Huanyu Zhou

Huanyu Zhou

Auto-generated profile, based on publicly available information

Huanyu Zhou

Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HZHuanyu Zhou
Huanyu Zhou
YZYi Zhang
Yi Zhang
JLJin Li
Jin Li
YXYan Xuan
Yan Xuan
RZRongtong Zhu
Rongtong Zhu
ZZZhuangsheng Zhu
Zhuangsheng Zhu
The deterioration of spin coherence has been a significant challenge in the field of quantum magnetic measurements based on optically pumped atomic magnetometers (OPAMs). However, measurement and evaluation methods for specific relaxation components of OPAMs under working conditions remain lacking, which impedes further improvement in OPAM performance. To address this, we propose a methodology for quantifying the relaxation components of an OPAM under realistic operating conditions. Using this method, we confirm the existence of an anomalous relaxation mechanism induced by radio frequency (RF) magnetic fields and develop an empirical expression to describe its behavior. The results experimentally demonstrate that, in addition to the well-known spin-exchange relaxation, the dominant contributions to spin relaxation arise from optical pumping and RF magnetic fields. This work paves the way for sensitivity enhancement in quantum magnetometry and refines the theoretical understanding of relaxation mechanisms in OPAMs.

30 January 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
RZRongtong Zhu
Rongtong Zhu
JLJianli Li
Jianli Li
SSShuo Sun
Shuo Sun
HZHuanyu Zhou
Huanyu Zhou
YZYi Zhang
Yi Zhang
JLJin Li
Jin Li
Single-beam optically pumped atomic magnetometers (OPAMs) represent promising candidates for applications in geomagnetic field monitoring, biomedicine, and various other precision sensing domains owing to their exceptional sensitivity, high measurement accuracy, and cost-effectiveness. However, in orientation-based OPAMs utilizing circularly polarized light (CPL) pumping, the off-resonant light introduces light shift. The light shift acts as an additional magnetic field, reducing the measurement accuracy of OPAMs. Moreover, the dependence of the light shift on light intensity and frequency facilitates the conversion of light noise into magnetic noise, thereby degrading the sensitivity of OPAMs. In this study, we propose an optical pumping scheme based on space division multiplexing light (SDML) to suppress the light shift in OPAM. The approach employs two orthogonally polarized linearly polarized beams with a controlled phase difference to generate a spatially periodic distribution of left- and right-handed CPL. Optical pumping with the SDML induces oppositely directed light shifts in distinct spatial regions that effectively cancel each other. Finally, it is verified by experiments that the light shift is greatly suppressed based on SDML. Under detuned SDML pumping, both the light shift and light intensity noise are suppressed by over 50%, while maintaining a sensitivity comparable to that achieved with conventional CPL pumping. The proposed method demonstrates significant potential for magnetometers in light-noise-prone environments, and it can be generalized to other orientation-based magnetometers that rely on CPL pumping.