Clayon B. Hamilton

Clayon B. Hamilton

Auto-generated profile, based on publicly available information

Clayon B. Hamilton

Department of Physical Therapy, University of British Columbia, Vancouver, BC, Canada

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 August 2018 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
LFLynne M Feehan
Lynne M Feehan
JGJasmina Geldman
Jasmina Geldman
ESEric C Sayre
Eric C Sayre
CPChance Park
Chance Park
AEAllison M Ezzat
Allison M Ezzat
LLLinda C Li
Linda C Li
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Wearable Fitbit activity trackers are increasingly being used as outcome measurement tools in research and to inform healthcare decisions. However, the accuracy of these devices has not been systematically evaluated. Objective: To quantify Fitbit device measurement accuracy in controlled and free-living settings. Methods: Electronic searches using PubMed, Embase, CINAHL and SportsDiscus databases with a supplementary Google Scholar search. Original research published in English comparing Fitbit device measurements to a gold- or research-standard criterion in adults living with any health, disease or functional status. Risk of bias was assessed using a modified validation subscale in the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN). We identified and synthesized percent measurement error estimates for Fitbit measures of steps, energy expenditure (EE), sleep, distance and time in activity. Results: 67 studies met the inclusion criteria, with 57 incorporated in the quantitative syntheses. Respectively, 40, 21, 8, 6 and 2 studies included measures of steps, EE, time in activity, sleep and distance. Fitbit devices demonstrated acceptable accuracy in controlled settings (Mean % error: +/-3%) for measures of steps taken at normal, jogging and very slow walking speeds when worn on the torso, wrist and ankle respectively, and acceptable accuracy for measures of EE at rest and during very slow walking and for distance measures at normal walking speeds when worn on the wrist. Notable inaccuracies in controlled settings were underestimations of steps during household or sporting activities (Mean: -35.4%; SD: 20.5%) or when using a walking aid (Mean: -20.9%; SD: 22.4%), and underestimations of EE during inclined ambulation (Mean: -18.7%; SD: 22.2%) and overestimations of EE for walking on flat surfaces (Mean: 16.7%; SD: 31.4%). In free-living settings, Fitbit demonstrated acceptable relative accuracy (Mean % error: +/-10%) compared to a research-standard criterion for measures of daily steps when worn on the torso, as well as measures of time in bed and total EE over 15 days. Notable relative inaccuracies in free-living settings were mean error overestimations varying from 30% to 600% for time spent in light through vigorous activity and underestimation of daily steps in mobility-limited older adults (Mean: -24.3%; SD: 9.0%). Conclusions: Other than measures of steps during typical walking activities and EE at rest and across a number of days, the Fitbit activity trackers reviewed showed limited measurement accuracy in both controlled and free-living settings. Given the current limitations of Fitbit’s measurement accuracy, discretion should be exercised when using these devices as an outcome measurement tool in research or to inform healthcare decisions. Clinical Trial: N/A

6 October 2017 in Health Expectations
Verified
Journal Article
Open access
CHClayon B. Hamilton
Clayon B. Hamilton
AHAlison M. Hoens
Alison M. Hoens
CBCatherine L. Backman
Catherine L. Backman
AMAnnette M. McKinnon
Annette M. McKinnon
SMShanon McQuitty
Shanon McQuitty
LLLinda C Li
Linda C Li
Background: Patient engagement in research (PEIR) is promoted to improve the relevance and quality of health research, but has little conceptualization derived from empirical data.Objective: To address this issue, we sought to develop an empirically based conceptual framework for meaningful PEIR founded on a patient perspective.Methods: We conducted a qualitative secondary analysis of in‐depth interviews with 18 patient research partners from a research centre‐affiliated patient advisory board. Data analysis involved three phases: identifying the themes, developing a framework and confirming the framework. We coded and organized the data, and abstracted, illustrated, described and explored the emergent themes using thematic analysis. Directed content analysis was conducted to derive concepts from 18 publications related to PEIR to supplement, confirm or refute, and extend the emergent conceptual framework. The framework was reviewed by four patient research partners on our research team.Results: Participants’ experiences of working with researchers were generally positive. Eight themes emerged: procedural requirements, convenience, contributions, support, team interaction, research environment, feel valued and benefits. These themes were interconnected and formed a conceptual framework to explain the phenomenon of meaningful PEIR from a patient perspective. This framework, the PEIR Framework, was endorsed by the patient research partners on our team.Conclusions: The PEIR Framework provides guidance on aspects of PEIR to address for meaningful PEIR. It could be particularly useful when patient‐researcher partnerships are led by researchers with little experience of engaging patients in research.

