
Erica P. McCune
SBSua Bae
Sua Bae
EKElisa Konofagou
Elisa Konofagou
Background: Focused ultrasound (FUS) is an emerging non-invasive technique for neuromodulation in the central nervous system (CNS). Functional ultrasound imaging (fUSI) leverages ultrafast Power Doppler Imaging (PDI) to detect changes in cerebral blood volume (CBV), which correlate well with neuronal activity and thus hold promise to monitor brain responses to FUS. Objective: Investigate the immediate and short-term effects of transcranial FUS neuromodulation in the brain with fUSI by characterizing hemodynamic responses. Methods: We designed a setup that aligns a FUS transducer with a linear array to allow immediate subsequent monitoring of the hemodynamic response with fUSI during and after FUS neuromodulation (FUS-fUSI) in lightly anesthetized mice. We investigated the effects of varying pressures and transducer positions on the hemodynamic responses. Results: We found that higher FUS pressures increase the size of the activated brain area, as well as the magnitude of change in CBV and could show that sham sonications did not produce hemodynamic responses. Unilateral sonications resulted in bilateral hemodynamic changes with a significantly stronger response on the ipsilateral side. FUS neuromodulation in mice with a cranial window showed distinct activation patterns that were frequency-dependent and different from the activation patterns observed in the transcranial model. Conclusion: fUSI is hereby shown capable of transcranially monitoring online and short-term hemodynamic effects in the brain during and following FUS neuromodulation

31 May 2023 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
EMErica P. McCune
Erica P. McCune
SLStephen A. Lee
Stephen A. Lee
EKElisa Konofagou
Elisa Konofagou
Focused ultrasound (FUS) peripheral neuromodulation has been linked to nerve displacement caused by the acoustic radiation force; however, the roles of cavitation and temperature accumulation on nerve modulation are less clear, as are the relationships between these three mechanisms of action. Temperature directly changes tissue stiffness and viscosity. Viscoelastic properties have been shown to affect cavitation thresholds in both theoretical and ex vivo models, but the direct effect of temperature on cavitation has not been investigated in vivo. Here, cavitation and tissue displacement were simultaneously mapped in response to baseline tissue temperatures of either 30°C or 38°C during sciatic nerve sonication in mice. In each mouse, the sciatic nerve was repeatedly sonicated at 1.1 MHz, 4 MPa peak-negative pressure, 5 ms pulse duration, and either 15 Hz or 30 Hz pulse repetition frequency for 10 s at each tissue temperature. Cavitation increased by 1.8-4.5 dB at a tissue temperature of 38°C compared to 30°C, as measured both by passive cavitation images and cavitation doses. Tissue displacement also increased by 1.3-1.8 μm at baseline temperatures of 38°C compared to 30°C. Histological findings indicated small increases in red blood cell extravasation in the 38°C baseline temperature condition compared to 30°C at both PRFs. A strong positive correlation was found between the inertial cavitation dose and displacement imaging noise, indicating the potential ability of displacement imaging to simultaneously detect inertial cavitation in vivo. Overall, tissue temperature was found to modulate both in vivo cavitation and tissue displacement, and thus both tissue temperature and cavitation can be monitored during FUS to ensure both safety and efficiency.

1 March 2026 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
EMErica P. McCune
Erica P. McCune
SBSamuel G. Blackman
Samuel G. Blackman
HKHermes Arytto Salles Kamimura
Hermes Arytto Salles Kamimura
EBEthan V. Bendau
Ethan V. Bendau
TSTalia D. Sachs
Talia D. Sachs
EKElisa Konofagou
Elisa Konofagou
Objective: This study investigated the attenuation of somatosensation in healthy subjects (n = 18) and subjects with carpal tunnel syndrome (CTS) (n = 6) via displacement-guided median nerve focused ultrasound (FUS). Somatosensory evoked potentials (SSEPs), pain, stiffness, and numbness were used as markers of sensation. Methods: Electroencephalography (EEG) was used to evaluate changes in electrically-induced SSEPs when paired with FUS. Subjects underwent 1000 (healthy population) or 500 (CTS population) surface electrical pulses at a maximum rate of 1 Hz to the median nerve to invoke a thumb twitch. Half of these pulses were paired with 5 ms of upstream median nerve sonication from a 1.1 MHz transducer at 1.8 or 2.9 MPa derated peak-positive pressure. Results: On-nerve sonication reduced the amplitude of SSEPs at both pressures. Reductions in beta and low-gamma frequency power occurred in healthy subjects and increases in alpha power occurred in CTS subjects. CTS subjects who received on-nerve sonication reported an average pain reduction of 40.6%. Off-nerve sonication did not reduce SSEP amplitudes or CTS symptoms. Median nerve displacement was correlated with SSEP reductions. Conclusion: Sonication of the median nerve can attenuate SSEPs, potentially in a displacement dose-driven manner. Symptom reduction in CTS subjects lasted 1-3 days post-procedure. Nerve targeting is essential to ensure therapeutic efficacy. Significance: This study is the first to demonstrate that peripheral nerve FUS modulates somatosensory-evoked potentials in humans. FUS attenuated neuropathic pain and stiffness related to median nerve entrapment, illustrating the potential analgesic effects of the procedure.