8 June 2012 in IEEE Transactions on Smart Grid
This paper proposes a hierarchical active power management strategy for a medium voltage (MV) islanded microgrid including a multihybrid power conversion system (MHPCS). To guarantee excellent power management, a modular power conversion system is realized by parallel connection of small MHPCS units. The hybrid system includes fuel cells (FC) as main and supercapacitors (SC) as complementary power sources. The SC energy storage compensates the slow transient response of the FC stack and supports the FC to meet the grid power demand. The proposed control strategy of the MHPCS comprises three control loops; dc-link voltage controller, power management controller, and load current sharing controller. Each distributed generation (DG) unit uses an adaptive proportional resonance (PR) controller for regulating the load voltage, and a droop control strategy for average power sharing among the DG units. The performance of the proposed control strategy is verified by using digital time-domain simulation studies in the PSCAD/EMTDC software environment.
1 February 2013 in Electric Power Systems Research
12 January 2016 in IEEE Transactions on Industrial Electronics
This paper presents a resilient framework for fault-tolerant operation in modular multilevel converters (MMCs) to facilitate normal operation under internal and external fault conditions. This framework is realized by designing and implementing a supervisory algorithm and a postfault restoration scheme. The supervisory algorithm includes monitoring and decision-making units to detect and identify faults by analyzing the circulating current and submodule capacitor voltages in a very short time. The postfault restoration scheme is proposed to immediately replace the faulty submodule with the redundant healthy one. The restoration is achieved by virtue of a multilevel modular capacitor-clamped dc/dc converter (MMCCC), which is redundantly aggregated to each arm of the MMC. This design effectively guarantees smooth mode transition and handles the failure of multiple submodules in a short time interval. In addition, a modified modulation scheme is presented to ensure submodule capacitor voltage balancing of the MMC without implementing any additional hardware. Fast fault identification, a fully modular structure, and robust postfault restoration are the main features of the proposed framework. Digital time-domain simulation studies are conducted on a 21-level MMC to confirm the effectiveness and resilience of the proposed fault-tolerant framework during internal and external faults. Furthermore, the proposed framework is implemented in the FPGA-based RT-LAB real-time simulator platform to validate its resilience in a hardware-in-the-loop setup.
1 September 2013 in IEEE Transactions on Energy Conversion
This paper presents a control strategy for an islanded medium voltage microgrid to coordinate hybrid power source (HPS) units and to control interfaced multilevel inverters under unbalanced and nonlinear load conditions. The proposed HPS systems are connected to the loads through a cascaded H-bridge (CHB) multilevel inverter. The CHB multilevel inverters increase the output voltage level and enhance power quality. The HPS employs fuel cell (FC) and photovoltaic sources as the main and supercapacitors as the complementary power sources. Fast transient response, high performance, high power density, and low FC fuel consumption are the main advantages of the proposed HPS system. The proposed control strategy consists of a power management unit for the HPS system and a voltage controller for the CHB multilevel inverter. Each distributed generation unit employs a multiproportional resonant controller to regulate the buses voltages even when the loads are unbalanced and/or nonlinear. Digital time-domain simulation studies are carried out in the PSCAD/EMTDC environment to verify the performance of the overall proposed control system.
20 May 2015 in IEEE Transactions on Industrial Electronics
This paper presents an effective control scheme in dc microgrids to precisely share the load current oscillatory and dc components among distributed generation (DG) units. The proposed control strategy includes current and voltage control blocks. The current control block consists of oscillatory and dc current-sharing units. The main idea of the proposed method is to share the load current oscillatory and dc components among the DG units based on their rated power, by assigning appropriate output impedance values and droop coefficients to each DG unit. The voltage control block is a multiloop voltage control unit employed to control the microgrid voltage. The detailed model of the proposed control architecture is established, and the system dynamics is analyzed. Since the synthesis of a local controller uses only information of the corresponding DG unit, the design procedure is totally decentralized. The performance and dynamic response of the proposed control scheme are verified through extensive simulation studies and experimental results.
24 July 2015 in IEEE Journal of Emerging and Selected Topics in Power Electronics
This paper presents a new sensorless capacitor voltage balancing strategy for modular multilevel converters (MMCs) to effectively balance the submodule capacitor voltages in a wide range of switching frequencies. The proposed strategy is realized via a balancing unit equipped with a hierarchical permutation cyclic coding (PCC) method to evenly distribute the switching gate signals among the submodules of each arm within a permutation time. The proposed strategy balances the submodule capacitor voltages to track their reference values with low voltage ripple in a wide range of switching frequencies. It remarkably enhances the converter system reliability, especially for a large number of submodules, because the need to measure the submodule capacitor voltages in each arm is eliminated. The proposed hierarchical PCC algorithm is decoupled from other standard control loops in an MMC. Digital time-domain simulation studies are conducted on a 21-level MMC to confirm the effectiveness of the proposed algorithm in high and low switching frequencies under balanced and unbalanced load conditions. In addition, the proposed method is implemented in the FPGA-based RT-LAB real-time simulator platform to validate its performance in a hardware-in-the-loop setup.