Oleksandr Hapon

Oleksandr Hapon

Auto-generated profile, based on publicly available information

Oleksandr Hapon

Municipal enterprise Kyiv city clinical hospital № 6, Ukraine

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 October 2021 in Klinicheskaia khirurgiia
Verified
Journal Article
Open access
PDF file
GHG. I. Herzen
G. I. Herzen
VKV. V. Kryzhevskyi
V. V. Kryzhevskyi
AGA. N. Gapon
A. N. Gapon
AMA. S. Movchan
A. S. Movchan
SDS. V. Dibkalyuk
S. V. Dibkalyuk
ROR. N. Ostapchuk
R. N. Ostapchuk
Objective. To estimate the results of operative treatment of clavicular fractures in middle one third with fragments shifted, using the closed method with application of intramedullary elastic titanic compressing rod. Materials and methods. In the Department of Orthopedics and Traumatology of Kyiv Municipal Clinical Hospital No. 6 («Medgorodok») in 38 patients ageing 18 - 67 yrs with the closed clavicular fractures in middle one third with shifted fragments the closed intramedullary osteosynthesis, using elastic titanic compressing rod, was performed. Methods of the patients examination, indication s for operative treatment, its technique, late results of the operation were studied. Results. While estimating late results in 12 mo postoperatively in accordance to Constant Score (estimation of the brachial joint function) there were (97.1 ± 3.5) points of 100 possible points noted at average. In all the patients the movements in brachial joint were free and painless, they served themselves completely while doing solemn round of industry, coming back to their ordinary profession activity and sport. Conclusion. Intramedullary osteosynthesis of clavicular fractures in middle one third, using elastic titanic compressing rod as method of operative treatment, may guarantee satisfactory late results.

23 October 2026 in The Ukrainian Journal of Clinical Surgery
Verified
Journal Article
Open access
HHH. I. Hercen
H. I. Hercen
ROR. I. Opryshchenko
R. I. Opryshchenko
OHO. M. Hapon
O. M. Hapon
HBH. H. Bilonogkin
H. H. Bilonogkin
Objective. To investigate and compare the recovery of shoulder girdle muscle function following metal osteosynthesis of displaced fractures of the clavicle body (type 15.2AB according to the AO/ASIF classification) using a compression rod, a contoured LCP plate or a Bogdanov rod, based on electromyography data.Materials and methods. In 30 patients with displaced fractures of the clavicle body classified as type 15.2AB according to the AO/ASIF classification, the recovery of upper limb muscle function was assessed over a 1-year period following metal osteosynthesis using an LCP contoured plate, a compression rod and a Bogdanov rod, the recovery of upper limb muscle function was assessed using electromyography. Patients were examined on the 30th day, and 3 and 12 months after surgery. The functional status of the upper limb muscles (deltoid, pectoralis major, infraspinatus and trapezius) of the operated limb was assessed and compared with the functional status of the corresponding muscles of the shoulder girdle on the healthy limb using surface (interferential) electromyography on the M-TEST 2 device (DX-Systems, Ukraine). The bioelectrical activity of the muscles was assessed using the following parameters: maximum amplitude, mean spectral frequency and asymmetry coefficient. The data obtained were interpreted using licensed software from DX-Systems (Ukraine).Results. Analysis of the early rehabilitation period (1 month post-operation) revealed the advantages of metal osteosynthesis of displaced clavicle shaft fractures using a compression rod: the maximum amplitude of the deltoid muscle was (290.2 ± 14.3) μV. The results of metal osteosynthesis of clavicle shaft fractures using a contoured LCP plate and a Bogdanov rod were poorer: the maximum amplitude values of the deltoid muscle were (220.4 ± 15.1) and (235.5 ± 16.8) μV, respectively (p < 0.05). By the third month of the rehabilitation period, a ‘critical point’ was identified in relation to metal-osteosynthesis of clavicle shaft fractures using a Bogdanov pin: the subscapularis muscle deficit was (210 ± 19.2) μV and was the highest (p < 0.05) among the corresponding values when other methods of metal osteosynthesis were used. Twelve months after metal osteosynthesis of clavicle shaft fractures using a contoured LCP plate and a compression rod, good, practically adapted function of the shoulder girdle muscles was established based on the maximum amplitude and average frequency of the spectrum. In contrast, in patients who underwent metal osteosynthesis of clavicle shaft fractures using a Bogdanov rod, incomplete adaptation of the shoulder girdle muscle function was observed. The maximum amplitude and mean frequency of the spectrum for the subscapularis muscle were , (340.1 ± 24.5) µV and (68 ± 3.1) Hz respectively; that is, they were low, which objectively indicated its atrophy.Conclusions. Following intramedullary metal osteosynthesis of displaced clavicle shaft fractures using a compression rod, electromyography data indicate that the conditions for early recovery of upper limb muscle function are better than after metal osteosynthesis using a contoured LCP plate and a Bogdanov rod.

