Ahmed Kiser

Ahmed Kiser

Auto-generated profile, based on publicly available information

Ahmed Kiser

North South University

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2026 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
AKAhmed Kiser
Ahmed Kiser
MIMd Tarikul Islam
Md Tarikul Islam
JHJubair Ibn Omar Hamza
Jubair Ibn Omar Hamza
SDSumaiya Tabassum Dipty
Sumaiya Tabassum Dipty
SASayed Salman Aziz
Sayed Salman Aziz
ZMZaid Bin Mahbub
Zaid Bin Mahbub
Pulsed electromagnetic fields (PEMF) have been widely studied for vascular and microcirculatory modulation, yet their effects on pulsatile hemodynamic organization remain poorly characterized. It is also unclear whether reversing field direction under otherwise comparable exposure conditions can alter vascular waveform behavior. This study investigated acute direction-dependent responses to PEMF using Doppler ultrasound and photoplethysmography (PPG). Twenty healthy volunteers underwent PEMF exposure (10 Hz, 100 µs pulse width, 15 V) over the brachial artery with the coil in two opposing orientations, such that the local induced electric-field component along the arterial axis was directed either with (Forward) or against (Reverse) physiological blood flow. Downstream responses were assessed using radial artery Doppler and index-finger PPG. Participant-level feature summaries were analyzed using paired Wilcoxon signed-rank tests with Benjamini–Hochberg false-discovery-rate correction, including direct comparison of baseline-corrected Forward and Reverse responses, complemented by descriptive kernel-density L1 (KDE-L1) analysis. PPG showed the clearest participant-level responses. Six Forward features involving temporal, morphological, and pulse-area characteristics remained false discovery rate (FDR)-significant ( q = 0.018 − 0.037 ), whereas five Reverse features involving systolic amplitude, notch timing, and spectral organization remained significant ( q = 0.003 − 0.012 ). Direct Forward–Reverse comparison identified significant differences in eight PPG features spanning amplitude, area, temporal, and spectral domains ( q = 0.005 − 0.029 ). Doppler showed a more selective response, with Forward cardiac cycle duration (CCD) remaining FDR-significant ( q = 0.014 ), together with broader KDE-L1 redistribution of arterial velocity-waveform characteristics. These findings demonstrate orientation-sensitive peripheral pulse-wave responses together with complementary arterial waveform changes, supporting field direction as a potentially relevant exposure parameter in vascular PEMF research.

28 July 2026 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
Zakaria Shams SiamZakaria Shams Siam
Zakaria Shams Siam
Rubyat Tasnuva HasanRubyat Tasnuva Hasan
Rubyat Tasnuva Hasan
MMM A Masud
M A Masud
RIRashedul Islam
Rashedul Islam
Muhammad E. H. ChowdhuryMuhammad E. H. Chowdhury
Muhammad E. H. Chowdhury
ZMZaid Bin Mahbub
Zaid Bin Mahbub
Prediction of motor nerve conduction velocity distribution (CVD) from compound muscle action potential (CMAP), commonly referred to as the inverse problem of nerve conduction, provides a useful computational approach for investigating peripheral neuropathies. Only limited studies have attempted to estimate CVD using continuous parametric models because deterministic optimization approaches, such as gradient-based methods, often face computational challenges when nonlinear CVD functions are considered. In this study, we propose a phenomenological, metaheuristic-based inverse modeling framework for simultaneous estimation of motor unit action potential (MUAP) waveform characteristics and CVD from recorded CMAP signals. The MUAP waveform was modeled using a modified piecewise Hermite polynomial formulation, while the CVD was represented using a modified single Weibull distribution. The mean squared error (MSE) between the recorded and reconstructed CMAP signals was used as the objective function and minimized using genetic algorithm (GA) and grey wolf optimizer (GWO) approaches. The proposed framework efficiently estimated MUAP and CVD parameters with low reconstruction error (MSE < 0.28) for synthetic CMAP signals and demonstrated stable performance when tested on both synthetic and in-vivo CMAP datasets. The maximum computational runtime observed in this study was approximately 2.73 min. Additional analyses showed that GWO provided more consistent convergence than GA and a gradient-based nonlinear least-squares baseline, while noise-robustness testing demonstrated stable reconstruction over multiple signal-to-noise ratio conditions. Group-level comparison of reconstructed CVD parameters further showed distinguishable differences between non-neuropathic and diabetic neuropathy subgroups. The results suggest that the proposed inverse framework provides a computationally efficient and non-invasive approach for analyzing motor nerve conduction characteristics from CMAP recordings and may support quantitative evaluation of peripheral neuropathies.