In this paper, we report an anomalous behavior of residual stress in epoxy resin insulation, which decreased with elevated cooling rate from an initial temperature below the glass transition temperature ( T g ). It was found that an increased cooling rate from 9 K/h to 120 K/h led to a decreased residual stress by 37%. Further results of dielectric relaxation and volumetric strain suggest the physical aging as the origin of this anomalous residual stress behavior, which resulted in enhanced chain relaxation on the micro level and volumetric shrinkage on the macro level. It is suggested that the larger residual stress is caused by both greater interaction between chains and larger volumetric shrinkage in the specimens with lower cooling rate. In addition, shortened cooling time also induced insufficient chain curling and thus increased free volume, which can be further supported by enhanced charge mobility and lowered DC breakdown strength. A 13% decrease in breakdown strength and a 38% increase in the charge mobility were found provided the cooling rate enhanced from 9 K/h to 120 K/h. This work proposed a new comprehending into the residual stress from curing cooling process and corresponding dielectric properties of epoxy resin insulation.
To efficiently and economically assess the insulating condition of widely used cross-linked polyethylene (XLPE) power cables, a non-destructive method for quantitatively predicting breakdown properties based on near-infrared (NIR) spectroscopy is proposed in this work. The NIR spectra of 24 XLPE samples with different aging conditions was established for calibration set. 40 key wavelengths near 1715, 1730, 1750, and 1763 nm strongly associated with breakdown strength were selected among 301 wavelengths by competitive adaptive reweighted sampling (CARS). The selected wavelengths are proved to be related with crystallinity which is positively correlated with breakdown strength. Further results of surface potential decay (SPD) reveal that breakdown strength is modulated by deep trap energy level which is positively correlated with the intensities at 1730 and 1763 nm. On that basis, a back-propagation (BP) neural network model with an R2 value of 0.96 and a relative RMSE of 3.20% was constructed using these wavelengths, achieving better predicting abilities than the models without CARS. It also achieves only 1.34% error in predicting the breakdown strength of XLPE samples from cables that have been in service for 6 different times. This work provides an accurate and efficient method for evaluating insulating condition of power cables.