1 June 2014 in Soft Robotics
Most devices for single-site or natural orifice transluminal surgery are very application specific and, hence, capable of effectively carrying out specific surgical tasks only. However, most of these instruments are rigid, lack a sufficient number of degrees of freedom (DOFs), and/or are incapable of modifying their mechanical properties based on the tasks to be performed. The current philosophy in commercial instrument design is mainly focused on creating minimally invasive surgical systems using rigid tools equipped with dexterous tips. Only few research efforts are aimed at developing flexible surgical systems, with many DOFs or even continuum kinematics. The authors propose a radical change in surgical instrument design: away from rigid tools toward a new concept of soft and stiffness-controllable instruments. Inspired by biology, we envision creating such soft and stiffness-controllable medical devices using the octopus as a model. The octopus presents all the capabilities requested and can be viewed as a precious source of inspiration. Several soft technologies are suitable for meeting the aforementioned capabilities, and in this article a brief review of the most promising ones is presented. Then we illustrate how specific technologies can be applied in the design of a novel manipulator for flexible surgery by discussing its potential and by presenting feasibility tests of a prototype responding to this new design philosophy. Our aim is to investigate the feasibility of applying these technologies in the field of minimally invasive surgery and at the same time to stimulate the creativeness of others who could take the proposed concepts further to achieve novel solutions and generate specific application scenarios for the devised technologies.
13 May 2015 in Bioinspiration & Biomimetics
This paper introduces a novel, bioinspired manipulator for minimally invasive surgery (MIS). The manipulator is entirely composed of soft materials, and it has been designed to provide similar motion capabilities as the octopus's arm in order to reach the surgical target while exploiting its whole length to actively interact with the biological structures. The manipulator is composed of two identical modules (each of them can be controlled independently) with multi-directional bending and stiffening capabilities, like an octopus arm. In the authors' previous works, the design of the single module has been addressed. Here a two-module manipulator is presented, with the final aim of demonstrating the enhanced capabilities that such a structure can have in comparison with rigid surgical tools currently employed in MIS. The performances in terms of workspace, stiffening capabilities, and generated forces are characterized through experimental tests. The combination of stiffening capabilities and manipulation tasks is also addressed to confirm the manipulator potential employment in a real surgical scenario.
20 January 2016 in IEEE Transactions on Robotics
This paper presents the concept design of a modular soft manipulator for minimally invasive surgery. Unlike traditional surgical manipulators based on metallic steerable needles, tendon-driven mechanisms, or articulated motorized links, we combine flexible fluidic actuators to obtain multidirectional bending and elongation with a variable stiffness mechanism based on granular jamming. The idea is to develop a manipulator based on a series of modules, each consisting of a silicone matrix with pneumatic chambers for 3-D motion, and one central channel for the integration of granular-jamming-based stiffening mechanism. A bellows-shaped braided structure is used to contain the lateral expansion of the flexible fluidic actuator and to increase its motion range. In this paper, the design and experimental characterization of a single module composed of such a manipulator is presented. Possible applications of the manipulator in the surgical field are discussed.
1 December 2014 in Soft Robotics
The design of a pneumatically actuated silicone module, resembling soft tissue, with three pneumatic chambers is considered and optimized in this study with the aim of using it in a soft robot arm for robotic surgery applications. Three types of silicone materials, Ecoflex 0030 and 0050 and Dragonskin 0030, have been investigated, and a constitutive model has been derived for each of them. Design optimization of the silicone module was based on finite element analysis (FEA) that was validated against experimental data of one-degree bending under one-channel actuation. This was followed by FEA parametric studies for module design optimization to minimize the ballooning effect in one-degree bending as well as reduce the actuation pressure. Modules made from Ecoflex 0030 and Ecoflex 0050 exhibited the same bending shape in FEA, but about three times higher actuation pressure was required for the harder Ecoflex 0050. Design parameters under investigation in the parametric FEA studies included the shape of the pneumatic channel cross section, the ratio of channel length to module length, the distance of channel from the module wall, and the ratio of channel to module cross-sectional area. After FEA design optimization yielded least ballooning for pneumatic chambers of semicircular cross section, an internal dragonskin structure was added internally below the module surface to enable and guide the bending under one-channel pneumatic actuation and further contain the ballooning effect: the benefits of this design were successfully verified under both FEA and experimental analysis
6 November 2015 in Smart Materials and Structures
This paper introduces a pose-sensing system for soft robot arms integrating a set of macrobend stretch sensors. The macrobend sensory design in this study consists of optical fibres and is based on the notion that bending an optical fibre modulates the intensity of the light transmitted through the fibre. This sensing method is capable of measuring bending, elongation and compression in soft continuum robots and is also applicable to wearable sensing technologies, e.g. pose sensing in the wrist joint of a human hand. In our arrangement, applied to a cylindrical soft robot arm, the optical fibres for macrobend sensing originate from the base, extend to the tip of the arm, and then loop back to the base. The connectors that link the fibres to the necessary opto-electronics are all placed at the base of the arm, resulting in a simplified overall design. The ability of this custom macrobend stretch sensor to flexibly adapt its configuration allows preserving the inherent softness and compliance of the robot which it is installed on. The macrobend sensing system is immune to electrical noise and magnetic fields, is safe (because no electricity is needed at the sensing site), and is suitable for modular implementation in multi-link soft continuum robotic arms. The measurable light outputs of the proposed stretch sensor vary due to bend-induced light attenuation (macrobend loss), which is a function of the fibre bend radius as well as the number of repeated turns. The experimental study conducted as part of this research revealed that the chosen bend radius has a far greater impact on the measured light intensity values than the number of turns (if greater than five). Taking into account that the bend radius is the only significantly influencing design parameter, the macrobend stretch sensors were developed to create a practical solution to the pose sensing in soft continuum robot arms. Henceforward, the proposed sensing design was benchmarked against an electromagnetic tracking system (NDI Aurora) for validation.