Case description: Five workers (2 males and 3 females) employed in a furniture factory located in eastern Poland developed hypersensitivity pneumonitis (HP) after the pine wood used for furniture production was replaced by birch wood. All of them reported onset of respiratory and general...
19 December 2019 in Annals of Agricultural and Environmental Medicine
Thiram, a fungicides, is widely used on seeds and as foliar agent on turf, vegetables and fruit. It is also used in the rubber industry as a vulcanization accelerator. When absorbed through the respiratory system, it is rapidly metabolised to dimethylthiocarbamate and carbon disulphide, causing noxious effects. A brief review is presented of the literature, centering on the interesting case of a 45-year-old woman admitted to the hospital suffering from acute respiratory failure. Computer tomography in angiographic option (angio-CT) showed an extensive, irregular area of ground glass in both upper lobes and apical segments of the lower lobes of the lungs. A significant enlargement of both atria was also described. There was no improvement after cardiac treatment and patient was transferred to the pulmonary department where she was succesfully treated with systemic glucocortycosteroids. The patient remains under the supervision of the pulmonary out-patient department.
Background: The electrodes of implantable cardiac devices (ICDs) may cause significant problems in cardiac computed tomography (CT) because they are a source of artifacts that obscure surrounding structures and possible pathology. There are a few million patients currently with ICDs, and some of these patients will require cardiac imaging due to coronary artery disease or problems with ICDs. Modern CT scanners can reduce some of the metal artifacts because of MAR software, but in some vendors, it does not work with ECG gating. Introduced in 2008, dual-energy CT scanners can generate virtual monoenergetic images (VMIs), which are much less susceptible to metal artifacts than standard CT images. Objective: This study aimed to evaluate if dual-energy CT can reduce metal artifacts caused by ICD leads by using VMIs. The second objective was to determine how the angle between the electrode and the plane of imaging affects the severity of the artifacts in three planes of imaging. Methods: A 3D-printed model was constructed to obtain a 0–90-degree field at 5-degree intervals between the electrode and each of the planes: axial, coronal, and sagittal. This electrode was scanned in dual-energy and single-energy protocols. VMIs with an energy of 40–140 keV with 10 keV intervals were reconstructed. The length of the two most extended artifacts originating from the tip of the electrode and 2 cm above it—at the point where the thick metallic defibrillating portion of the electrode begins—was measured. Results: For the sagittal plane, these observations were similar for both points of the ICDs that were used as the reference location. VMIs with an energy over 80 keV produce images with fewer artifacts than similar images obtained in the single-energy scanning mode. Conclusions: Virtual monoenergetic imaging techniques may reduce streak artifacts arising from ICD electrodes and improve the quality of the image. Increasing the angle of the electrode as well as the imaging plane can reduce artifacts. The angle between the electrode and the beam of X-rays can be increased by tilting the gantry of the scanner or lifting the upper body of the patient.