Jehanzeb Shahid

Jehanzeb Shahid

Auto-generated profile, based on publicly available information

Jehanzeb Shahid

Department of Radiology, Aga Khan University Hospital, Karachi, Pakistan

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2022 in Radiology Case Reports
Verified
Journal Article
Open access
MAMuhammad Azeemuddin
Muhammad Azeemuddin
AKAnosha Khan
Anosha Khan
IAIflah Ansari
Iflah Ansari
JSJehanzeb Shahid
Jehanzeb Shahid
FKFaheemullah Khan
Faheemullah Khan
TKTaif Khattak
Taif Khattak
Fracture and migration of port-a-catheter, following long term access into the central venous vasculature is a rare clinical scenario. The consequences of fracture and migration includes fragmented device relocating into the right atrium or ventricle, eventually causing life threatening complications such as arrhythmias, pseudoaneurysms, perforations or very rarely embolization. We report a case of a 67-year-old female with a broken port-a-catheter which had been placed initially for chemotherapy for bilateral breast cancer. Chest radiograph showed the fragmented catheter had migrated to the right atrium; which was successfully removed via percutaneous radiological endovascular intervention. No immediate post procedure complication was noted.

1 April 1992 in Contraception
Verified
Journal Article
Closed access
TNT.D. Nandedkar
T.D. Nandedkar
JSJ.K. Shahid
J.K. Shahid
SKS.D. Kholkute
S.D. Kholkute
MDM.B. Darpe
M.B. Darpe
SMS.B. Moodbidri
S.B. Moodbidri

26 August 2023 in Radiology Case Reports
Verified
Journal Article
Open access
MSMuhammad Ibrahim Saeed
Muhammad Ibrahim Saeed
ABAmna Subhan Butt
Amna Subhan Butt
JSJahanzeb Shahid
Jahanzeb Shahid
JIJunaid Iqbal
Junaid Iqbal
Upper gastrointestinal bleeding (UGIB) carries a high risk of morbidity and mortality despite recent improvements in diagnosis and management. Many patients failed to respond to initial endoscopic and medical management. Transcatheter arterial embolization (TAE) is now considered the next line of therapy over surgery in refractory UGIB because of its good safety profile and high technical and clinical success rate. We discuss the case of a 66-year-old female patient who presented with massive UGIB and had TAE after endoscopic hemostasis failed. She developed widespread ischemia involving multiple organs following the procedure, including the liver, gallbladder, pancreas, spleen, and small intestine, as a result of an abnormal communication between the gastroduodenal artery (GDA) and superior mesenteric artery (SMA), resulting in PVA particle reflux and widespread ischemic injury. It is important to carefully evaluate the vascular anatomic variations before the procedure to avoid potential complications of ischemia.

15 January 2021 in bioRxiv
Verified
Preprint
Open access
PDF file
KHKiran Hilal
Kiran Hilal
JSJehanzeb Shahid
Jehanzeb Shahid
AAAbdullah Ameen
Abdullah Ameen
RMRussell Martins
Russell Martins
ANAvinash Nankani
Avinash Nankani
AAAinan Arshad
Ainan Arshad
Introduction Various CT severity scores have already been described in literature since the start of this pandemic. One pertinent issue with all of the previously described severity scores is their relative challenging calculation and variance in inter-observer agreement. The severity score proposed in our study is relatively simpler, easier to calculate and apart from a trained radiologist, can easily be calculated even by physicians with good inter-observer agreement. Therefore, a rapid CT severity score calculation can give a clue to physician about possible clinical outcome without being dependent on radiologist who may not be readily available especially in third world countries. Objective The objective of this study is to develop a simple CT severity score (CT-SS) with good inter-observer agreement and access its correlation with clinical outcome. Methods This retrospective study was conducted by the Department of Radiology and Internal Medicine, at the Aga Khan University Hospital Karachi, from April 2020 to August 2020. Non-probability consecutive sampling was used to include all patients who were positive for COVID-19 on PCR, and underwent CT chest examination at AKUH. Severity of disease was calculated in each lobe on the basis of following proposed CT severity scoring system (CT-SS). For each lobe the percentage of involvement by disease was scored – 0% involvement was scored 0, 50% involvement was scored 2. Maximum score for one lobe was 2 and hence total maximum overall score for all lobes was 10. Continuous data was represented using mean and standard deviation, and compared using independent sample t-tests. Categorical data was represented using frequencies and percentages, and compared using Chi-squared tests. Inter-observer reliability between radiologist and COVID intensivist for the 10 point CT-SS rated on 0-10 was assessed using the Kappa statistic. A p-value < 0.05 was considered significant for all analyses. Results A total of 73 patients were included, the majority male (58.9%) with mean age 55.8 ± 13.93 years. The CT-SS rated on 0-10 showed substantial inter-observer reliability between radiologist and intensivist with a Kappa statistic of 0.78. Patients with CT-SS 8-10 had a significantly higher ICU admission & intubation rate (53.8% vs. 23.5%) and mortality rate (35.9% vs. 11.8%; p = 0.017), as compared to those with CT-SS 0-7. Conclusion We conclude that the described CT severity score (CT-SS) is a quick, effective and easily reproducible tool for prediction of adverse clinical outcome in patients with COVID 19 pneumonia. The tool shows good inter-observer agreement when calculated by radiologist and physician independently.