16 July 2021 in IEEE Transactions on Instrumentation and Measurement
Partial discharge (PD) detection and localization is one of the most effective methods in gas-insulated transmission lines (GIL) insulation fault diagnosis, which is important to the early troubleshooting and safe operation. Compared with the widely used ultrahigh frequency (UHF) and acoustic PD localization methods, the PD localization method based on optical signals has good resistance to electromagnetic and acoustic interference. However, the current optical localization method comes with several shortcomings: narrow detection range, requiring field experiments to accumulate data, and installing a large number of sensors, which renders low feasibility. Therefore, this article proposes a PD localization method utilizing virtual sensors (VSs) and optical simulation fingerprint. Based on the idea of the digital twin, this method constructs a fingerprint database through optical PD simulation in an equal-sized GIL simulation model, which solves the difficulty of fingerprint collection in actual equipment. Meanwhile, this article predicts the detection value of the VS through the adaptive neuro-fuzzy inference system (ANFIS) to greatly reduce the installation of the actual sensor (AS). Finally, through the support vector machines (SVMs) algorithm, the detection fingerprint that includes the virtual and actual detection values matches with the fingerprint database. The location corresponding to the optimal matching result is recorded as the localization result. As experiments have shown, the average localization error of the proposed method is 19.69 mm, which is 54.8% lower than the one without VSs under the same conditions. The results reveal that this method compensates for the loss of localization accuracy caused by the reduction of ASs, which embodies value in practice.
19 January 2026 in IEEE Transactions on Dielectrics and Electrical Insulation
Accurate localization of partial discharge (PD) in power transformers is critical for condition monitoring and fault prevention. However, localization algorithms are primarily validated through laboratory experiments or offline tests, making it difficult to assess their performance accurately in operational transformers. In this paper, a method is proposed to evaluate the positioning accuracy of PD localization algorithms by injecting pulse current into an ultra-high frequency (UHF) sensor to simulate PD source. The proposed method is first validated on an in-service 220 kV transformer equipped with six built-in UHF sensors. The results show that this method is safe, controllable, and capable of flexibly changing the location of PD. Furthermore, extensive experiments are conducted on another 220 kV transformer equipped with 18 built-in UHF sensors to systematically analyze the impact of sensor number and placement on the localization error of time difference of arrival (TDOA). It is found that increasing the number of sensors can reduce the likelihood of large positioning errors to some extent. But for highly accurate positioning, the best result is achieved when using five or six sensors. In terms of sensor placement, TDOA-based localization is less robust when sensors are placed on the same side or in adjacent areas. Uniform placement on all sides of the transformer can improve robustness, but it is difficult to achieve a high accuracy of the positioning error within 0.5m.