Ayooluwa S. Ayoola

Ayooluwa S. Ayoola

Auto-generated profile, based on publicly available information

Ayooluwa S. Ayoola

Wayne State University School of Medicine, Detroit, Michigan

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2020 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
KBKamil Bober
Kamil Bober
AKAllen Kadado
Allen Kadado
MCMichael Charters
Michael Charters
AAAyooluwa Ayoola
Ayooluwa Ayoola
TNTrevor North
Trevor North

18 March 2022 in Journal of the American Academy of Orthopaedic Surgeons
Verified
Journal Article
Closed access
AKAllen Kadado
Allen Kadado
JSJonathan H. Shaw
Jonathan H. Shaw
AAAyooluwa S. Ayoola
Ayooluwa S. Ayoola
NANoel Akioyamen
Noel Akioyamen
WNW. Trevor North
W. Trevor North
MCMichael A Charters
Michael A Charters
Background: This study investigates the effects of preoperative carbohydrate-rich drinks on postoperative outcomes after primary total knee arthroplasty. Methods: We prospectively randomized 153 consecutive patients undergoing primary total knee arthroplasty at one institution. Patients were assigned to one of three groups: group A (50 patients) received a carbohydrate-rich drink; group B (51 patients) received a placebo drink; and group C (52 patients) did not receive a drink (control). All healthcare personnel and patients were blinded to group allocation. Controlling for demographics, we analyzed the rate of postoperative nausea and vomiting, length of stay, opiate consumption, pain scores, serum glucose, adverse events, and intraoperative and postoperative fluid intake. Results: Demographics and comorbidities were similar among the groups. There were no significant differences in surgical interventions or experience. Surgical fluid intake and total blood loss were similar among the three groups (P = 0.47, P = 0.23). Furthermore, acute postoperative outcomes (ie, pain, episodes of nausea, and length of stay) were similar across all three groups. There were no significant differences in adverse events between the three groups (P = 0.13). There was a significant difference in one-time postoperative bolus between the three groups (P = 0.02), but after multivariate analysis, it did not demonstrate significance. None of the intervention group were readmitted, whereas 5.9% and 11.5% were readmitted in the placebo and control groups, respectively (P = 0.047). The chance of 90-day readmission was reduced in group A compared with group C (odds ratio, 0.08; 95% confidence interval, 0.01 to 0.72; P = 0.02). There were no differences in other postoperative outcome measurements. Conclusion: This randomized controlled trial demonstrated that preoperative carbohydrate loading does not improve immediate postoperative outcomes, such as nausea and vomiting; however, it demonstrated that consuming fluid preoperatively proved no increased risk of adverse outcomes and there was a trend toward decrease of one-time boluses postoperatively. Clinical Trials Registry: NCT03380754

3 March 2022 in The Journal of Knee Surgery
Verified
Journal Article
Closed access
PDF file
EKElizabeth A. Klag
Elizabeth A. Klag
VLVincent A. Lizzio
Vincent A. Lizzio
MCMichael A. Charters
Michael A. Charters
AAAyooluwa S. Ayoola
Ayooluwa S. Ayoola
LWLuke Wesemann
Luke Wesemann
WNW. Trevor North
W. Trevor North
Templating prior to total hip arthroplasty is a widely adopted practice that aims to improve operative efficiency and reduce clinical outliers. Predicting implant size before total knee arthroplasty (TKA), although less common, could increase operating room efficiency by reducing necessary equipment needed for the procedure. This study compared templating accuracy in TKA using two-dimensional (2D) digital radiographs to a novel imaging technology that generates a three-dimensional (3D) model from these 2D radiographs. Two hundred and two robotic-assisted primary TKA surgical cases using Persona Knee System (Zimmer Biomet, Warsaw, IN) were retrospectively analyzed. For all cases, 3D templating was completed preoperatively using a novel radiographic image acquisition protocol. Using the same radiographs, the knee was templated using a 2D digital templating program. All surgeons were blinded to the final implant sizes, and all templating was done independently. The accuracy of predictions within ± 1 from the final implant size was determined for the femoral and tibial components. The accuracy (within 1 size) of tibial size predictions was comparable between attending surgeons and residents (87 vs. 82%, p = 0.08), but attending surgeons more accurately predicted the femoral size (77 vs. 60%, p < 0.05). The 2D to 3D imaging technology more accurately predicted both tibial and femoral sizes compared with the attending surgeons (99.5 vs. 87%, p < 0.05; 84% vs. 77%, p < 0.05). However, the imaging technology, attending surgeons, and residents were all more likely to overestimate femur size (p < 0.05). Moreover, the 3D imaging technology predicted the exact tibial component size in 93.1% of cases, which was significantly greater compared with residents (40%, p < 0.01) and attending surgeons (53%, p < 0.01). The 2D to 3D imaging technology more accurately predicted tibial and femoral component sizes compared with 2D digital templating done by surgeons. All templating predictions were more accurate for the tibial implant size than for the femoral size. The increased accuracy of implant size predictions from this 3D templating technology has the potential to improve intraoperative efficiency and minimize costs and surgical time.

18 August 2023 in Seminars in Arthroplasty: JSES
Verified
Journal Article
Closed access
NKNoah A. Kuhlmann
Noah A. Kuhlmann
SFSreten Franovic
Sreten Franovic
GBGabriel B. Burdick
Gabriel B. Burdick
DHDanielle S. Hanson
Danielle S. Hanson
MDMiriam E. Dash
Miriam E. Dash
SMStephanie J. Muh
Stephanie J. Muh