1 November 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CHClayon B Hamilton
Clayon B Hamilton
AHAlison M Hoens
Alison M Hoens
SMShanon McQuitty
Shanon McQuitty
AMAnnette M McKinnon
Annette M McKinnon
KEKelly English
Kelly English
LLLinda C Li
Linda C Li
To develop and examine the content and face validity of the Patient Engagement In Research Scale (PEIRS) for assessing the quality of patient engagement in research projects from a patient partner perspective. Our team of researchers and patient partners conducted a mixed qualitative and quantitative study in three phases. Participants were English-speaking adult patients (including informal caregivers, family members, and friends) with varying experiences as partners in research projects in Canada. 1) Questionnaire items were generated following thematic analysis of in-depth interviews and published literature. 2) A three-round e-Delphi survey process via email correspondence was undertaken to refine and select the items for a provisional PEIRS. 3) Two rounds of cognitive interviewing elicited participants’ understanding and opinions of each item and the structure of the PEIRS. One hundred and twenty items were generated from 18 interviews and organized across eight themes of meaningful engagement of patients in health research to form an initial questionnaire. The e-Delphi survey and cognitive interviewing each included 12 participants with a range of self-reported diseases, health-related conditions, and use of healthcare services. The e-Delphi survey yielded a 43-item provisional PEIRS. The PEIRS was then reduced to 37 items organized across seven themes after 1) refinement of problems in its instructions and items, and 2) the combining of two themes into one. We developed a 37-item self-reported questionnaire that has demonstrated preliminary content and face validity for assessing the quality of patient engagement in research.

4 March 2018 in Journal of Health Services Research & Policy
Verified
Journal Article
Open access
ABAgnes Black
Agnes Black
KSKimberly Strain
Kimberly Strain
CWChristine Wallsworth
Christine Wallsworth
SCSara-Grey Charlton
Sara-Grey Charlton
WCWilma Chang
Wilma Chang
CHClayon Hamilton
Clayon Hamilton
Objective: There is growing emphasis on health care organizations to ensure that lay people are meaningfully engaged as partners on research teams. Our aim was to explore the perspectives of patients, family members and informal caregivers who have been involved on health care research teams in Canada and elicit their recommendations for meaningful engagement. Methods: We conducted a qualitative study guided by thematic analysis of transcripts of focus groups and interviews of 19 experienced patient research partners in Canada. Results: We identified four main themes: research environment, expectations, support and value, which highlight participants’ combined perspectives on important factors to ensure their engagement in research is meaningful. Conclusions: Our findings add to the evolving evidence base on the perspectives of lay people involved in health care research and their recommendations for research leaders on meaningful engagement. Our study suggests that research leaders should provide a welcoming research environment, outline appropriate expectations for patient research partners on research teams, support patient research partners’ engagement in projects and recognize the value patient research partners bring to health research.