28 June 2026 in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
Verified
Journal Article
Open access
PDF file
HHHenrich Hercen
Henrich Hercen
OHOleksandr Hapon
Oleksandr Hapon
HBHennadii Bilonozhkin
Hennadii Bilonozhkin
Objective. To study the effectiveness of osteosynthesis of unstable clavicle fractures of type 15.2AB using a compressive rod based on biomechanical studies. Methods. Biomechanical studies analysed the results of computer experimental studies, as well as finite element method data. In the conditions of modelling o steosynthesis o f u nstable c lavicle f ractures 1 5.2AB, he strength characteristics of the compression rod were taken into account in comparison with the traditional intramedullary Bogdanov rod. Computer modelling analysed studies that used clavicle models created using the finite element method (FEM). These models made it possible to assess the distribution of stresses and deformations in the clavicle and fixing elements under different types of loads. Parameters such as maximum stress in the implant and bone, as well as interfragmentary displacement, were measured. Results. Biomechanical studies of osteosynthesis modelling of unstable clavicle fractures OTA 15.2AB showed the advantages of a compression rod compared to the traditional Bogdanov intramedullary rod in terms of the maximum load required for deformation, implant failure, as well as creating greater stability of clavicle osteosynthesis during its torsion and bending. Thus, the bending stiffness of the compression rod was 1.3-1.4 times higher, and the torsional stiffness was 1.3 times higher (p < 0.05). The load to deformation and destruction of the compressive rod was also 1.3–1.6 times higher (p < 0.05). The maximum displacement of clavicle fragments with the compressive rod was 0.7–0.8 times less compared to the Bogdanov rod. Conclusions. After osteosynthesis of unstable clavicle body fractures 15.2AB with a compressive rod, its strength characteristics have advantages over Bogdanov’s rod in terms of deformation, implant destruction, and higher stability of clavicle fragments during bending and torsion due to a more uniform pressure distribution.

25 April 2024 in TRAUMA
Verified
Journal Article
Open access
PDF file
HHH.I. Hercen
H.I. Hercen
OHO.M. Hapon
O.M. Hapon
HBH.H. Bilonozhkin
H.H. Bilonozhkin
Despite the favorable prognosis of conservative treatment for clavicle fractures, unsatisfactory consequences reach 10–30 % cases. Surgical methods of treatment for dislocated clavicle fractures, such as osteosynthesis with a plate or an elastic titanium rod, are mostly used in practice. The disadvantage of the latter is the possible migration of the implant with perforation of the skin. The purpose was to study the effectiveness of an intramedullary rod, improved by us, for osteosynthesis of dislocated clavicle fractures type OTA 15A and OTA 15B according to the AO/ASIF classification. The essence of the improvement was the possibility of closed minimally invasive intramedullary osteosynthesis of the clavicle body, with a simplified technique of the surgical intervention itself, prevention of implant migration. The latter was achieved by the fact that one of the ends of the rod had a drill, which eliminated the need for predrilling the medullary cavity of the clavicle to insert the rod, and its opposite end had a thread onto which a nut is screwed to achieve compression between the clavicular fragments. Forty-two patients with closed dislocated clavicle fractures were under supervision in the clinic of traumatology and orthopedics of Kyiv City Clinical Hospital 6. They underwent intramedullary osteosynthesis for clavicle fractures with an improved compressing rod (closed in 28 cases, open in 14) under regional anesthesia. In dyna-mics of the postoperative period, a clinical and radiological examination was performed, the severity of the pain syndrome and the function of the upper limb were assessed according to the visual analog scale (VAS), Disability of Arm, Shoulder and Hand (DASH). As shown by the results of X-ray examinations, the average period of clavicle fracture union was 10.1 ± 1.4 weeks (range 8–12 weeks). During the observation of the patients, favorable dynamics on the VAS and DASH were noted; by the end of the study (12 months after the operation), the functional capabilities of the upper limb on the DASH corresponded to 1.54 ± 0.84 points, VAS score was 9.60 ± 2.11 points. The improved construction of the intramedullary rod for osteosynthesis of dislocated clavicle fractures of the OTA 15A and OTA 15B type can be recommended for use in practice, as it has demonstrated favorable clinical, radiological, and functional outcomes.