Raphaël Blanc

Raphaël Blanc

Auto-generated profile, based on publicly available information

Raphaël Blanc

Department of Interventional Neuroradiology, Fondation Rothschild Hospital, Paris, France

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 October 2019 in Neurology
Verified
Journal Article
Closed access
PDF file
LMLucas Di Meglio
Lucas Di Meglio
JDJean-Philippe Desilles
Jean-Philippe Desilles
VOVéronique Ollivier
Véronique Ollivier
MNMialitiana Solo Nomenjanahary
Mialitiana Solo Nomenjanahary
SMSara Di Meglio
Sara Di Meglio
MMMikael Mazighi
Mikael Mazighi
Objectives Thrombi responsible for large vessel occlusion (LVO) in the setting of acute ischemic stroke (AIS) are characterized by a low recanalization rate after IV thrombolysis. To test whether AIS thrombi have inherent common features that limit their susceptibility to thrombolysis, we analyzed the composition and ultrastructural organization of AIS thrombi causing LVO. Methods A total of 199 endovascular thrombectomy-retrieved thrombi were analyzed by immunohistology and scanning electron microscopy (SEM) and subjected to ex vivo thrombolysis assay. The relationship between thrombus organization and thrombolysis resistance was further investigated in vitro using thrombus produced by recalcification of citrated whole blood. Results SEM and immunohistology analyses revealed that, although AIS thrombus composition and organization was highly heterogeneous, AIS thrombi shared a common remarkable structural feature in the form of an outer shell made of densely compacted thrombus components including fibrin, von Willebrand factor, and aggregated platelets. In vitro thrombosis experiments using human blood indicated that platelets were essential to the formation of the thrombus outer shell. Finally, in both AIS and in vitro thrombi, the thrombus outer shell showed a decreased susceptibility to tissue plasminogen activator–mediated thrombolysis as compared to the thrombus inner core. Interpretation Irrespective of their etiology and despite their heterogeneity, intracranial thrombi causing LVO have a core shell structure that influences their susceptibility to thrombolysis.

2 June 2016 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
BLB. Lapergue
B. Lapergue
RBR. Blanc
R. Blanc
PGP. Guedin
P. Guedin
JDJ.-P. Decroix
J.-P. Decroix
JLJ. Labreuche
J. Labreuche
MPM. Piotin
M. Piotin
BACKGROUND AND PURPOSE: Mechanical thrombectomy with stent retrievers is now the standard therapy for selected patients with ischemic stroke. The technique of A Direct Aspiration, First Pass Technique for the Endovascular Treatment of Stroke (ADAPT) appears promising with a high rate of recanalization. We compared ADAPT versus stent retrievers (the Solitaire device) for efficacy and safety as a front-line endovascular procedure. MATERIALS AND METHODS: We analyzed 243 consecutive patients with large intracranial artery occlusions of the anterior circulation, treated within 6 hours with mechanical thrombectomy by either ADAPT or the Solitaire stent. Th primary outcome was complete recanalization (modified TICI ≥ 2b); secondary outcomes included complication rates and procedural and clinical outcomes. RESULTS: From November 2012 to June 2014, 119 patients were treated with stent retriever (Solitaire FR) and 124 by using the ADAPT with Penumbra reperfusion catheters. The median baseline NIHSS score was the same for both groups (Solitaire, 17 [interquartile range, 11–21] versus ADAPT, 17 [interquartile range, 12–21]). Time from groin puncture to recanalization (Solitaire, 50 minutes [range, 25–80 minutes] versus ADAPT, 45 minutes [range, 27–70 minutes], P = .42) did not differ significantly. However, compared with the Solitaire group, patients treated with ADAPT achieved higher final recanalization rates (82.3% versus 68.9%; adjusted relative risk, 1.18; 95% CI, 1.02–1.37; P = .022), though differences in clinical outcomes between the cohorts were not significant. Use of an adjunctive device was more frequent in the ADAPT group (45.2% versus 13.5%, P < .0001). The rate of embolization in new territories or symptomatic hemorrhage did not differ significantly between the 2 groups. CONCLUSIONS: Front-line ADAPT achieved higher recanalization rates than the Solitaire device. Further randomized controlled trials are warranted to define the best strategy for mechanical thrombectomy.

