Robert Tamale Ssekitoleko

Robert Tamale Ssekitoleko

Auto-generated profile, based on publicly available information

Robert Tamale Ssekitoleko

Biomedical Engineering Unit, Department of Physiology, Makerere University, Kampala, Uganda

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2022 in BMC Research Notes
Verified
Journal Article
Open access
PDF file
HKHenry Fenekansi Kiwumulo
Henry Fenekansi Kiwumulo
HMHaruna Muwonge
Haruna Muwonge
CICharles Ibingira
Charles Ibingira
MLMichael Lubwama
Michael Lubwama
JKJohn Baptist Kirabira
John Baptist Kirabira
RSRobert Tamale Ssekitoleko
Robert Tamale Ssekitoleko
Objective: Green synthesized iron(III) oxide (Fe3O4) nanoparticles are gaining appeal in targeted drug delivery systems because of their low cost, fast processing and nontoxicity. However, there is no known research work undertaken in the production of green synthesized nano-particles from the Ugandan grown Moringa Oleifera (MO). This study aims at exploring and developing an optimized protocol aimed at producing such nanoparticles from the Ugandan grown Moringa. Results: While reducing ferric chloride solution with Moringa oleifera leaves, Iron oxide nanoparticles (Fe3O4-NPs) were synthesized through an economical and completely green biosynthetic method. The structural properties of these Fe3O4-NPs were investigated by Ultra Violet–visible (UV–Vis) spectrophotometry, X-ray diffraction (XRD), energy dispersive X-ray spectroscopy (EDX) and scanning electron microscopy (SEM). These nanoparticles exhibited UV–visible absorption peaks at 225 nm (nm) for the sixth dilution and 228 nm for the fifth dilution which indicated that the nanoparticles were photosensitive and the SEM study confirmed the spherical nature of these nanoparticles. The total synthesis time was approximately 5 h after drying the moringa leaves, and the average particle size was approximately 16 nm. Such synthesized nanoparticles can potentially be useful for drug delivery, especially in Low and Middle Income Countries (LMICs).

16 October 2020 in BMC Public Health
Verified
Journal Article
Open access
PDF file
RSRobert T. Ssekitoleko
Robert T. Ssekitoleko
SOSolomon Oshabaheebwa
Solomon Oshabaheebwa
IMIan G. Munabi
Ian G. Munabi
MTMartha S. Tusabe
Martha S. Tusabe
CNC. Namayega
C. Namayega
MJMoses L. Joloba
Moses L. Joloba
Background: With many medical equipment in hospitals coming in direct contact with healthcare workers, patients, technicians, cleaners and sometimes care givers, it is important to pay close attention to their capacity in harboring potentially harmful pathogens. The goal of this study was to assess the role that medical equipment may potentially play in hospital acquired infections in four public health facilities in Uganda. Methods: A cross-sectional study was conducted from December 2017 to January 2018 in four public health facilities in Uganda. Each piece of equipment from the neonatal department, imaging department or operating theatre were swabbed at three distinct points: a location in contact with the patient, a location in contact with the user, and a remote location unlikely to be contacted by either the patient or the user. The swabs were analyzed for bacterial growth using standard microbiological methods. Seventeen bacterial isolates were randomly selected and tested for susceptibility/resistance to common antibiotics. The data collected analyzed in STATA version 14. Results: A total of 192 locations on 65 equipment were swabbed, with 60.4% of these locations testing positive (116/192). Nearly nine of ten equipment (57/65) tested positive for contamination in at least one location, and two out of three equipment (67.7%) tested positive in two or more locations. Of the 116 contaminated locations 52.6% were positive for Bacillus Species, 14.7% were positive for coagulase negative staphylococcus, 12.9% (15/116) were positive for E. coli, while all other bacterial species had a pooled prevalence of 19.8%. Interestingly, 55% of the remote locations were contaminated compared to 66% of the user contacted locations and 60% of the patient contacted locations. Further, 5/17 samples were resistant to at least three of the classes of antibiotics tested including penicillin, glycylcycline, tetracycline, trimethoprim sulfamethoxazole and urinary anti-infectives. Conclusion: These results provides strong support for strengthening overall disinfection/sterilization practices around medical equipment use in public health facilities in Uganda. There’s also need for further research to make a direct link to the bacterial isolates identified and cases of infections recorded among patients in similar settings.

