Simone Nascimento

Simone Nascimento

Auto-generated profile, based on publicly available information

Simone Nascimento

Agilent Technologies Brasil, São Paulo, São Paulo, Brazil

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Journal of the Brazilian Chemical Society
Verified
Journal Article
Closed access
SNSimone Nascimento
Simone Nascimento
Quezia Bezerra CassQuezia Bezerra Cass
Quezia Bezerra Cass
In this work, we report a method to quantify methylparaben, ethylparaben, propylparaben and butylparaben in urban waters of São Carlos (São Paulo State, Brazil) by online solid phase extraction-liquid chromatography tandem mass spectrometry (SPE-LC-MS/MS) system. The method achieved ng L-1 limits with good accuracy and precision (internal standards for each paraben were used). The total run cycle time takes 9.5 min per sample including the extraction, cleanup and columns conditioning cycles, lower collection volumes of urban water and solvent usage. The SPE cartridge applied showed robustness allowing over 500 sample injections (800 μL each) with good chromatographic performance. This study findings included the detection of parabens in samples in São Carlos.

22 August 2026 in Talanta
Verified
Journal Article
Open access
ACAlmir Custodio
Almir Custodio
NCNathália dos Santos Conceição
Nathália dos Santos Conceição
JAJoão Victor Borges Assis
João Victor Borges Assis
SNSimone Nascimento
Simone Nascimento
Monica Rodrigues Ferreira MachadoMonica Rodrigues Ferreira Machado
Monica Rodrigues Ferreira Machado
ACAndrea Chaves
Andrea Chaves
This study demonstrates the feasibility of direct analysis in real-time mass spectrometry (DART-MS) for rapid pesticide residues screening in aquatic ecosystems, highlighting the application of fish scales as a non-lethal biological matrix. For this purpose, multivariate approaches were employed to optimize the significant variables of the DART-MS method. The optimal conditions included a grid voltage of 150 V, a gas temperature of 200 °C, and the distance between the source and the mass spectrometer inlet of 3.2 cm. The DART-MS method demonstrated excellent performance for determination of ten pesticides in river water, achieving limits of quantification of 10 ng mL-1 and outstanding precision and accuracy. In addition, the quantitative performance of the DART-MS approach was evaluated for atrazine determination in fish plasma, showcasing its applicability to complex biological matrices following a simple sample preparation procedure. In addition, the direct analysis of fish scales enabled the rapid detection of pesticides without prior sample preparation. Overall, this proof-of-concept study demonstrates the applicability of DART-MS for pesticide monitoring in complementary aquatic matrices, including river water, plasma, and fish scales, while establishing fish scales as a promising matrix for environmental screening.