Denali Boon

Denali Boon

Auto-generated profile, based on publicly available information

Denali Boon

Johns Hopkins Bloomberg School of Public Health

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 April 2020 in medRxiv
Verified
Preprint
Open access
PDF file
LKLauren M Kucirka
Lauren M Kucirka
SLStephen A Lauer
Stephen A Lauer
OLOliver Laeyendecker
Oliver Laeyendecker
DBDenali Boon
Denali Boon
JLJustin Lessler
Justin Lessler
SARS-CoV-2 RT-PCR based tests are being used to “rule out” infection among high-risk individuals such as exposed inpatients and healthcare workers. It is critical to understand how the predictive value of the test varies with time from exposure and symptom onset in order to avoid being falsely reassured by negative tests. As such, the goal of our study was to estimate the false negative rate by day since infection. We used previously published data on RT-PCR sensitivity on samples derived from nasal swabs by day since symptom onset (n=633) and fit a cubic polynomial spline to calculate the false negative rate by day since exposure and symptom onset. Over the four days of infection prior to the typical time of symptom onset (day 5) the probability of a false negative test in an infected individual falls from 100% on day one (95% CI 69-100%) to 61% on day four (95% CI 18-98%), though there is considerable uncertainty in these numbers. On the day of symptom onset, the median false negative rate was 39% (95% CI 16-77%). This decreased to 26% (95% CI 18-34%) on day 8 (3 days after symptom onset), then began to rise again, from 27% (95% CI 20-34%) on day 9 to 61% (95% CI 54-67%) on day 21. Care must be taken when interpreting RT-PCR tests for SARS-CoV-2 infection, particularly if performed early in the course of infection, when using these results as a basis for removing precautions intended to prevent onward transmission. If there is high clinical suspicion, patients should not be ruled out on the basis of RT-PCR alone, and the clinical and epidemiologic situation should be carefully considered.

2 September 2020 in medRxiv
Verified
Preprint
Open access
PDF file
EPEshan Patel
Eshan Patel
EBEvan M. Bloch
Evan M. Bloch
WCWilliam Clarke
William Clarke
YHYu-Hsiang Hsieh
Yu-Hsiang Hsieh
DBDenali Boon
Denali Boon
OLOliver Laeyendecker
Oliver Laeyendecker
Accurate serological assays to detect antibodies to SARS-CoV-2 are needed to characterize the epidemiology of SARS-CoV-2 infection and identify potential candidates for COVID-19 convalescent plasma (CCP) donation. This study compared the performance of commercial enzyme immunoassays (EIAs) to detect IgG or total antibodies to SARS-CoV-2 and neutralizing antibodies (nAb). The diagnostic accuracy of five commercially available EIAs (Abbott, Euroimmun, EDI, ImmunoDiagnostics, and Roche) to detect IgG or total antibodies to SARS-CoV-2 was evaluated from cross-sectional samples of potential CCP donors that had prior molecular confirmation of SARS-CoV-2 infection for sensitivity (n=214) and pre-pandemic emergency department patients for specificity (n=1,102). Of the 214 potential CCP donors, all were sampled >14 days since symptom onset and only a minority had been hospitalized due to COVID-19 (n=16 [7.5%]); 140 potential CCP donors were tested by all five EIAs and a microneutralization assay. When performed according to the manufacturers’ protocol to detect IgG or total antibodies to SARS-CoV-2, the sensitivity of each EIA ranged from 76.4% to 93.9%, and the specificity of each EIA ranged from 87.0% to 99.6%. Using a nAb titer cutoff of ≥160 as the reference positive test (n=140 CCP donors), the empirical area under receiver operating curve of each EIA ranged from 0.66 (Roche) to 0.90 (Euroimmun). Commercial EIAs with high diagnostic accuracy to detect SARS-CoV-2 antibodies did not necessarily have high diagnostic accuracy to detect high nAbs. Some but not all commercial EIAs may be useful in the identification of individuals with high nAbs in convalescent individuals.