Tanja Alderliesten

Tanja Alderliesten

Auto-generated profile, based on publicly available information

Tanja Alderliesten

Leiden University Medical Center

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Evolutionary Computation
Verified
Journal Article
Closed access
MVM. Virgolin
M. Virgolin
TAT. Alderliesten
T. Alderliesten
CWC. Witteveen
C. Witteveen
PBP. A. N. Bosman
P. A. N. Bosman
The Gene-pool Optimal Mixing Evolutionary Algorithm (GOMEA) is a model-based EA framework that has been shown to perform well in several domains, including Genetic Programming (GP). Differently from traditional EAs where variation acts blindly, GOMEA learns a model of interdependencies within the genotype, that is, the linkage, to estimate what patterns to propagate. In this article, we study the role of Linkage Learning (LL) performed by GOMEA in Symbolic Regression (SR). We show that the non-uniformity in the distribution of the genotype in GP populations negatively biases LL, and propose a method to correct for this. We also propose approaches to improve LL when ephemeral random constants are used. Furthermore, we adapt a scheme of interleaving runs to alleviate the burden of tuning the population size, a crucial parameter for LL, to SR. We run experiments on 10 real-world datasets, enforcing a strict limitation on solution size, to enable interpretability. We find that the new LL method outperforms the standard one, and that GOMEA outperforms both traditional and semantic GP. We also find that the small solutions evolved by GOMEA are competitive with tuned decision trees, making GOMEA a promising new approach to SR.

4 August 2022 in Cancers
Verified
Journal Article
Open access
PDF file
KBKelly L A van Bindsbergen
Kelly L A van Bindsbergen
HHHinke van der Hoek
Hinke van der Hoek
MGMarloes van Gorp
Marloes van Gorp
MLMike Ligthart
Mike Ligthart
Koen HindriksKoen Hindriks
Koen Hindriks
RLRaphaële R. L. van Litsenburg
Raphaële R. L. van Litsenburg
Objectives: Children with cancer often experience sleep problems, which are associated with many negative physical and psychological health outcomes, as well as with a lower quality of life. Therefore, interventions are strongly required to improve sleep in this population. We evaluated interactive education with respect to sleep hygiene with a social robot at a pediatric oncology outpatient clinic regarding the feasibility, experiences, and preliminary effectiveness. Methods: Researchers approached children (8 to 12 years old) who were receiving anticancer treatment and who were visiting the outpatient clinic with their parents during the two-week study period. The researchers completed observation forms regarding feasibility, and parents completed the Children’s Sleep Hygiene Scale before and two weeks after the educational regimen. The experiences of children and parents were evaluated in semi-structured interviews. We analyzed open answers by labeling each answer with a topic reflecting the content and collapsed these topics into categories. We used descriptive statistics to describe the feasibility and experiences, and a dependent-samples t-test to evaluate the preliminary effectiveness. Results: Twenty-eight families participated (58% response rate) and all interactions with the robot were completed. The children and parents reported that they learned something new (75% and 50%, respectively), that they wanted to learn from the robot more often (83% and 75%, respectively), and that they applied the sleeping tips from the robot afterwards at home (54%). Regarding the preliminary effectiveness, children showed a statistically significant improvement in their sleep hygiene (p = 0.047, d = 0.39). Conclusions: Providing an educational regimen on sleep hygiene in a novel, interactive way by using a social robot at the outpatient clinic seemed feasible, and the children and parents mostly exhibited positive reactions. We found preliminary evidence that the sleep hygiene of children with cancer improved.

