Hui Wang

Hui Wang

Auto-generated profile, based on publicly available information

Hui Wang

Department of Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 July 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YZYiming Zang
Yiming Zang
YQyong qian
yong qian
HWHui Wang
Hui Wang
AXAntian Xu
Antian Xu
XZXiaoli Zhou
Xiaoli Zhou
XJXiuchen Jiang
Xiuchen Jiang
Partial discharge (PD) detection and localization is one of the most effective methods in gas-insulated transmission lines (GIL) insulation fault diagnosis, which is important to the early troubleshooting and safe operation. Compared with the widely used ultrahigh frequency (UHF) and acoustic PD localization methods, the PD localization method based on optical signals has good resistance to electromagnetic and acoustic interference. However, the current optical localization method comes with several shortcomings: narrow detection range, requiring field experiments to accumulate data, and installing a large number of sensors, which renders low feasibility. Therefore, this article proposes a PD localization method utilizing virtual sensors (VSs) and optical simulation fingerprint. Based on the idea of the digital twin, this method constructs a fingerprint database through optical PD simulation in an equal-sized GIL simulation model, which solves the difficulty of fingerprint collection in actual equipment. Meanwhile, this article predicts the detection value of the VS through the adaptive neuro-fuzzy inference system (ANFIS) to greatly reduce the installation of the actual sensor (AS). Finally, through the support vector machines (SVMs) algorithm, the detection fingerprint that includes the virtual and actual detection values matches with the fingerprint database. The location corresponding to the optimal matching result is recorded as the localization result. As experiments have shown, the average localization error of the proposed method is 19.69 mm, which is 54.8% lower than the one without VSs under the same conditions. The results reveal that this method compensates for the loss of localization accuracy caused by the reduction of ASs, which embodies value in practice.

15 October 2020
Verified
Conference Paper
Closed access
YZYiming Zang
Yiming Zang
YQyong qian
yong qian
HWHui Wang
Hui Wang
AXAntian Xu
Antian Xu
Gehao ShengGehao Sheng
Gehao Sheng
XJXiuchen Jiang
Xiuchen Jiang
As gas-insulated transmission line (GIL) is widely used, the partial discharge (PD) phenomenon that occurs during their operation is one of the main reasons for the deterioration of their insulation status. Therefore, the detection and localization of PD in the GIL plays an important role in ensuring the safe and stable operation of the equipment. At present, the PD localization methods for GIL are mainly ultrahigh frequency (UHF) method and ultrasonic method, while these methods are susceptible to mechanical vibration and electromagnetic interference. Optical detection, as a sensitive and effective PD detection method, is rarely used in the field of GIL PD localization. Accordingly, this paper proposes a GIL PD localization method based on optical PD simulation and machine learning. This method establishes a simulation model that is exactly the same as the actual GIL in terms of structure, size and sensor arrangement, where the PD optical simulation experiment is performed to build a PD simulation fingerprint database. Each fingerprint in the fingerprint database corresponds to a PD source location information. Based on this, the PSO-SVM machine learning algorithm is used to match the actual PD fingerprints with the fingerprints in the simulation fingerprint database to obtain the localization results. This method overcomes the difficulty of collecting a large amount of field data to build a fingerprint database in the existing optical fingerprint localization method through simulation. And the structure of GIL in the simulation can be customized according to the actual equipment, while the workload of obtaining the fingerprint database through actual experiments is very heavy for different types of equipment. Through experimental verification, this paper selects 12 typical locations of PD sources in the GIL experimental tank for testing. The average localization error is 10.58mm.

19 January 2026 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
ZWZirui Wu
Zirui Wu
CPCheng Pan
Cheng Pan
PZPan Zijun
Pan Zijun
QZQingdong Zhu
Qingdong Zhu
HWHui Wang
Hui Wang
JTJu Tang
Ju Tang
Accurate localization of partial discharge (PD) in power transformers is critical for condition monitoring and fault prevention. However, localization algorithms are primarily validated through laboratory experiments or offline tests, making it difficult to assess their performance accurately in operational transformers. In this paper, a method is proposed to evaluate the positioning accuracy of PD localization algorithms by injecting pulse current into an ultra-high frequency (UHF) sensor to simulate PD source. The proposed method is first validated on an in-service 220 kV transformer equipped with six built-in UHF sensors. The results show that this method is safe, controllable, and capable of flexibly changing the location of PD. Furthermore, extensive experiments are conducted on another 220 kV transformer equipped with 18 built-in UHF sensors to systematically analyze the impact of sensor number and placement on the localization error of time difference of arrival (TDOA). It is found that increasing the number of sensors can reduce the likelihood of large positioning errors to some extent. But for highly accurate positioning, the best result is achieved when using five or six sensors. In terms of sensor placement, TDOA-based localization is less robust when sensors are placed on the same side or in adjacent areas. Uniform placement on all sides of the transformer can improve robustness, but it is difficult to achieve a high accuracy of the positioning error within 0.5m.