S. J. D. Dann

S. J. D. Dann

Auto-generated profile, based on publicly available information

S. J. D. Dann

Central Laser Facility

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 December 2020 in Nature Communications
Verified
Journal Article
Open access
PDF file
RSR. J. Shalloo
R. J. Shalloo
SDS. J. D. Dann
S. J. D. Dann
JGJ.-N. Gruse
J.-N. Gruse
CUC. I. D. Underwood
C. I. D. Underwood
AAA. F. Antoine
A. F. Antoine
MSM. J. V. Streeter
M. J. V. Streeter
Laser wakefield accelerators promise to revolutionize many areas of accelerator science. However, one of the greatest challenges to their widespread adoption is the difficulty in control and optimization of the accelerator outputs due to coupling between input parameters and the dynamic evolution of the accelerating structure. Here, we use machine learning techniques to automate a 100 MeV-scale accelerator, which optimized its outputs by simultaneously varying up to six parameters including the spectral and spatial phase of the laser and the plasma density and length. Most notably, the model built by the algorithm enabled optimization of the laser evolution that might otherwise have been missed in single-variable scans. Subtle tuning of the laser pulse shape caused an 80% increase in electron beam charge, despite the pulse length changing by just 1%.

17 December 2019 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
BKBrendan Kettle
Brendan Kettle
EGE. Gerstmayr
E. Gerstmayr
MSM. J. V. Streeter
M. J. V. Streeter
FAF. Albert
F. Albert
RBR. A. Baggott
R. A. Baggott
SMS. P. D. Mangles
S. P. D. Mangles
Single-shot absorption measurements have been performed using the multi-keV x rays generated by a laser-wakefield accelerator. A 200 TW laser was used to drive a laser-wakefield accelerator in a mode which produced broadband electron beams with a maximum energy above 1 GeV and a broad divergence of ≈15  mrad FWHM. Betatron oscillations of these electrons generated 1.2±0.2×106  photons/eV in the 5 keV region, with a signal-to-noise ratio of approximately 300∶1. This was sufficient to allow high-resolution x-ray absorption near-edge structure measurements at the K edge of a titanium sample in a single shot. We demonstrate that this source is capable of single-shot, simultaneous measurements of both the electron and ion distributions in matter heated to eV temperatures by comparison with density functional theory simulations. The unique combination of a high-flux, large bandwidth, few femtosecond duration x-ray pulse synchronized to a high-power laser will enable key advances in the study of ultrafast energetic processes such as electron-ion equilibration.

13 January 2026 in Nature Communications
Verified
Journal Article
Open access
PDF file
ELEva E. Los
Eva E. Los
EGElias Gerstmayr
Elias Gerstmayr
CAChristopher Arran
Christopher Arran
MSMatthew J. V. Streeter
Matthew J. V. Streeter
CCCary Colgan
Cary Colgan
SMStuart P. D. Mangles
Stuart P. D. Mangles
Radiation reaction, the force experienced by an accelerated charge due to radiation emission, has long been the subject of extensive theoretical and experimental research. Experimental verification of a quantum, strong-field description of radiation reaction is fundamentally important, and has wide-ranging implications for astrophysics, laser-driven particle acceleration, next-generation particle colliders and inverse-Compton photon sources for medical and industrial applications. However, the difficulty of accessing regimes where strong field and quantum effects dominate inhibited previous efforts to observe quantum radiation reaction in charged particle dynamics with high significance. We report a high significance ( > 5σ) observation of strong-field radiation reaction on electron spectra where quantum effects are substantial. We obtain quantitative, strong evidence favouring the quantum-continuous and quantum-stochastic models over the classical model; the quantum models perform comparably. The lower electron energy losses predicted by the quantum models account for their improved performance. Model comparison was performed using a novel Bayesian framework, which has widespread utility for laser-particle collision experiments, including those utilising conventional accelerators, where some collision parameters cannot be measured directly.

24 January 2025 in Nature Communications
Verified
Journal Article
Open access
PDF file
MSM. J. V. Streeter
M. J. V. Streeter
GGGriffin Glenn
Griffin Glenn
SDS. DiIorio
S. DiIorio
FTFranziska Treffert
Franziska Treffert
BLB. Loughran
B. Loughran
CPC. A. J. Palmer
C. A. J. Palmer
Laser-plasma acceleration of protons offers a compact, ultra-fast alternative to conventional acceleration techniques, and is being widely pursued for potential applications in medicine, industry and fundamental science. Creating a stable, collimated beam of protons at high repetition rates presents a key challenge. Here, we demonstrate the generation of multi-MeV proton beams from a fast-replenishing ambient-temperature liquid sheet. The beam has an unprecedentedly low divergence of 1° (≤20 mrad), resulting from magnetic self-guiding of the proton beam during propagation through a low density vapour. The proton beams, generated at a repetition rate of 5 Hz using only 190 mJ of laser energy, exhibit a hundred-fold increase in flux compared to beams from a solid target. Coupled with the high shot-to-shot stability of this source, this represents a crucial step towards applications.

15 June 2023 in High Power Laser Science and Engineering
Verified
Journal Article
Open access
PDF file
SFScott Feister
Scott Feister
KCKevin Cassou
Kevin Cassou
SDStephen Dann
Stephen Dann
ADAndreas Döpp
Andreas Döpp
PGPhilippe Gauron
Philippe Gauron
CPCharlotte A. J. Palmer
Charlotte A. J. Palmer
The next generation of high-power lasers enables repetition of experiments at orders of magnitude higher frequency than what was possible using the prior generation. Facilities requiring human intervention between laser repetitions need to adapt in order to keep pace with the new laser technology. A distributed networked control system can enable laboratory-wide automation and feedback control loops. These higher-repetition-rate experiments will create enormous quantities of data. A consistent approach to managing data can increase data accessibility, reduce repetitive data-software development and mitigate poorly organized metadata. An opportunity arises to share knowledge of improvements to control and data infrastructure currently being undertaken. We compare platforms and approaches to state-of-the-art control systems and data management at high-power laser facilities, and we illustrate these topics with case studies from our community.

31 October 2022 in Physical Review Accelerators and Beams
Verified
Journal Article
Open access
PDF file
MSM. J. V. Streeter
M. J. V. Streeter
YMY. Ma
Y. Ma
BKBrendan Kettle
Brendan Kettle
SDS. J. D. Dann
S. J. D. Dann
EGE. Gerstmayr
E. Gerstmayr
ATA. G. R. Thomas
A. G. R. Thomas
We report on experimental measurements of energy transfer efficiencies in a GeV-class laser wakefield accelerator. Both the transfer of energy from the laser to the plasma wakefield and from the plasma to the accelerated electron beam was diagnosed by simultaneous measurement of the deceleration of laser photons and the acceleration of electrons as a function of plasma length. The extraction efficiency, which we define as the ratio of the energy gained by the electron beam to the energy lost by the self-guided laser mode, was maximized at 19±3% by tuning the plasma density and length. The additional information provided by the octave-spanning laser spectrum measurement allows for independent optimization of the plasma efficiency terms, which is required for the key goal of improving the overall efficiency of laser wakefield accelerators.