1 July 2014 in Physiotherapy Canada
Verified
Journal Article
Closed access
BCBert M. Chesworth
Bert M. Chesworth
CHClayon B. Hamilton
Clayon B. Hamilton
DWDavid M. Walton
David M. Walton
MBMelissa Benoit
Melissa Benoit
TBTracy A. Blake
Tracy A. Blake
DYDarryl Yardley
Darryl Yardley
Purpose: To examine the reliability, validity, and sensitivity to change of the 20-item version and the Rasch-refined 15-item version of the Upper Extremity Functional Index (UEFI-20 and UEFI-15, respectively) and to determine the impact of arm dominance on the positive minimal clinically important difference (pMCID). Methods: Adults with upper-extremity (UE) dysfunction completed the UEFI-20, Upper Extremity Functional Scale (UEFS), Pain Limitation Scale, and Pain Intensity Scale at their initial physiotherapy assessment (Time 1); 24–48 hours later (Time 2); and 3 weeks into treatment or at discharge, whichever came first (Time 3). Demographics, including working status, were obtained at Time 1. Global ratings of change (GRC) were provided by the treating physiotherapist and patient at Time 3. The UEFI-15 was calculated from relevant items in the UEFI-20. The intra-class correlation coefficient (ICC) and minimal detectable change (MDC) quantified test–retest reliability (Time 1–Time 2). Cross-sectional convergent validity was determined by the association (Pearson's r) between Time 1 measures of function and pain. Known-groups validity was evaluated with a one-way ANOVA across three levels of working status. Longitudinal validity was determined by the association (Pearson's r) between function and pain change scores (Time 1–Time 3). Receiver operating characteristic (ROC) curves estimated the pMCID using Time 1–Time 3 change scores and average patient/therapist GRC. Results: Reliability for the UEFI-20 and UEFI-15 was the same (ICC=0.94 for both measures). MDC values were 9.4/80 for the UEFI-20 and 8.8/100 for the UEFI-15. Cross-sectional, known-groups, and longitudinal validity were confirmed for both UEFI measures. pMCID values were 8/80 for the UEFI-20 and 6.7/100 for the UEFI-15; pMCID was higher for people whose non-dominant arm was affected. Conclusions: Both UEFI measures show acceptable reliability and validity. Arm dominance affects pMCID. The UEFI-15 is recommended because it measures only one dimension: UE function.

17 March 2021 in Health Expectations
Verified
Journal Article
Open access
PDF file
CHClayon B. Hamilton
Clayon B. Hamilton
AHAlison M. Hoens
Alison M. Hoens
AMAnnette M. McKinnon
Annette M. McKinnon
SMShanon McQuitty
Shanon McQuitty
KEKelly English
Kelly English
LLLinda C Li
Linda C Li
Objective: To shorten the Patient Engagement In Research Scale (PEIRS) to its most essential items and evaluate its measurement properties for assessing the degree of patients’ and family caregivers’ meaningful engagement as partners in research projects.Methods: A prospective cross‐sectional web‐based survey in Canada and the USA, and also paper‐based in Canada. Participants were patients or family caregivers who had engaged in research projects within the last 3 years, were ≥17 years old, and communicated in English. Extensive psychometric analyses were conducted.Results: 119 participants: 99 from Canada, 74 female, 51 aged 17‐35 years and 50 aged 36‐65 years, 60 had post‐secondary education, and 74 were Caucasian/white. The original 37‐item PEIRS was shortened to 22 items (PEIRS‐22), mainly because of low inter‐item correlations. PEIRS‐22 had a single dominant construct that accounted for 55% of explained variance. Analysis of PEIRS‐22 scores revealed the following: (1) acceptable floor and ceiling effects (<15%), (2) internal consistency (ordinal alpha = 0.96), (3) structural validity by fit to a Rasch measurement model, (4) construct validity by moderate correlations with the Public and Patient Engagement Evaluation Tool, (5) good test‐retest reliability (ICC2,1 = 0.86) and (6) interpretability demonstrated by significant differences among PEIRS‐22 scores across three levels of global meaningful engagement in research.Conclusions: The shortened PEIRS is valid and reliable for assessing the degree of meaningful patient and family caregiver engagement in research. It enables standardized assessment of engagement in research across various contexts.Patient or public contribution: A researcher‐initiated collaboration, patient partners contributed from study conception to manuscript write‐up.