27 March 2023 in Cancers
Verified
Journal Article
Open access
PDF file
BTBuket Kinaci- Tas
Buket Kinaci- Tas
TATanja Alderliesten
Tanja Alderliesten
FVFrank D. Verbraak
Frank D. Verbraak
CRCoen Rasch
Coen Rasch
Background: Patients with brain, head, and neck tumors experience a decline in their quality of life due to radiation retinopathy and optic neuropathy. Little is known about the dose–response relationship and patient characteristics. We aimed to systematically review the prevalence of radiation retinopathy and optic neuropathy. Method: The primary outcome was the pooled prevalence of radiation retinopathy and optic neuropathy. The secondary outcome included the effect of the total radiation dose prescribed for the tumor according to the patient’s characteristics. Furthermore, we aimed to evaluate the radiation dose parameters for organs at risk of radiation retinopathy and optic neuropathy. Results: The pooled prevalence was 3.8%. No retinopathy was reported for the tumor’s prescribed dose of 50 Gy than <50 Gy. We observed a higher prevalence rate for retinopathy (6.0%) than optic neuropathy (2.0%). Insufficient data on the dose for organs at risk were reported. Conclusion: The prevalence of radiation retinopathy was higher compared to optic neuropathy. This review emphasizes the need for future studies considering retinopathy and optic neuropathy as primary objective parameters.

1 February 2024 in Brachytherapy
Verified
Journal Article
Open access
LDLeah R.M. Dickhoff
Leah R.M. Dickhoff
RSRenzo J. Scholman
Renzo J. Scholman
DBDanique L.J. Barten
Danique L.J. Barten
EKEllen M. Kerkhof
Ellen M. Kerkhof
JRJelmen J. Roorda
Jelmen J. Roorda
TATanja Alderliesten
Tanja Alderliesten
Without a clear definition of an optimal treatment plan, no optimization model can be perfect. Therefore, instead of automatically finding a single "optimal" plan, finding multiple, yet different near-optimal plans, can be an insightful approach to support radiation oncologists in finding the plan they are looking for. BRIGHT is a flexible AI-based optimization method for brachytherapy treatment planning that has already been shown capable of finding high-quality plans that trade-off target volume coverage and healthy tissue sparing. We leverage the flexibility of BRIGHT to find plans with similar dose-volume criteria, yet different dose distributions. We further describe extensions that facilitate fast plan adaptation should planning aims need to be adjusted, and straightforwardly allow incorporating hospital-specific aims besides standard protocols. Results are obtained for prostate (n = 12) and cervix brachytherapy (n = 36). We demonstrate the possible differences in dose distribution for optimized plans with equal dose-volume criteria. We furthermore demonstrate that adding hospital-specific aims enables adhering to hospital-specific practice while still being able to automatically create cervix plans that more often satisfy the EMBRACE-II protocol than clinical practice. Finally, we illustrate the feasibility of fast plan adaptation. Methods such as BRIGHT enable new ways to construct high-quality treatment plans for brachytherapy while offering new insights by making explicit the options one has. In particular, it becomes possible to present to radiation oncologists a manageable set of alternative plans that, from an optimization perspective are equally good, yet differ in terms of coverage-sparing trade-offs and shape of the dose distribution.

1 January 2023 in Journal of Medical Imaging
Verified
Journal Article
Open access
PDF file
MGMonika Grewal
Monika Grewal
JWJan Wiersma
Jan Wiersma
HWHenrike Westerveld
Henrike Westerveld
PBPeter A. N. Bosman
Peter A. N. Bosman
TATanja Alderliesten
Tanja Alderliesten
Deformable image registration (DIR) is a task of aligning a source (or moving) image to a target (or fixed) image by optimizing a displacement vector field. The aligned source image can then be computed by resampling the source image at the spatial locations specified by the mapping. DIR has tremendous application possibilities in the radiation treatment workflow required for cancer treatment e.g., automatic contour propagation,1,2 dose accumulation.3 – 5 However, DIR in regions such as the pelvis is challenging due to large local deformations and appearance differences caused by physical processes such as bladder filling, and the presence of gas pockets and contrast agents.2 In such DIR scenarios, the existing non-linear intensity-based registration approaches6 – 8 often get stuck in a local minimum.4 Many previous studies9 – 14 have shown that landmark correspondences between the images to be registered can provide additional guidance to the intensity-based DIR methods and help overcome local minima. However, to the best of our knowledge, such an approach has not been tested on pelvic scans.