Kenji Tomita

Kenji Tomita

Auto-generated profile, based on publicly available information

Kenji Tomita

Technology Advancement Center, Graduate School of Agricultural and Life Sciences, The University of Tokyo, Tokyo, Japan

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 December 1994 in Physical Review D
Verified
Journal Article
Closed access
PDF file
KTKenji Tomita
Kenji Tomita
NDNathalie Deruelle
Nathalie Deruelle
Nonlinear behaviors of cosmological inhomogeneities are studied in the anti-Newtonian or long-wavelength approximation. They consist of a standard fluid and inflationary matter. The latter is an inflationary fluid or a scalar field. After the initially dominant local anisotropy has decreased, they become quasiisotropic. If the density of the standard fluid is dominant at this stage, the inhomogeneities grow with time, but, as the density of the inflationary matter increases, it is shown that the growth is gradually prevented and finally they decay. After the inflation they again grow due to the irregular spatial curvature. The generality of the solutions is also discussed.

15 September 1997 in Physical Review D
Verified
Journal Article
Closed access
PDF file
KTKenji Tomita
Kenji Tomita
To clarify the evolution of inhomogeneous substructures in large-scale structures such as voids, we study the perturbations in a spherically symmetric inhomogeneous model with the self-similar region outside the inner low-density homogeneous region, first based on the Gerlach-Sengupta general-relativistic formulation for perturbations in spherically symmetric inhomogeneous models. Owing to self-similarity, the analysis for all kinds of perturbations at the early stage is simplified in a similar way to homogeneous models. Next we take the approximate treatment due to the local homogeneous model with the average density parameter which is considered at each point, in order to study the behavior of perturbations on small scales. It is found that the growth rate of density perturbations in the outside self-similar region can be larger by about 30−20% (for z=2−3) than that in the corresponding ordinary low-density homogeneous model.

1 April 1996 in The Astrophysical Journal
Verified
Journal Article
Closed access
KTKenji Tomita
Kenji Tomita

5 May 2017 in Progress of Theoretical and Experimental Physics
Verified
Journal Article
Open access
PDF file
KTKenji Tomita
Kenji Tomita
It is shown that the serious problem in the cosmological tension between the direct measurements of the Hubble constant at present and the constant derived from the Planck measurements of the CMB anisotropies can be solved by considering the renormalized model parameters. They are deduced by taking the spatial average of second-order perturbations in the flat |$\Lambda$|-CDM model, which includes random adiabatic fluctuations.

1 January 1998 in Progress of Theoretical Physics
Verified
Journal Article
Open access
KTK. Tomita
K. Tomita

5 April 2016 in SAE International Journal of Advances and Current Practices in Mobility
Verified
Conference Paper
Closed access
HNHideaki Nagano
Hideaki Nagano
KTKenji Tomita
Kenji Tomita
YTYasuhiro Tanoue
Yasuhiro Tanoue
YKYuji Kobayashi
Yuji Kobayashi
IKItsuhei Kohri
Itsuhei Kohri
SKShinsuke Kato
Shinsuke Kato
In the winter, windshield glass fogging must be prevented through the intake of outdoor air into a vehicle. However, the corresponding energy loss via the ventilation system cannot be ignored. In the present study, the defogging pattern on the windshield is evaluated and the water vapor transportation in the flow field in the vehicle is analyzed in order to investigate the ventilation load by means of a numerical simulation. Some examined cases involve new outlet positions. Additionally, a new, energy-saving air supply method for defogging, with so-called “double-layer ventilator”, is proposed. In this method, one air jet layer is obtained via a conventional defogging opening in the vicinity of the windshield, supplying an outdoor air intake. The other jet consists of recirculated air that covers the outdoor air, preventing it from mixing with the surrounding air. The calculation results indicate that the exhaust opening location, from which the internal vehicle air is obtained for recirculation, affects the cabin flow field, the windshield fogging pattern and the ventilation load. The water vapor generated from human occupants did not spread well and that is why there was the humidity gradient in the vehicle. This means that the flow field must be considered in order to achieve efficient defogging, that is done by emitting the water vapor immediately. The double-layer method exhibits the same level of defogging performance as single-layer techniques, even with half the airflow velocity. The energy load can be reduced by approximately 5 % using the appropriate conditions.