20 May 2022 in African Journal of Disability
Verified
Journal Article
Open access
PDF file
DRDafne Zuleima Morgado Ramirez
Dafne Zuleima Morgado Ramirez
BNBrenda Nakandi
Brenda Nakandi
RSRobert Ssekitoleko
Robert Ssekitoleko
HAHelen Ackers
Helen Ackers
EMErisa Mwaka
Erisa Mwaka
MDMaggie Donovan-Hall
Maggie Donovan-Hall
The journal is published for the purpose of advancing scholarship in disability studies and rehabilitation sciences in a uniquely African context. Widely read by scholars, professionals and students, it encourages scholarly exchange between all disciplines and academics from low, middle and high-income countries to work towards the improvement of human development and its practices across the continent.

1 November 2020 in Journal of Surgical Research
Verified
Journal Article
Closed access
MAMuthukurisil Arivoli
Muthukurisil Arivoli
ABArushi Biswas
Arushi Biswas
NBNolan Burroughs
Nolan Burroughs
PWPatrick Wilson
Patrick Wilson
CSCaroline Salzman
Caroline Salzman
TFTamara N. Fitzgerald
Tamara N. Fitzgerald

20 July 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
Alix ChadwellAlix Chadwell
Alix Chadwell
LKLaurence Kenney
Laurence Kenney
DHDavid Howard
David Howard
RSRobert T. Ssekitoleko
Robert T. Ssekitoleko
BNBrenda T. Nakandi
Brenda T. Nakandi
JHJohn Head
John Head
Using a shoulder harness and control cable, a person can control the opening and closing of a body-powered prosthesis prehensor. In many setups the cable does not pass adjacent to the shoulder joint center allowing shoulder flexion on the prosthetic side to be used for prehensor control. However, this makes cable setup a difficult compromise as prosthesis control is dependent on arm posture; too short and the space within which a person can reach may be unduly restricted, too long and the user may not be able to move their shoulder sufficiently to take up the inevitable slack at some postures and hence have no control over prehensor movement. Despite the fundamental importance of reachable workspace to users, to date there have been no studies in prosthetics on this aspect. Here, a methodology is presented to quantify the reduction in the reachable volume due to the harness, and to record the range-of-motion of the prehensor at a series of locations within the reachable workspace. Ten anatomically intact participants were assessed using a body-powered prosthesis simulator. Data was collected using a 3D motion capture system and an electronic goniometer. The harnessed reachable workspace was 38-85% the size of the unharnessed volume with participants struggling to reach across the body and above the head. Across all arm postures assessed, participants were only able to achieve full prehensor range-of-motion in 9%. The methodologies presented could be used to evaluate future designs of both body-powered and myoelectric prostheses.

1 February 2023 in Prosthesis
Verified
Journal Article
Open access
PDF file
AHAli Hussaini
Ali Hussaini
PKPeter Kyberd
Peter Kyberd
BMBenedict Mulindwa
Benedict Mulindwa
RSRobert Ssekitoleko
Robert Ssekitoleko
WKWilliam Keeble
William Keeble
DHDavid Howard
David Howard
Meeting the needs of persons with upper limb loss in Uganda requires an understanding of the needs and desires of the local population. The limitations of resources and accessibility for the individual gave rise to a focused design methodology for delivering a culturally acceptable solution using 3D Printing technology. A series of co-design activities were held in Uganda and provided direct feedback to drive the design of two prototypes based on acceptable aesthetics and priority Activities of Daily Living. Two terminal device prototypes were 3D printed in the UK. These can be directly attached to a standard proximal socket thread. The passive hand was printed in a flexible filament and the prehensor was printed in a durable impact resistant material. Local researchers in Uganda have similar 3D printers, filaments, and assembly hardware, which allowed for concurrent development and refinement of the prototypes. Local participation provides a rich user feedback environment to understand which elements of prosthetic device design are integral to delivering acceptable prosthetics solutions for fabrication in Uganda. 3D printing can provide a viable route to addressing the needs of the user. The proposed terminal devices are now in the process of being printed locally for field testing.