Ryo Takagi

Ryo Takagi

Auto-generated profile, based on publicly available information

Ryo Takagi

Medical Devices Research Group, Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba 305-8564, Japan

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2010 in Japanese Journal of Applied Physics
Verified
Journal Article
Closed access
RTRyo Takagi
Ryo Takagi
SYShin Yoshizawa
Shin Yoshizawa
SUShin-Ichiro Umemura
Shin-Ichiro Umemura
There are reports that ultrasonically induced cavitation bubbles locally enhance tissue heating in high intensity focused ultrasound (HIFU) treatment. In this study, a high-intensity burst (named “a triggering pulse”) above the cavitation threshold was used to trigger cavitation. Immediately after that, CW ultrasound (named “heating waves”), at an intensity level and duration typical for conventional HIFU ablation was irradiated. Before the ablating sonication, it is necessary to determine the optimum intensity and duration of the triggering pulse. Immediately after a test triggering pulse, low-intensity CW ultrasound (named “a sustaining pulse”) was irradiated for a short duration of time, and we detected the cavitation noises (subharmonics and higher harmonics) generated in the focus spot. The relationship between the 1/2 subharmonic signal amplitude and the coagulation volume after the ablating sonication was investigated. The result of this experiment suggests that we can optimize the triggering pulse by detecting the 1/2 subharmonic signal amplitude.

16 June 2014 in Japanese Journal of Applied Physics
Verified
Journal Article
Closed access
HSHiroshi Sasaki
Hiroshi Sasaki
JYJun Yasuda
Jun Yasuda
RTRyo Takagi
Ryo Takagi
TMTakuya Miyashita
Takuya Miyashita
KGKota Goto
Kota Goto
SUShin-Ichiro Umemura
Shin-Ichiro Umemura

1 July 2013 in Japanese Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
SUShin-Ichiro Umemura
Shin-Ichiro Umemura
SYShin Yoshizawa
Shin Yoshizawa
RTRyo Takagi
Ryo Takagi
YIYuta Inaba
Yuta Inaba
JYJun Yasuda
Jun Yasuda
Microbubbles, whether introduced from outside the body or ultrasonically generated in situ, are known to significantly enhance the biological effects of ultrasound, including the mechanical, thermal, and sonochemical effects. Phase-change nanodroplets, which selectively accumulate in tumor tissue and whose phase changes to microbubbles can be induced by ultrasonic stimulation, have been proposed for high-intensity focused ultrasound (HIFU) tumor treatment with enhanced selectivity and efficiency. In this paper, a purely acoustic approach to generate microbubble clouds in the tissue to be treated is proposed. Short pulses of focused ultrasound with extremely high intensity, named trigger pulses, are used for exposure. They are immediately followed by focused ultrasound for heating with an intensity similar to or less than that of normal HIFU treatment. The localized generation of microbubble clouds by the trigger pulses is observed in a polyarylamide gel by a high-speed camera, and the effectiveness of the generated clouds in accelerating ultrasonically induced thermal coagulation is confirmed in excised chicken breast tissue. The use of second-harmonic superimposed waves as the trigger pulses is also proposed. The highly reproducible initiation of cavitation by waves with the negative peak pressure emphasized and the efficient expansion of the generated microbubble clouds by waves with the positive peak pressure emphasized are also observed by a high-speed camera in partially degassed water.

16 March 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SYShin Yoshizawa
Shin Yoshizawa
RTRyo Takagi
Ryo Takagi
SUShin-Ichiro Umemura
Shin-Ichiro Umemura
A target tissue can be thermally coagulated in high-intensity focused ultrasound (HIFU) treatment noninvasively. HIFU thermal treatments have been clinically applied to various solid tumors. One of the problems in HIFU treatments is a long treatment time. Acoustically driven microbubbles can accelerate the ultrasonic heating, resulting in the significant reduction of the treatment time. In this paper, a method named “trigger HIFU exposure” which employs cavitation microbubbles is introduced and its results are reviewed. A trigger HIFU sequence consists of high-intensity short pulses followed by moderate-intensity long bursts. Cavitation bubbles induced in a multiple focal regions by rapidly scanning the focus of high-intensity pulses enhanced the temperature increase significantly and produced a large coagulation region with high efficiency.

16 June 2014 in Japanese Journal of Applied Physics
Verified
Journal Article
Closed access
SSShoya Sasaki
Shoya Sasaki
RTRyo Takagi
Ryo Takagi
KMKeiko Matsuura
Keiko Matsuura
SYShin Yoshizawa
Shin Yoshizawa
SUShin-Ichiro Umemura
Shin-Ichiro Umemura
High-intensity focused ultrasound (HIFU) is a type of therapeutic treatment in which ultrasound is focused to a target tissue such as cancer to be thermally coagulated. To enhance the safety and accuracy of HIFU treatment, a noninvasive method of monitoring the thermal lesion formation is important. A potential method for this purpose is ultrasound imaging. In this study, high-speed imaging by parallel beamforming was performed using ultrasound RF signals acquired during HIFU exposure, and the distribution of the cross-correlation coefficient between RF frames was calculated to estimate the tissue coagulation. Using high-speed imaging, HIFU can be irradiated quasi-continuously. The result shows that the decorrelation was observed at and around the focal spot of HIFU exposure. The decorrelation was induced by the change in RF signals owing to tissue coagulation, which was confirmed by the fact that the emergence and increase in the number of decorrelated pixels at and around the focal spot corresponded to the start and progress of tissue coagulation.

14 April 2016 in Journal of Therapeutic Ultrasound
Verified
Journal Article
Open access
PDF file
SYShin Yoshizawa
Shin Yoshizawa
KMKeiko Matsuura
Keiko Matsuura
RTRyo Takagi
Ryo Takagi
MYMariko Yamamoto
Mariko Yamamoto
SUShin-Ichiro Umemura
Shin-Ichiro Umemura
A noninvasive technique to monitor thermal lesion formation is necessary to ensure the accuracy and safety of high-intensity focused ultrasound (HIFU) treatment. The purpose of this study is to ultrasonically detect the tissue change due to thermal coagulation in the HIFU treatment enhanced by cavitation microbubbles. An ultrasound imaging probe transmitted plane waves at a center frequency of 4.5 MHz. Ultrasonic radio-frequency (RF) echo signals during HIFU exposure at a frequency of 1.2 MHz were acquired. Cross-correlation coefficients were calculated between in-phase and quadrature (IQ) data of two B-mode images with an interval time of 50 and 500 ms for the estimation of the region of cavitation and coagulation, respectively. Pathological examination of the coagulated tissue was also performed to compare with the corresponding ultrasonically detected coagulation region. The distribution of minimum hold cross-correlation coefficient between two sets of IQ data with 50-ms intervals was compared with a pulse inversion (PI) image. The regions with low cross-correlation coefficients approximately corresponded to those with high brightness in the PI image. The regions with low cross-correlation coefficients in 500-ms intervals showed a good agreement with those with significant change in histology. The results show that the regions of coagulation and cavitation could be ultrasonically detected as those with low cross-correlation coefficients between RF frames with certain intervals. This method will contribute to improve the safety and accuracy of the HIFU treatment enhanced by cavitation microbubbles.