Michael D. Rivers-Bowerman

Michael D. Rivers-Bowerman

Auto-generated profile, based on publicly available information

Michael D. Rivers-Bowerman

Faculty of Medicine, Dalhousie University, Halifax, NS, Canada

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2020 in RadioGraphics
Verified
Journal Article
Closed access
LFLaura A. Fitzpatrick
Laura A. Fitzpatrick
MRMichael D. Rivers-Bowerman
Michael D. Rivers-Bowerman
STSeng Thipphavong
Seng Thipphavong
SCSharon E. Clarke
Sharon E. Clarke
JRJudy A. Rowe
Judy A. Rowe
ACAndreu F. Costa
Andreu F. Costa
Acute mesenteric ischemia is a life-threatening condition with a high mortality rate and is challenging to diagnose because patient symptoms and laboratory test results are often nonspecific. Acute mesenteric ischemia (AMI) is a life-threatening condition with a high mortality rate. The diagnosis of AMI is challenging because patient symptoms and laboratory test results are often nonspe...

1 September 2014 in Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques
Verified
Journal Article
Open access
PDF file
MRMichael D. Rivers-Bowerman
Michael D. Rivers-Bowerman
JSJai Shankar
Jai Shankar
Background: Iterative reconstruction has been reported to reduce radiation dose in CT, while preserving and even improving image quality. The purpose of this study was to evaluate the effects of sinogram-affirmed iterative reconstruction (SAFIRE) on radiation dose reduction and image quality for noncontrast adult head CT and to compare SAFIRE with conventional filtered back-projection (FBP) reconstruction.Methods: Institutional review board approval was obtained for this retrospective analysis of head CT scans reconstructed with SAFIRE and/or FBP for 107 patients. Radiation dose parameters were recorded from scanner-generated CT dose reports. Signal-to-noise and contrast-to-noise ratios (SNR, CNR) were calculated from gray and white matter (GM, WM) attenuation measurements. Image noise, artifacts, GM-WM differentiation, small structure visibility, and sharpness were graded by two readers. Statistical analysis included the independent-samples t test for quantitative data, the related samples Wilcoxon signed-rank test for qualitative data, the coefficient of repeatability for intraobserver variation, and κ statistics for interobserver agreement.Results: Mean effective dose was significantly reduced with SAFIRE from 2.0 to 1.7 mSv (p<0.0001). SAFIRE also significantly improved GM SNR, WM SNR, and GM-WM CNR (p<0.0001). Significant reductions in image noise and posterior fossa artifact as well as improvements in GM-WM differentiation, small structure visibility, and sharpness were noted with SAFIRE (P<0.005).Conclusions: SAFIRE for noncontrast adult head CT reduces patient radiation dose by 15% for the settings employed at our institution, while significantly improving multiple quantitative and qualitative measures of image quality.

1 September 2017 in Radiology Case Reports
Verified
Journal Article
Open access
MRMichael D. Rivers-Bowerman
Michael D. Rivers-Bowerman
CLChristopher B. Lightfoot
Christopher B. Lightfoot
RMRuairi P. Meagher
Ruairi P. Meagher
MCMichael Carter
Michael Carter
RBRobert F. Berry
Robert F. Berry
A 50-year-old male with right upper quadrant symptoms and hepatic dysfunction was found to have multiple dilated hepatic veins (HVs) with intrahepatic collateralization and membranous occlusion of the intrahepatic inferior vena cava (IVC) consistent with primary Budd-Chiari syndrome. Venacavograms depicted drainage of the intrahepatic collaterals through a left-sided HV entering the IVC above the level of the occlusion. Sharp recanalization of the membranous IVC occlusion was performed with an occlusion balloon as a needle target under echocardiographic monitoring followed by balloon angioplasty with restoration of IVC patency. Clinical, laboratory, and venographic procedural success has been demonstrated to 9 months with minimal residual stenosis.

1 March 2017 in Radiology Case Reports
Verified
Journal Article
Open access
MRMichael D. Rivers-Bowerman
Michael D. Rivers-Bowerman
SLSharon Litz
Sharon Litz
PSPierre Schmit
Pierre Schmit
Cerebral venous air embolism is a relatively rare condition that arises from iatrogenic or traumatic introduction of air into the venous system. We describe the ultrasonographic findings in a 1-day-old infant with iatrogenic retrograde cerebral venous air embolism, which to our knowledge, is the earliest case reported in the literature to date. This case highlights the role of cerebral ultrasonography in the detection and surveillance of cerebral venous air embolism in neonates.

31 January 2026 in Canadian Association of Radiologists Journal
Verified
Journal Article
Open access
JTJessica Thompson
Jessica Thompson
JSJoseph Silburt
Joseph Silburt
SSStephanie Schofield
Stephanie Schofield
ACAndreu F. Costa
Andreu F. Costa
MRMichael Rivers-Bowerman
Michael Rivers-Bowerman
Introduction: The carbon footprint of imaging equipment in radiology is high, but the impact of patient travel for imaging is unclear. This study aimed to quantify distances traveled by ambulatory patients for outpatient MRI, determine the proportion traveling beyond their nearest MRI facility, and estimate the associated excess carbon dioxide equivalent (CO 2 e) emissions. Methods: With research ethics board approval, we retrospectively analyzed provincial MRI data from 2023. Distances from patient home address to the nearest and attended MRI facilities were calculated. CO 2 e estimates were derived using an online tool ( www.carbonfootprint.com/calculator.aspx ) with average vehicle size and emissions. Results: In 2023, 40 062 provincial MRI scans were performed; isolating single visits for adult patients yielded 27 755 data points. Of these, 19.5% (n = 5400) traveled beyond their nearest MRI facility. Mean round-trip travel was 60.4 km for those attending their nearest site versus 295.6 km for those traveling further ( P < .0001). The excess travel produced ~288 metric tons of additional CO 2 e, equivalent to emissions from 61 large-size gasoline-powered cars driven for 1 year or carbon sequestered by 4762 tree seedlings grown for 10 years. Conclusion: Nearly one-fifth of patients traveled farther than necessary for MRI, generating substantial avoidable emissions. Aligning MRI service distribution with population density could lessen the environmental impact of medical imaging.