Robin Diekmann

Robin Diekmann

Auto-generated profile, based on publicly available information

Robin Diekmann

Cell Biology and Biophysics Unit, European Molecular Biology Laboratory (EMBL), Heidelberg, Germany

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2017 in Nature Photonics
Verified
Journal Article
Closed access
RDRobin Diekmann
Robin Diekmann
ØHØystein I. Helle
Øystein I. Helle
CØCristina I. Øie
Cristina I. Øie
PMPeter McCourt
Peter McCourt
THThomas Huser
Thomas Huser
BABalpreet S. Ahluwalia
Balpreet S. Ahluwalia

17 August 2020 in Nature Methods
Verified
Journal Article
Closed access
PDF file
RDRobin Diekmann
Robin Diekmann
MKMaurice Kahnwald
Maurice Kahnwald
ASAndreas Schoenit
Andreas Schoenit
JDJoran Deschamps
Joran Deschamps
UMUlf Matti
Ulf Matti
JRJonas Ries
Jonas Ries

13 December 2016 in Nature Communications
Verified
Journal Article
Open access
RDRobin Diekmann
Robin Diekmann
DWDeanna L. Wolfson
Deanna L. Wolfson
CSChristoph Spahn
Christoph Spahn
MHMike Heilemann
Mike Heilemann
MSMark Schüttpelz
Mark Schüttpelz
THThomas Huser
Thomas Huser
Imaging non-adherent cells by super-resolution far-field fluorescence microscopy is currently not possible because of their rapid movement while in suspension. Holographic optical tweezers (HOTs) enable the ability to freely control the number and position of optical traps, thus facilitating the unrestricted manipulation of cells in a volume around the focal plane. Here we show that immobilizing non-adherent cells by optical tweezers is sufficient to achieve optical resolution well below the diffraction limit using localization microscopy. Individual cells can be oriented arbitrarily but preferably either horizontally or vertically relative to the microscope’s image plane, enabling access to sample sections that are impossible to achieve with conventional sample preparation and immobilization. This opens up new opportunities to super-resolve the nanoscale organization of chromosomal DNA in individual bacterial cells.

16 December 2020 in Nature Protocols
Verified
Journal Article
Closed access
PDF file
JWJingyu Wang
Jingyu Wang
EAEdward S. Allgeyer
Edward S. Allgeyer
GSGeorge Sirinakis
George Sirinakis
YZYongdeng Zhang
Yongdeng Zhang
KHKevin Hu
Kevin Hu
JBJoerg Bewersdorf
Joerg Bewersdorf

31 October 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
RDRobin Diekmann
Robin Diekmann
KTKatharina Till
Katharina Till
MMMarcel Müller
Marcel Müller
MSMatthias Simonis
Matthias Simonis
MSMark Schüttpelz
Mark Schüttpelz
THThomas Huser
Thomas Huser
Many commercial as well as custom-built fluorescence microscopes use scientific-grade cameras that represent a substantial share of the instrument’s cost. This holds particularly true for super-resolution localization microscopy where high demands are placed especially on the detector with respect to sensitivity, noise, and also image acquisition speed. Here, we present and carefully characterize an industry-grade CMOS camera as a cost-efficient alternative to commonly used scientific cameras. Direct experimental comparison of these two detector types shows widely similar performance for imaging by single molecule localization microscopy (SMLM). Furthermore, high image acquisition speeds are demonstrated for the CMOS detector by ultra-fast SMLM imaging.

19 December 2018 in Nature Communications
Verified
Journal Article
Open access
PDF file
AAArash Ahmadi
Arash Ahmadi
IRIda Rosnes
Ida Rosnes
PBPernille Blicher
Pernille Blicher
RDRobin Diekmann
Robin Diekmann
MSMark Schüttpelz
Mark Schüttpelz
ARAlexander D. Rowe
Alexander D. Rowe
In order to preserve genomic stability, cells rely on various repair pathways for removing DNA damage. The mechanisms how enzymes scan DNA and recognize their target sites are incompletely understood. Here, by using high-localization precision microscopy along with 133 Hz high sampling rate, we have recorded EndoV and OGG1 interacting with 12-kbp elongated λ-DNA in an optical trap. EndoV switches between three distinct scanning modes, each with a clear range of activation energy barriers. These results concur with average diffusion rate and occupancy of states determined by a hidden Markov model, allowing us to infer that EndoV confinement occurs when the intercalating wedge motif is involved in rigorous probing of the DNA, while highly mobile EndoV may disengage from a strictly 1D helical diffusion mode and hop along the DNA. This makes EndoV the first example of a monomeric, single-conformation and single-binding-site protein demonstrating the ability to switch between three scanning modes.