30 July 2019 in Neurology
Verified
Journal Article
Closed access
PDF file
WBWilliam Boisseau
William Boisseau
JDJean-Philippe Desilles
Jean-Philippe Desilles
RFRobert Fahed
Robert Fahed
MKMaeva Kyheng
Maeva Kyheng
KZKevin Zuber
Kevin Zuber
RBRaphael Blanc
Raphael Blanc
Objective To identify early prognostic factors of poor clinical outcome in patients treated by endovascular therapy (EVT) with successful recanalization. Methods We reviewed our monocentric prospectively collected EVT database of patients with anterior circulation acute ischemic stroke (AIS) from January 2016 to April 2018 who had achieved successful recanalization (Thrombolysis in Cerebral Infarction score ≥ 2b) at the end of the procedure. A poor outcome was defined as a 3-month modified Rankin Scale score of ≥3. Results A total of 324 patients were included, among whom 186 (57.4%) had a poor outcome. Multivariate logistic regression indicated that age (per 10-year increase, odds ratio [OR] 1.34, 95% confidence interval [CI] 1.12–1.60), baseline NIH Stroke Scale score (per 1-unit increase, OR 1.09, 95% CI 1.04–1.15), initial infarct volume (per a log+1 increase, OR 1.34, 95% CI 1.05–1.67), blood glucose level (per a log+1 increase, OR 2.60, 95% CI 1.01–6.66), and neutrophil count (per 1,000-unit increase, OR 1.08, 95% CI 1.01–1.17) were all associated with poor clinical outcome. Conclusions In addition to baseline severe AIS criteria, high neutrophil count and high blood glucose, known from experimental studies to be associated with downstream microvascular thromboinflammation, are independently associated with poor outcome. These findings support a deleterious role of thromboinflammation in patient recovery despite successful recanalization.

12 June 2020 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Open access
PDF file
WBWilliam Boisseau
William Boisseau
SESimon Escalard
Simon Escalard
RFRobert Fahed
Robert Fahed
BLBertrand Lapergue
Bertrand Lapergue
SSStanislas Smajda
Stanislas Smajda
RBRaphaël Blanc
Raphaël Blanc
Mechanical thrombectomy is now the standard of care for acute ischemic stroke patients with large vessel occlusions, and can be performed with several devices and techniques. One of these techniques, direct aspiration (DA), consists of navigating a large-bore catheter up to the face of the clot and initiating forceful suction. This comprehensive review has three objectives: (1) to describe the direct aspiration technique; (2) to present the available evidence regarding predictive factors of DA success and performance compared with other techniques; and (3) to discuss the forthcoming improvements in distal aspiration.

1 June 2017 in Stroke
Verified
Journal Article
Closed access
PDF file
RBRaphaël Blanc
Raphaël Blanc
HRHocine Redjem
Hocine Redjem
GCGabriele Ciccio
Gabriele Ciccio
SSStanislas Smajda
Stanislas Smajda
JDJean-Philippe Desilles
Jean-Philippe Desilles
MPMichel Piotin
Michel Piotin
Background and Purpose—: A direct aspiration first pass technique (ADAPT) has been reported to be fast, safe, and effective for the treatment of acute ischemic stroke. The aim of this study is to determine the preoperative factors that affect success of the aspiration component of the technique in ischemic stroke patients with large vessel occlusion in the anterior circulation. Methods—: We enrolled all 347 consecutive patients with anterior circulation acute ischemic stroke admitted for mechanical thrombectomy at our institution from August 2013 to October 2015 and treated by ADAPT for the endovascular treatment of stroke. Baseline and procedural characteristics, modified thrombolysis in cerebral infarction scores, and 3-month modified Rankin Scale were captured and analyzed. Results—: Among the 347 patients (occlusion sites: middle cerebral artery=200, 58%; internal carotid artery Siphon=89, 25%; Tandem=58, 17%), aspiration component led to successful reperfusion (modified thrombolysis in cerebral infarction 2b/3 scores) in 55.6% (193/347 patients), stent retrievers were required in 40%, and a total successful final reperfusion rate of 83% (288/347) was achieved. Overall, procedural complications occurred in 13.3% of patients (48/347). Modified Rankin Scale score of 0 to 2 at 90 days was reported in 45% (144/323). Only 2 factors positively influenced the success of the aspiration component: an isolated middle cerebral artery occlusion ( P <0.001) and a shorter time from stroke onset to clot contact ( P =0.018). Conclusions—: In this large retrospective study, ADAPT was shown to be safe and effective for anterior circulation acute ischemic stroke with a final successful reperfusion achieved in 83%. The site of arterial occlusion and delay of the procedure were predictors for reperfusion. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT02523261, NCT02678169, and NCT02466893.

29 March 2018 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
EKE. Kalsoum
E. Kalsoum
ANA. Chabernaud Negrier
A. Chabernaud Negrier
TTT. Tuilier
T. Tuilier
ABA. Benaïssa
A. Benaïssa
RBR. Blanc
R. Blanc
JHJ. Hodel
J. Hodel
SUMMARY: Our aim was to compare the detectability of aneurysmal wall enhancement in unruptured intracranial aneurysms between conventional and motion-sensitized driven equilibrium–prepared postcontrast 3D T1-weighted TSE sequences (sampling perfection with applicationoptimized contrasts by using different flip angle evolution, SPACE). Twenty-two patients with 30 unruptured intracranial aneurysms were scanned at 3T. Aneurysmal wall enhancement was more significantly detected using conventional compared with motion-sensitized driven equilibrium–prepared SPACE sequences (10/30 versus 2/30, P < .0001). Contrast-to-noise ratio measurements did not differ between conventional and motion-sensitized driven equilibrium–prepared sequences (P = .51). Flowing blood can mimic aneurysmal wall enhancement using conventional SPACE sequences with potential implications for patient care.